ULTRA SCIENTIFIC -- CLP-154, CLP VOLATILES MIXTURE 4 AT 2000 (SUP
=======================================================
Material Safety Data Sheet
=======================================================
MSDS Num: BWDSD
MSDS NAME: CLP-154, CLP VOLATILES MIXTURE 4 AT 2000 (SUPDAT)
Responsible Party
Name: ULTRA SCIENTIFIC
Address: 250 SMITH ST
City: N KINGSTOWN RI 02852
Info Phone: 401-294-9400
Emergency Phone Number: 401-294-9400
Published: Y
=======================================================
Contractor Summary
=======================================================
Name: ULTRA SCIENTIFIC
Address: 250 SMITH STREET
City: NORTH KINGSTOWN RI 02852-5000
Phone: 401-294-9400
=======================================================
Ingredients
=======================================================
Cas: 67-56-1
RTECS #: PC1400000
Name: METHANOL (SARA III). LD50 (ORAL,RAT): 12,900 MG/KG.
% Wt: 98.23
OSHA PEL: 200 PPM, S
ACGIH TLV: 200 PPM;250PPMSTEL,S
EPA Rpt Qty: 5000 LBS
DOT Rpt Qty: 5000 LBS
------------------------------
Cas: 67-64-1
RTECS #: AL3150000
Name: ACETONE (SARA III). LD50 (ORAL,RAT): 9750 MG/KG.
% Wt: 0.253
OSHA PEL: 1000 PPM
ACGIH TLV: 750 PPM;1000PPM STEL
EPA Rpt Qty: 5000 LBS
DOT Rpt Qty: 5000 LBS
------------------------------
Cas: 78-93-3
RTECS #: EL6475000
Name: 2-BUTANONE (SARA III). LD50 (ORAL,RAT): 3400 MG/KG.
% Wt: 0.253
OSHA PEL: 200 PPM
ACGIH TLV: 200 PPM;300 PPM STEL
EPA Rpt Qty: 5000 LBS
DOT Rpt Qty: 5000 LBS
------------------------------
Cas: 75-15-0
RTECS #: FF6650000
Name: CARBON DISULFIDE (SARA III)
% Wt: 0.253
OSHA PEL: 20 PPM
ACGIH TLV: 10 PPM, S
EPA Rpt Qty: 100 LBS
DOT Rpt Qty: 100 LBS
------------------------------
Cas: 591-78-6
RTECS #: MP1400000
Name: 2-HEXANONE. LD50 (ORAL,RAT): 2590 MG/KG.
% Wt: 0.253
OSHA PEL: 100 PPM
ACGIH TLV: 5 PPM, S
------------------------------
Cas: 108-10-1
RTECS #: SA9275000
Name: 2-PENTANONE, 4-METHYL-; (4-METHYL-2-PENTANONE). LD50 (ORAL,RAT): 2080
MG/KG.
% Wt: 0.253
OSHA PEL: 100 PPM
ACGIH TLV: 50 PPM;75 PPM STEL
EPA Rpt Qty: 5000 LBS
DOT Rpt Qty: 5000 LBS
------------------------------
Cas: 100-42-5
RTECS #: WL3675000
Name: STYRENE, MONOMER (SARA III). LD50 (ORAL,RAT): 725 MG/KG.
% Wt: 0.253
OSHA PEL: 100 PPM
ACGIH TLV: 50 PPM;100PPM STEL,S
EPA Rpt Qty: 1000 LBS
DOT Rpt Qty: 1000 LBS
------------------------------
Cas: 95-47-6
RTECS #: ZE2450000
Name: O-XYLENE (SARA III). LD50 (ORAL,RAT): 5000 MG/KG.
% Wt: 0.253
OSHA PEL: 100PPM
ACGIH TLV: 100 PPM;150 PPM STEL
EPA Rpt Qty: 1000 LBS
DOT Rpt Qty: 1000 LBS
=======================================================
Health Hazards Data
=======================================================
LD50 LC50 Mixture: SEE INGREDIENTS.
Route Of Entry Inds - Inhalation: YES
Skin: YES
Ingestion: YES
Carcinogenicity Inds - NTP: NO
IARC: YES
OSHA: NO
Effects of Exposure: TOXIC; IRRITANT. ALL CHEMICALS SHOULD BE CONSIDERED
HAZARDOUS-DIRECT PHYSICAL CONTACT SHOULD BE AVOIDED.
Explanation Of Carcinogenicity: STYRENE: IARC MONOGRAPHS, SUPPLEMENT, VOL 7, PG
345, 1987: GROUP 2B. ANIMAL: NERVOUS SYSTEM.
Signs And Symptions Of Overexposure: SEE HEALTH HAZARDS.
Medical Cond Aggravated By Exposure: NONE SPECIFIED BY MANUFACTURER.
First Aid: EYE: FLUSH WITH COPIOUS AMOUNTS OF WATER FOR AT LEAST 15 MINUTES.
SKIN: FLUSH WITH COPIOUS AMOUNTS OF WATER. INHALATION: REMOVE TO FRESH
AIR-GIVE OXYGEN, IF NECESSARY. CONTACT PHYSICIAN. INGESTION: CA LL MD
IMMEDIATELY (FP N).
=======================================================
Handling and Disposal
=======================================================
Spill Release Procedures: DUE TO SMALL QUANTITY INVOLVED, SPILLS OR LEAKS
SHOULD NOT POSE SIGNIFICANT PROBLEM. LEAKING BOTTLE MAY BE PLACED IN PLASTIC
BAG AND NORMAL DISPOSAL PROCEDURES FOLLOWED. LIQUID SAMPLES MAY BE ABSORBED
ON VERMICULITE OR SAND.
Neutralizing Agent: NONE SPECIFIED BY MANUFACTURER.
Waste Disposal Methods: BURN IN CHEMICAL INCINERATOR EQUIPPED WITH AN
AFTERBURNER AND SCRUBBER. OBSERVE ALL FEDERAL, STATE, AND LOCAL LAWS
CONCERNING DISPOSAL.
Handling And Storage Precautions: KEEP TIGHTLY CLOSED, AND STORE IN COOL, DRY
PLACE. MATERIAL SHOULD ONLY BE USED BY THOSE PERSONS TRAINED IN SAFE HANDLING
OF HAZARDOUS CHEMICALS.
Other Precautions: NONE SPECIFIED BY MANUFACTURER.
=======================================================
Fire and Explosion Hazard Information
=======================================================
Flash Point Text: 51.8F,11.0C(FPN)
Extinguishing Media: CARBON DIOXIDE, DRY CHEMICAL POWDER, OR WATER SPRAY.
Fire Fighting Procedures: WEAR NIOSH/MSHA APPROVED SCBA AND FULL PROTECTIVE
EQUIPMENT (FP N).
Unusual Fire/Explosion Hazard: NONE SPECIFIED BY MANUFACTURER.
=======================================================
Control Measures
=======================================================
Respiratory Protection: WEAR NIOSH/MSHA APPROVED RESPIRATOR APPROPRIATE FOR
EXPOSURE OF CONCERN (FP N).
Ventilation: GENERAL VENTILATION SUFFICIENT TO KEEP AIRBORNE CONCENTRATION
BELOW CURRENT EXPOSURE LIMITS (FP N).
Protective Gloves: IMPERVIOUS GLOVES (FP N).
Eye Protection: CHEMICAL GOGGLES, FACE SHIELD.
Other Protective Equipment: WEAR CHEMICAL RESISTANT CLOTHING SUCH AS LABORATORY
COAT AND/OR RUBBER APRON TO PREVENT CONTACT WITH SKIN AND CLOTHING.
Work Hygienic Practices: NONE SPECIFIED BY MANUFACTURER.
Supplemental Safety and Health: PART NUMBER/TRADE NAME: UG/ML IN METHANOL.
=======================================================
Physical/Chemical Properties
=======================================================
Appearance and Odor: LIQUID.
=======================================================
Reactivity Data
=======================================================
Stability Indicator: YES
Stability Condition To Avoid: NONE SPECIFIED BY MANUFACTURER.
Materials To Avoid: STRONG OXIDIZERS.
Hazardous Decomposition Products: NONE SPECIFIED BY MANUFACTURER.
Hazardous Polymerization Indicator: NO
Conditions To Avoid Polymerization: NOT RELEVANT.
=======================================================
Toxicological Information
=======================================================
=======================================================
Ecological Information
=======================================================
=======================================================
MSDS Transport Information
=======================================================
=======================================================
Regulatory Information
=======================================================
=======================================================
Other Information
=======================================================
=======================================================
HAZCOM Label
=======================================================
MSDS NAME: CLP-154, CLP VOLATILES MIXTURE 4 AT 2000 (SUPDAT)
Company: ULTRA SCIENTIFIC
Street: 250 SMITH STREET
City: NORTH KINGSTOWN RI
Zipcode: 02852-5000
Health Emergency Phone: 401-294-9400
Label Required IND: Y
Date Of Label Review: 12/13/1994
Status Code: C
Label Date: 12/13/1994
Origination Code: G
Chronic Hazard IND: Y
Eye Protection IND: YES
Skin Protection IND: YES
Signal Word: DANGER
Respiratory Protection IND: YES
Health Hazard: Moderate
Contact Hazard: Moderate
Fire Hazard: Severe
Reactivity Hazard: None
Hazard And Precautions: COMBUSTIBLE. TOXIC; IRRITANT. ACUTE: ALL CHEMICALS
SHOULD BE CONSIDERED HAZARDOUS-DIRECT PHYSICAL CONTACT SHOULD BE AVOIDED.
CHRONIC: CANCER HAZARD. CONTAINS STYRENE WHICH IS LISTED AS A BLOOD AND LYM
PH SYSTEM CARCINOGEN (FP N).
=======================================================
Disclaimer (provided with this information by the compiling agencies): This
information is formulated for use by elements of the Department of Defense.
The United States of America in no manner whatsoever expressly or implied
warrants, states, or intends said information to have any application, use or
viability by or to any person or persons outside the Department of Defense
nor any person or persons contracting with any instrumentality of the United
States of America and disclaims all liability for such use. Any person
utilizing this instruction who is not a military or civilian employee of the
United States of America should seek competent professional advice to verify
and assume responsibility for the suitability of this information to their
particular situation regardless of similarity to a corresponding Department
of Defense or other government situation.