MORTON INTERNATIONAL - DYNACHE -- DYNACHEM RESIST TREATMENT PWDR RS-1231
=======================================================
Material Safety Data Sheet
=======================================================
MSDS Num: BWWSC
MSDS NAME: DYNACHEM RESIST TREATMENT PWDR RS-1231
Responsible Party
Name: MORTON INTERNATIONAL - DYNACHEM ELECTRONIC MATLS
Address: 2631 MICHELLE DR
City: TUSTIN CA 92680-5000
Info Phone: 714-730-4200
Emergency Phone Number: 714-730-4200
Proprietary Ind: Y
Review Ind: Y
Published: Y
=======================================================
Preparer Co. when other than Responsible Party Co.
=======================================================
Assigned Ind: Y
Name: MORTON INTERNATIONAL; SPECIALTY CHEM GRP
Address: 333 WEST WACKER
City: CHICAGO IL 60606-1292
=======================================================
Contractor Summary
=======================================================
Name: DYNACHEM ELECTRONIC MATERIALS
Address: 2631 MICHELLE DR
City: TUSTIN CA 92680
Phone: 714-730-4200
Name: MORTON INTERNATIONAL; SPECIALTY CHEM GRP
Address: 333 WEST WACKER
City: CHICAGO IL 60606-1292
Phone: 815-338-1800
=======================================================
Ingredients
=======================================================
Name: *** PROPRIETARY ***
-----------------------------
=======================================================
Health Hazards Data
=======================================================
Route Of Entry Inds - Inhalation: NO
Skin: YES
Ingestion: NO
Carcinogenicity Inds - NTP: NO
IARC: NO
OSHA: NO
Effects of Exposure: EYES: BURNS TO CORNEA & OTHER TISSUES, IRRITATION,
CONJUNCTIVITIS & IRITIS. MILD TO MODERATE IRRITATION. INHALATION: NOSE
& THROAT IRRITATION, RESPIRATORY SYSTEM. MAY CAUSE NON-NODULAR FIBROSIS,
EMPHY SEMA. INGESTION: GI IRRITATION.
Explanation Of Carcinogenicity: NONE
Signs And Symptions Of Overexposure: BURNS, IRRITATION, NAUSEA, VOMITING, GI
UPSET, DIZZINESS, FAINTNESS, DROWSINESS, INCOORDINATION (ATAXIA).
Medical Cond Aggravated By Exposure: RESPIRATORY SYSTEM
First Aid: EYES: IMMEDIATELY FLUSH W/WATER FOR 15 MINS. SKIN: WASH W/SOAP &
WATER. INHALATION: REMOVE TO FRESH AIR. GIVE CPR IF NEEDED. INGESTION: INDUCE
VOMITING BY GIVING EITHER SYRUP OF IPECAC FOLLOWED BY 2 G LASSES OF WATER/BY
STICKING FINGER DOWNTHROAT. DON'T GIVE ANYTHING BY MOUTH IF THE PERSON IS
DROWSY, UNCONSCIOUS/HAS NO GAG REFLEX. OBTAIN MEDICAL ATTENTION IN ALL CASES.
=======================================================
Handling and Disposal
=======================================================
Spill Release Procedures: SHOVEL/VACUUM PRODUCT & PLACE IN CLOSED
CONTAINERS FOR FURTHER HANDLING & DISPOSAL. DON'T FLUSH TO SEWER, STREAM,
OTHER BODIES OF WATER.
Waste Disposal Methods: IF DISCARDED IN ITS ORIGINAL UNUSED FORM, THIS PRODUCT
SHOULD BE MANAGED AT AN AUTHORIZED FACILITY IAW/FEDERAL, STATE & LOCAL
REGULATIONS. RECYCLE/REWORK IF AT ALL FEASIBLE/INCINERATE AT AN AUTHORIZED
FACILITY. (SEE SUPP)
Handling And Storage Precautions: STORE IN A COOL DRY, WELL VENTILATED AREA.
CONTAINER CAN BE HAZARDOUS WHEN EMPTY, IT CAN RETAIN PRODUCT RESIDUES. DON'T
REUSE CONTAINER.
Other Precautions: DON'T REUSE CONTAINER FOR FOOD, CLOTHING/PRODUCT FOR
HUMAN/ANIMAL CONSUMPTION/WHERE SKIN CONTACT MAY OCCUR. AVOID BREATHING DUST.
=======================================================
Fire and Explosion Hazard Information
=======================================================
Extinguishing Media: THIS PRODUCT DOESN'T BURN.
Fire Fighting Procedures: NOT REQUIRED.
Unusual Fire/Explosion Hazard: MAY LIBERATE IRRITATING/TOXIC VAPORS DURING
COMBUSTION/DECOMPOSTION.
=======================================================
Control Measures
=======================================================
Respiratory Protection: WEAR NIOSH/MSHA APPROVED EQUIPMENT. DETERMINE THE
APPROPRIATE TYPE EQUIPMENT FOR SPECIFIC APPLICATION BY CONSULTING THE
RESPIRATOR MANUFACTURER. HIGH AIRBORNE CONCENTRATION MAY USE THE
SCBA/SUPPLIED A IR RESPIRATOR.
Ventilation: GENERAL (DILUTION) VENTILATION, LOCAL EXHAUST VENTILATION IS
RECOMMENDED WHEN VAPORS/MISTS/DUST CAN BE RELEASED.
Protective Gloves: IMPERVIOUS
Eye Protection: CHEMICAL SPLASH GOGGLES.
Other Protective Equipment: EYEWASH FACILITY, PROTECTIVE CLOTHING
Work Hygienic Practices: REMOVE/LAUNDER CONTAMINATED CLOTHING BEFORE REUSE.
WASH THOROUGHLY AFTER HANDLING.
Supplemental Safety and Health: DISPOSAL CONT'D: TREAT AT AN ACCEPTABLE WASTE
TREATMENT FACILITY.
=======================================================
Physical/Chemical Properties
=======================================================
Vapor Pres: <1
Spec Gravity: 1.61
Solubility in Water: MODERATELY SOLUBLE
Appearance and Odor: GREY TO BROWN GRANULES/POWDER W/NO ODOR
=======================================================
Reactivity Data
=======================================================
Stability Indicator: YES
Stability Condition To Avoid: HIGH TEMP, WATER REACTIVE MATERIALS.
Materials To Avoid: STRONG BASES
Hazardous Decomposition Products: OXIDES OF SULFUR, SMOKE, SOOT, TOXIC FUMES,
CO2, CO
Hazardous Polymerization Indicator: NO
=======================================================
Toxicological Information
=======================================================
=======================================================
Ecological Information
=======================================================
=======================================================
MSDS Transport Information
=======================================================
=======================================================
Regulatory Information
=======================================================
=======================================================
Other Information
=======================================================
=======================================================
HAZCOM Label
=======================================================
MSDS NAME: DYNACHEM RESIST TREATMENT PWDR RS-1231
Assigned IND: Y
Company: MORTON INTERNATIONAL; SPECIALTY CHEM GRP
Street: 333 WEST WACKER
City: CHICAGO IL
Zipcode: 60606-1292
Health Emergency Phone: 714-730-4200
Label Required IND: Y
Date Of Label Review: 12/16/1998
Status Code: C
Label Date: 12/16/1998
Origination Code: G
Hazard And Precautions: EYES: BURNS TO CORNEA & OTHER TISSUES, IRRITATION,
CONJUNCTIVITIS & IRITIS. MILD TO MODERATE IRRITATION. INHALATION: NOSE
& THROAT IRRITATION, RESPIRATORY SYSTEM. MAY CAUSE NON-NODULAR FIBROSIS,
EMPHY SEMA. INGESTION: GI IRRITATION.
BURNS, IRRITATION, NAUSEA, VOMITING,
GI UPSET, DIZZINESS, FAINTNESS, DROWSINESS, INCOORDI NATION (ATAXIA).
=======================================================
Disclaimer (provided with this information by the compiling agencies): This
information is formulated for use by elements of the Department of Defense.
The United States of America in no manner whatsoever expressly or implied
warrants, states, or intends said information to have any application, use or
viability by or to any person or persons outside the Department of Defense
nor any person or persons contracting with any instrumentality of the United
States of America and disclaims all liability for such use. Any person
utilizing this instruction who is not a military or civilian employee of the
United States of America should seek competent professional advice to verify
and assume responsibility for the suitability of this information to their
particular situation regardless of similarity to a corresponding Department
of Defense or other government situation.
*** END OF RECORD *** |
|
|