UNION CARBIDE CORP -- CARBOWAX POLYETHYLENE GLYCOL, 1450 FLAKE
=======================================================
Material Safety Data Sheet
=======================================================
MSDS Num: BWDMP
MSDS NAME: CARBOWAX POLYETHYLENE GLYCOL, 1450 FLAKE
Responsible Party
Name: UNION CARBIDE CORP
Address: 39 OLD RIDGEBURY RD
City: DANBURY CT 06817-0001
Info Phone: 304-744-3487
Emergency Phone Number: 800-822-4357
Published: Y
=======================================================
Contractor Summary
=======================================================
Name: UNION CARBIDE CORP LINDE DIV
Address: 39 OLD RIDGEBURY RD
City: DANBURY CT 06817-0001
Phone: 800-822-4357; 304-744-3487
=======================================================
Ingredients
=======================================================
Cas: 25322-68-3
RTECS #: TQ3500000
Name: POLYETHYLENE GLYCOL
% Wt: 100
OSHA PEL: N/K (FP N)
ACGIH TLV: N/K (FP N)
------------------------------
Cas: 75-07-0
RTECS #: AB1925000
Name: ACETALDEHYDE (SARA III)
% Wt: 0.0006
OSHA PEL: 200 PPM
ACGIH TLV: 25 PPM, C
EPA Rpt Qty: 1000 LBS
DOT Rpt Qty: 1000 LBS
------------------------------
Cas: 123-91-1
RTECS #: JG8225000
Name: P-DIOXANE; (DIOXANE) (SARA III)
% Wt: 0.0005
OSHA PEL: 100 PPM, S
ACGIH TLV: 25 PPM, S
EPA Rpt Qty: 100 LBS
DOT Rpt Qty: 100 LBS
------------------------------
Cas: 75-21-8
RTECS #: KX2450000
Name: ETHYLENE OXIDE (SARA III)
% Wt: 0.0005
OSHA PEL: SEE 1910.1047
ACGIH TLV: 1 PPM
EPA Rpt Qty: 10 LBS
DOT Rpt Qty: 10 LBS
------------------------------
Cas: 50-00-0
RTECS #: LP8925000
Name: FORMALDEHYDE (SARA III)
% Wt: 0.0004
OSHA PEL: SEE 1910.1048
ACGIH TLV: 0.3 PPM, C
EPA Rpt Qty: 100 LBS
DOT Rpt Qty: 100 LBS
------------------------------
Name: SUPP DATA:TO DETERMINE LEVELS OF EXPOSURE TO ETHYLENE OXIDE. IF NEC, PROT
MEASURES SHOULD BE TAKEN.
=======================================================
Health Hazards Data
=======================================================
LD50 LC50 Mixture: NONE SPECIFIED BY MANUFACTURER.
Route Of Entry Inds - Inhalation: YES
Skin: NO
Ingestion: NO
Carcinogenicity Inds - NTP: NO
IARC: NO
OSHA: NO
Effects of Exposure: ACUTE:INGEST/SKIN OR EYE CONT:NO EVID OF HARMFUL EFTS FROM
AVAIL INFO. INHAL:SHORT-TERM HARMFUL EFTS ARE NOT EXPECTED FROM VAP GENERATED
AT AMBIENT TEMP. CHRONIC:ALTHOUGH THIS MATL IS NOT A SKIN IRRIT , SUBMERSION
BY WORKERS OF UNPROTECTED SKIN IN HIGHLY CONCENTRATED SOLNS OF THIS MATL FOR
PRLNG PERIODS(EFTS OF OVEREXP)
Explanation Of Carcinogenicity: NOT RELEVANT
Signs And Symptions Of Overexposure: HLTH HAZ:OF TIME COULD RESULT IN SKIN
DEHYDRATION. OVEREXP TO VAPS GENERATED AT HIGH TEMPS MAY RESULT IN EYE &
RESP TRACT IRRIT, DIZZ, NAUS & INHAL OF HARMFUL AMTS OF MATL. OSHA
CONSIDERS THAT, AT EXC ESS LEVELS, ETHYLENE OXIDE MAY PRESENT REPRO,
MUTAGENIC, GENOTOXIC, NEUROLOGIC & SENSIT HAZS IN HUMANS. IF THIS
(SUPDAT)
Medical Cond Aggravated By Exposure: A KNOWLEDGE OF AVAIL TOXICOLOGY INFO &
OF THE PHYSICAL & CHEM PROPERTIES OF THE MATL SUGGESTS THAT OVEREXP IS
UNLIKELY TO AGGRAVATE EXISTING MEDICAL CONDITIONS.
First Aid: INGEST:CALL MD IMMED (FP N). INHAL:REMOVE TO FRESH AIR. SUPPORT
BRTHG (GIVE O*2/ARTF RESP) (FP N). SKIN:WASH W/SOAP & WATER. EYES:FLUSH
THORO W/WATER FOR AT LST 15 MINS. NOTES TO MD:TOXICOLOGY STUDIES HAVE SHOWN
THIS/SIMILAR MATL TO BE OF VERY LOW ACUTE TOX & NONIRRITATING. THERE IS
NO SPECIFIC ANTIDOTE. TREATMENT OF OVEREXP SHOULD BE DIRECTED AT THE CONTROL
OF SYMPS & CLINICAL CNDTN OF PATIENT.
=======================================================
Handling and Disposal
=======================================================
Spill Release Procedures: COLLECT FOR DISPOSAL.
Neutralizing Agent: NONE SPECIFIED BY MANUFACTURER.
Waste Disposal Methods: THIS PRODUCT IS RESISTANT TO RAPID BIODEGRADATION.
THEREFORE, INCINERATION IS THE PREFERRED METHOD OF DISPOSAL. INCINERATE IN A
FURNACE WHERE PERMITTED UNDER FEDERAL, STATE & LOCAL REGULATIONS.
Handling And Storage Precautions: ATTENTION! USE PRODUCT PROMPTLY AFTER
OPENING. AVOID PROLONGED EXPOSURE TO HEAT & AIR.
Other Precautions: THIS PROD MAY CONTAIN TRACE AMTS OF ETHYLENE OXIDE, CNDTN
WHICH CREATES POTNTL FOR ACCUM OF ETHYLENE OXIDE IN HEAD SPACE OF SHIPPING
& STOR CNTNRS & IN ENCLSD AREAS WHERE PROD IS BEING HNDLD/USED. THI S
PROD MAY NOT BE EXEMPT FROM (SUPDAT)
=======================================================
Fire and Explosion Hazard Information
=======================================================
Flash Point Method: PMCC
Flash Point Text: >350F,>177C
Extinguishing Media: LG FIRES:APPLY ALCOHOL-TYPE/ALL-PURPOSE-TYPE FOAM BY MFR'S
REC TECHNIQUES. SM FIRES:USE CARBON DIOXIDE/DRY CHEM MEDIA.
Fire Fighting Procedures: USE NIOSH/MSHA APPRVD SCBA & FULL PROT EQUIP (FP
N). DO NOT DIRECT SOLID STREAM OF WATER/FOAM INTO HOT, BURNING POOLS; THIS
MAY CAUSE FROTHING & INCR (SUPDAT)
Unusual Fire/Explosion Hazard: NONE.
=======================================================
Control Measures
=======================================================
Respiratory Protection: NIOSH/MSHA APPROVED RESPIRATOR APPROPRIATE FOR EXPOSURE
OF CONCERN (FP N). NONE EXPECTED TO BE NEEDED.
Ventilation: GENERAL (MECHANICAL) ROOM VENTILATION IS EXPECTED TO BE
SATISFACTORY.
Protective Gloves: PVC-COATED GLOVES.
Eye Protection: SAFETY GLASSES OR MONOGOGGLES.
Other Protective Equipment: EYE BATH, SAFETY SHOWER.
Work Hygienic Practices: NONE SPECIFIED BY MANUFACTURER.
Supplemental Safety and Health: BP:>392F,>200C (DECOMPOSES). FIRE FIGHT
PROC:FIRE INTENSITY. MATLS TO AVOID:REACTIVE W/HYDROXYL CMPDS. EFTS OF
OVEREXP:PROD IS HNDLD W/ADEQ VENT, PRESENCE OF THESE TRACE AMTS IS NOT
EXPECTED TO RESULT IN ANY SHORT/LONG TERM HAZ. OTHER PREC:OSHA'S ETHYLENE
OXIDE STD, 29 CFR 1910.1047. USERS SHOULD BE MONITORED
=======================================================
Physical/Chemical Properties
=======================================================
B.P. Text: SUPP DATA
M.P/F.P Text: >109F,>43C
Vapor Pres: NIL
Vapor Density: >1
Spec Gravity: 1.102 (H*2O=1)
Evaporation Rate & Reference: NIL (BUTYL ACETATE=1)
Solubility in Water: 70% BY WT @ 20C.
Appearance and Odor: WHITE FUSED SOLID; MILD ODOR.
=======================================================
Reactivity Data
=======================================================
Stability Indicator: YES
Stability Condition To Avoid: NONE KNOWN.
Materials To Avoid: NORMALLY UNREACTIVE; HOWEVER, AVOID STRONG BASES AT HIGH
TEMPS, STRONG ACIDS, STRONG OXIDIZING AGENTS & MATLS (SUPDAT)
Hazardous Decomposition Products: BURNING CAN PRODUCE THE FOLLOWING COMBUSTION
PRODUCTS: CARBON MONOXIDE &/OR CARBON DIOXIDE.
Hazardous Polymerization Indicator: NO
Conditions To Avoid Polymerization: NOT RELEVANT
=======================================================
Toxicological Information
=======================================================
=======================================================
Ecological Information
=======================================================
=======================================================
MSDS Transport Information
=======================================================
=======================================================
Regulatory Information
=======================================================
=======================================================
Other Information
=======================================================
=======================================================
HAZCOM Label
=======================================================
MSDS NAME: CARBOWAX POLYETHYLENE GLYCOL, 1450 FLAKE
Company: UNION CARBIDE CORP LINDE DIV
Street: 39 OLD RIDGEBURY RD
City: DANBURY CT
Zipcode: 06817-0001
Health Emergency Phone: 800-822-4357
Label Required IND: Y
Date Of Label Review: 12/09/1994
Status Code: C
Label Date: 12/09/1994
Origination Code: G
Chronic Hazard IND: Y
Eye Protection IND: YES
Skin Protection IND: YES
Signal Word: WARNING
Respiratory Protection IND: YES
Health Hazard: Moderate
Contact Hazard: Slight
Fire Hazard: Slight
Reactivity Hazard: None
Hazard And Precautions: ACUTE:INGEST/SKIN OR EYE CONTACT:NO EVIDENCE OF HARMFUL
EFFECTS FROM AVAILABLE INFORMATION. INHAL:SHORT-TERM HARMFUL EFFECTS ARE NOT
EXPECTED FROM VAPOR GENERATED AT AMBIENT TEMPERATURE. OVEREXPOSURE TO VAPOR
GENERATED AT HIGH TEMPERATURESMAY RESULT IN EYE & RESPIRATORY TRACT
IRRITATION, DIZZINESS, NAUSEA & INHALATION OF HARMFUL AMOUNTS OF
MATERIAL. CHRONIC:ALTHOUGH THIS MATERIAL IS NOT A SKIN IRR ITANT, SUBMERSION
BY WORKERS OF UNPROTECTED SKIN IN HIGHLY CONCENTRATED SOLUTIONS OF THIS
MATERIAL FOR PROLONGED PERIODS OF TIME COULD RESULT IN SKIN DEHYDRATION.
=======================================================
Disclaimer (provided with this information by the compiling agencies): This
information is formulated for use by elements of the Department of Defense.
The United States of America in no manner whatsoever expressly or implied
warrants, states, or intends said information to have any application, use or
viability by or to any person or persons outside the Department of Defense
nor any person or persons contracting with any instrumentality of the United
States of America and disclaims all liability for such use. Any person
utilizing this instruction who is not a military or civilian employee of the
United States of America should seek competent professional advice to verify
and assume responsibility for the suitability of this information to their
particular situation regardless of similarity to a corresponding Department
of Defense or other government situation.
*** END OF RECORD *** |
|
|
ALL PAGES On Chemical Property IN THIS GROUP
| NAME | CAS |
RTV103, RTV SILICONE RUBBER SEALANT
| |
DYNACAST A,960-DFGU
| |
GASKET ELIMINATOR 510 SEALANT, 51031
| 25852-47-5 39382-25-7 13676-54-5 68332-62-7 112945-52-5 80-15-9 81-07-2 114-83-0 101-77-9 |
MIL-L-17331H & AM.2 2190 QUAL.#L-17331-3
| |
D-GREEZE 500 RECYCLABLE
| |
PEEL COAT - TYPE I
| |
DRYDENE SFG GREASE LAND 2
| |
GILSALUME ROOF COATING-FIBRAT, 385
| 8052-42-4 8052-41-3 7429-90-5 8052-41-3 13983-17-0 8052-41-3 |
AQUA POWER, 5024
| |
REVIVE-ALL AEROSOL, 5030
| |
LEM'N LIFT, 0328
| |
Z001 CLEAR FLEXIBLE COATINGS, MOISTURE CURE Z001OR
| 101-68-8 100-41-4 1330-20-7 108-10-1 108-88-3 108-65-6 |
WM WASH
| 64742-88-7 108-88-3 110-80-5 |
D-GREEZE 500 RECYCLABLE
| |
SOLDER ALLOYS WITHOUT LEAD
| 7440-74-6 7440-31-5 7440-22-4 7440-69-9 7440-36-0 7440-50-8 |
FRESH FORCE AEROSOL, 5049
| |
ULTRA BOND EPOXY, PART A RESIN COMPONENT
| |
UNIVERSAL TRACTOR FLUID ULTRA GUARD
| |
ENVIROSEAL DOUBLE 7 FOR BLOCK ACTIVATOR - PART A
| |
ENVIROSEAL DOUBLE 7 FOR BLOCK BASE - PART B
| 112945-52-5 |
NITRITE-NITROGEN STANDARD 1ML = 1MGN (1000 PPM)
| 7758-09-0 67-66-3 7732-18-5 |
DETERGENT, GENERAL PURPOSE (SPRAY-ON, WIPE-OFF)
| 57018-52-7 64-02-8 127087-87-0 |
IMPERIAL POLISHING FILM, 60-0000-2075-5
| 25038-59-9 |
IMPERIAL MICROFINISHING FILM-ALUMINUM OXIDE (SUP DAT)
| 25038-59-9 1344-28-1 67700-42-9 |
FINESSE-IT FINAL FINISH, 051144-77452
| 7732-18-5 8052-41-3 1344-28-1 8042-47-5 56-81-5 110-91-8 |
WELD-ON 2719 PVC PLASTIC PIPE CEMENT
| |
USCALRITE MAXI-DRI
| |
CASITE OIL FORTIFIER C173
| 68649-42-3 |
TISSUE FIXATIVE A, H112, H131
| |
INTERTHANE FINISH BLACK, CCY999
| |
INTERTHANE FINISH WHITE, CCB000
| |
390-222 SSS TRIPLE CARPET CLNR-GAL
| |
390-231 SSS BROWN-AWAY-GAL
| |
DUCT SEAL, 31-601
| |
DUCT SEAL, 31-605
| |
FORM-A-GASKET SILICONE BLUE RTV GASKET MAKER, 6M
| 63148-62-9 112945-52-5 4253-34-3 |
DUREZ 12687 MODIFIED TWO STEP PHENOLIC RESIN
| |
GREENPATCH 421
| |
MORTAR MIX 421
| |
CARBOWAX POLYETHYLENE GLYCOL, 1450
| 25322-68-3 75-07-0 123-91-1 75-21-8 50-00-0 |
CARBOWAX POLYETHYLENE GLYCOL, 1450 FLAKE
| 25322-68-3 75-07-0 123-91-1 75-21-8 50-00-0 |
MICROPURE CDF SEMI-AQUEOUS SOLVENT, 0373
| |
BATTERY, 6V, J TYPE, 43816
| 1313-13-9 7440-66-6 1310-58-3 7439-97-6 |
BLUE SEMI-GLOSS POLY-ZEN ENAMEL, 04300BDA
| 13463-67-7 14807-96-6 100-42-5 100-41-4 1330-20-7 |
KEROSENE (1 FUEL OIL)
| 8008-20-6 |
TRANE CLEANER PRIMER, X55010117-09-7
| 71-55-6 124-38-9 75-65-0 109-87-5 149-57-5 22221-10-9 58823-74-8 |
TRANE SAFETY SOLVENT, X55010117-06-7
| 71-55-6 124-38-9 75-65-0 109-87-5 |
CP-K5
| |
B-503
| |
RUS-KIL - WHITE BASE, 0142010
| |
|
|