BYK-CHEMIE USA -- DISPBERBYK-110
=======================================================
Material Safety Data Sheet
=======================================================
MSDS Num: BXBFM
MSDS NAME: DISPBERBYK-110
Responsible Party
Name: BYK-CHEMIE USA
Address: 524 S CHERRY ST
City: WALLINGFORD CT 06492
Info Phone: 203-265-2086
Emergency Phone Number: 800-424-9300(CHEMTREC)
Preparer's Name: MEGAN MCCUTCHEON
Proprietary Ind: Y
Published: Y
=======================================================
Contractor Summary
=======================================================
Name: BYK-CHEMIE USA
Address: 524 S CHERRY ST
City: WALLINGFORD CT 06492
Phone: 203-265-2086
=======================================================
Ingredients
=======================================================
Name: *** PROPRIETARY ***
-----------------------------
=======================================================
Health Hazards Data
=======================================================
LD50 LC50 Mixture: SEE INGREDIENTS.
Route Of Entry Inds - Inhalation: YES
Skin: YES
Ingestion: NO
Carcinogenicity Inds - NTP: NO
IARC: NO
OSHA: NO
Effects of Exposure: ACUTE:INHAL:HIGH CONCS OF VAPS MAY BE IRRIT TO RESP TRACT.
MAY CAUSE HDCHS, DIZZ, NAUS & VOMIT. MAY CAUSE CNS DEPRESS(DROWS, LOSS OF
COORD & FATG). EYE/SKIN:RPTD/PRLNG CONT MAY CAUSE IRRIT. INGEST:RPT D
INGEST MAY CAUSE IRRIT OF DIGESTIONALTRACT. CHRONIC:SOLV ABSORPTION BY INHAL
&/OR RPTD SKIN CONT MAY(EFTS OF OVEREXP)
Explanation Of Carcinogenicity: NOT RELEVANT
Signs And Symptions Of Overexposure: HLTH HAZ:CAUSE INJURY TO LIVER, KIDNEY
& RESP SYS. STUDIES SUGGEST MINOR ISOMER OF 1-METHOXY-2-PROPANOL ACETATE
IS TERATOGENIC IN ANIMALS. ALSO EVID OF FETOTOXICITY. REPORTS HAVE ASSOC RPTD
& PRLNG OC CUP EXPOS TO SOLVS W/PERM BRAIN & NERV SYS DMG.
INTENTIONAL MISUSE BY DELIB CONC & INHALING VAPS MAY BE HARMFUL/FATAL.
Medical Cond Aggravated By Exposure: MAY BE AGGRAVATING TO SOME SKIN &
ASTHMA-TYPE CONDITIONS & TO PRE-EXISTING LIVER &/OR KIDNEY DISORDERS.
First Aid: INHAL:REMOVE TO FRESH AIR. ADMINISTER ARTIFICIAL RESPIRATION IF
NECESSARY. EYE:IMMEDIATELY FLUSH W/PLENTY OF WATER FOR AT LEAST 15 MINUTES.
GET MEDICAL AID. SKIN:REMOVE CONTAMINATED CLOTHING. WASH THO ROUGHLY W/SOAP
& WATER. INGEST:DO NOT INDUCE VOMITING. DILUTE W/LARGE AMOUNTS OF
MILK/WATER. GET MEDICAL AID. TREAT SYMPTOMATICALLY. NEVER GIVE ANYTHING BY
MOUTH TO AN UNCONSCIOUS PERSON.
=======================================================
Handling and Disposal
=======================================================
Spill Release Procedures: ELIMINATE ALL SOURCES OF IGNITION. VENTILATE AREA IF
INDOORS. WEAR NIOSH/MSHA APPROVED SCBA & FULL PROTECTIVE CLOTHING. STOP
LEAK. DIKE & CONTAIN SPILL. PUMP INTO SALVAGE TANKS &/OR ABSORB
W/SUITABLE MATL. USE SPARKLESS SHOVELS TO REMOVE MATL.
Neutralizing Agent: NONE SPECIFIED BY MANUFACTURER.
Waste Disposal Methods: DISPOSE OF I/A/W APPLICABLE LOCAL, STATE & FEDERAL
LAWS. EPA HAZARDOUS WASTE NUMBER: D001 (IGNITABLE). INCINERATION RECOMMENDED.
Handling And Storage Precautions: HARMFUL IF ABSORBED THRU SKIN. AVOID SKIN
& EYE CONT. AVOID PRLNG BRTHG OF MISTS, VAPORS OR DUSTS. AVOID HEAT,
FLAME, SOURCES OF IGNITION.
Other Precautions: TAKE PRECAUTIONARY MEASURES AGAINST STATIC DISCHARGE. HANDLE
AS INDUSTRIAL CHEMICAL. KEEP CONTAINER TIGHTLY CLOSED WHEN NOT IN USE.
SEPARATION MAY OCCUR AT TEMPS <41F. WARMING TO 70-80F WILL DISSOLVE
SEPARATED FRACTION. MIX WELL BEFORE USE.
=======================================================
Fire and Explosion Hazard Information
=======================================================
Flash Point Method: SCC
Flash Point Text: 111F,44C
Lower Limits: 1%
Upper Limits: 10.8%
Extinguishing Media: FOAM, CARBON DIOXIDE OR DRY CHEMICAL.
Fire Fighting Procedures: USE NIOSH/MSHA APPROVED SCBA & FULL PROTECTIVE
EQUIPMENT (FP N). WATER SPRAY MAY BE USED TO KEEP FIRE EXPOSED CONTAINERS
COOL.
Unusual Fire/Explosion Hazard: KEEP AWAY FROM HEAT & FLAMES. PREVENT STATIC
DISCHARGE. KEEP AWAY FROM OXIDIZING MATERIALS. WILL NOT EXPLODE UPON
MECHANICAL IMPACT.
=======================================================
Control Measures
=======================================================
Respiratory Protection: UNLESS AIR MONITORING DEMONSTRATES VAPOR, MIST OR DUST
LEVELS ARE BELOW THE TLV WEAR A PROPERLY FITTED NIOSH/MSHA APPROVED
RESPIRATOR DURING EXPOSURE.
Ventilation: LOCAL EXHAUST RECOMMENDED.
Protective Gloves: IMPERVIOUS TYPE GLOVES (NEOPRENE).
Eye Protection: ANSI APPROVED CHEM WORKERS GOGGS (FP N).
Other Protective Equipment: EYE WASH FOUNTAIN & DELUGE SHOWER WHICH MEET ANSI
DESIGN CRITERIA (FP N). CLEAN LONG LEGGED, LONG SLEEVED WORK CLOTHES.
Work Hygienic Practices: USE I/A/W GOOD INDUSTRIAL HYGIENE & SAFETY PRACTICES.
Supplemental Safety and Health: NOTE:USERS OF "L" VERSION SHOULD CONSULT "LR"
VERSION FOR ADDITIONAL INFORMATION (FP N).
=======================================================
Physical/Chemical Properties
=======================================================
B.P. Text: >295F,>146C
Vapor Pres: 4 @ 20C
Vapor Density: >1
Spec Gravity: 1.02 (H*2O=1)
Solubility in Water: INSOLUBLE
Appearance and Odor: YELLOWISH LIQUID; AROMATIC ODOR.
=======================================================
Reactivity Data
=======================================================
Stability Indicator: YES
Stability Condition To Avoid: NONE KNOWN.
Materials To Avoid: NONE KNOWN.
Hazardous Decomposition Products: NONE KNOWN.
Hazardous Polymerization Indicator: NO
Conditions To Avoid Polymerization: NOT RELEVANT
=======================================================
Toxicological Information
=======================================================
=======================================================
Ecological Information
=======================================================
=======================================================
MSDS Transport Information
=======================================================
=======================================================
Regulatory Information
=======================================================
=======================================================
Other Information
=======================================================
=======================================================
HAZCOM Label
=======================================================
MSDS NAME: DISPBERBYK-110
Company: BYK-CHEMIE USA
Street: 524 S CHERRY ST
City: WALLINGFORD CT
Zipcode: 06492
Health Emergency Phone: 800-424-9300(CHEMTREC)
Label Required IND: Y
Date Of Label Review: 03/24/1995
Status Code: C
Label Date: 03/24/1995
Origination Code: G
Chronic Hazard IND: Y
Eye Protection IND: YES
Skin Protection IND: YES
Signal Word: WARNING
Respiratory Protection IND: YES
Health Hazard: Slight
Contact Hazard: Slight
Fire Hazard: Moderate
Reactivity Hazard: None
Hazard And Precautions: COMBUSTIBLE. ACUTE:INHAL:HIGH CONCENTRATIONS OF VAPORS
MAY BE IRRITATING TO RESPIRATORY TRACT. MAY CAUSE HEADACHES, DIZZINESS,
NAUSEA & VOMITING. MAY CAUSE CNS DEPRESSION (DROWSINESS, LOSS OF COORDINA
TION & FATIGUE). EYE/SKIN:REPEATED OR PROLONGED CONTACT MAY CAUSE
IRRITATION. INGEST:REPEATED INGESTION MAY CAUSE IRRITATION OF DIGESTIONAL
TRACT. CHRONIC:SOLVENT ABSORPTION BY INHALATION &/OR REPEATE D SKIN
CONTACT MAY CAUSE INJURY TO LIVER, KIDNEY & RESPIRATORY SYSTEM. PROLONGED
OR REPEATED OVEREXPOSURE TO SOLVENTS MAY CAUSE PERMANENT BRAIN & NERVOUS
SYSTEM DAMAGE.
=======================================================
Disclaimer (provided with this information by the compiling agencies): This
information is formulated for use by elements of the Department of Defense.
The United States of America in no manner whatsoever expressly or implied
warrants, states, or intends said information to have any application, use or
viability by or to any person or persons outside the Department of Defense
nor any person or persons contracting with any instrumentality of the United
States of America and disclaims all liability for such use. Any person
utilizing this instruction who is not a military or civilian employee of the
United States of America should seek competent professional advice to verify
and assume responsibility for the suitability of this information to their
particular situation regardless of similarity to a corresponding Department
of Defense or other government situation.