Effects of Overexposure:ANESTHETIC. IRRITATION OF THE RESPIRATORY
TRACT, HEADACHE/DIZZINESS/STAGGERING GAIT/CONFUSION/COMA
======================= First Aid Measures =======================
First Aid:INHALATION: REMOVE FROM EXPOSURE. RESTORE BREATHING. KEEP
WARM/QUIET. NOTIFY PHYS. EYES: FLUSH W/WATER FOR AT LEAST 15
MINUTES. TAKE TO PHYS FOR DEFINITIVE MEDICAL TREATMENT. SKIN:
REMOVE W/SOAP & WAT ER. REMOVE CONTAMINATED CLOTHING.
===================== Fire Fighting Measures =====================
Flash Point:28F
Lower Limits:1.0%
Extinguishing Media:CO2, DRY CHEMICAL
Fire Fighting Procedures:USE FULL PROTECTIVE EQUIPMENT, SCBA TO PROTECT
FIREFIGHTERS.
Unusual Fire/Explosion Hazard:CLOSED CONTAINERS MAY EXPLODE WHEN
EXPOSED TO EXTREME HEAT. KEEP AWAY FROM SOURCES OF IGNITION.
Spill Release Procedures:REMOVE ALL SOURCES OF IGNITION (FLAMES, HOT
SURFACES, & ELECTRICAL, STATIC, OR FRICTNAL SPARKS). AVOID
BREATHING VAPORS. VENTILATE AREA. REMOVE WITH INERT AORBENT &
NON-SPARKING TOOLS.
====================== Handling and Storage ======================
Handling and Storage Precautions:DON'T STORE >120F. STORE LARGE
QUANTITIES IN BUILDINGS DESIGNED FOR STORAGE OF NFPA CLASS II
FMMABLE LIQUIDS. DON'T TAKE INTERNALLY.
Other Precautions:CONTAINERS SHOULD BE GROUNDED WHEN POURING. DON'T
FLAME CUT, BRAZE, OR WELD W/NIOSH APPROVED RESPIRATOR OR
APPROPRIATE VENTITION. KEEP CONTAINER CLOSED WHEN NOT IN USE.
Boiling Pt:B.P. Text:174-340F
Vapor Density:>AIR
Evaporation Rate & Reference:SLOWER THAN ETHER
Percent Volatiles by Volume:81.8
================= Stability and Reactivity Data =================
Stability Indicator/Materials to Avoid:YES
STRONG OXIDIZERS
Stability Condition to Avoid:KEEP AWAY FROM HOT SURFACES SOURCES OF
IGNITION.
Hazardous Decomposition Products:OXIDES OF CARBON
Conditions to Avoid Polymerization:KEEP AWAY FROM HOT SURFACES, SOURCES
OF IGNITION.
Waste Disposal Methods:DISPOSE OF IN ACCORDANCE WITH LOCAL, STATE &
FEDERAL REGULATIONS. DO NOT INCINERATE CLOSED CONTAINERS.
Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.