ing 06: periods of time. post "no smoking" or "open flames" msds toxicity property">
supp data: protect cntnrs from physical dmg. store in cool, ing 02: from heavily trafficked areas & emer exits. do not ing 03: cyl should be stored upright & firmly secured to ing 04: should be stored upright & firmly secured to pvnt ing 05: should be segregated. use "first in-first out" ing 06: periods of time. post "no smoking" or "open flames" msds toxicity property">
MSDS  
:
PROPANE
CAS  
:
74-98-6
NAME  
:
propane supp data: protect cntnrs from physical dmg. store in cool, ing 02: from heavily trafficked areas & emer exits. do not ing 03: cyl should be stored upright & firmly secured to ing 04: should be stored upright & firmly secured to pvnt ing 05: should be segregated. use "first in-first out" ing 06: periods of time. post "no smoking" or "open flames"
LD50 LC50 Mixture:NONE SPECIFIED BY MANUFACTURER.
Routes of Entry: Inhalation:YES Skin:NO Ingestion:NO
Reports of Carcinogenicity:NTP:NO IARC:NO OSHA:NO
Health Hazards Acute and Chronic:INHAL: MODERATE CONCENTRATIONS SO AS
TO EXCLUDE AN ADEQUATE SUPPLY OF OXYGEN TO THE LUNGS CAUSES
DIZZINESS, DROWSINESS AND EVENTUAL UNCONSCIOUSNESS. IT IS ALSO A
NARCOTIC WHICH ACTS AS A DEPRESSANT ON THE CENTRAL NERVOUS SYSTEM.
CONTACT WITH RAPIDLY EVAPORATING LIQUID COULD CAUSE FROSTBITE OR
CRYOGENIC BURNS.
Explanation of Carcinogenicity:NOT RELEVANT
Effects of Overexposure:SEE HEALTH HAZARDS
Medical Cond Aggravated by Exposure:NONE SPECIFIED BY MANUFACTURER.
======================= First Aid Measures =======================
First Aid:INHAL: QUICK REMOVAL OF CONSCIOUS PERSONS TO FRESH AIR IS
MOST IMPORTANT. MOVE UNCONSCIOUS PERSONS TO AN UNCONTAM AREA, GIVE
MOUTH-TO-MOUTH RESUS & SUPP O*2. FURTHER TREATMENT SHOULD BE
SYMPTOMATIC & SUPPORTIVE. SKIN: REMOVE CONTAM CLTHG &FLUSH
AFFECTED AREAS W/LUKEWARM WATER. DO NOT USE HOT WATER. GET MD IMMED
IF THE CRYOGENIC BURN HAS RESULTED IN BLISTERING OF SKIN SURF OR
DEEP TISS FREEZING.
===================== Fire Fighting Measures =====================
Flash Point Method:CC
Flash Point:-156F,-104C
Lower Limits:2.2
Upper Limits:9.5
Extinguishing Media:WATER, CARBON DIOXIDE, DRY CHEMICAL
Fire Fighting Procedures:WEAR NIOSH/MSHA APPROVED SCBA AND FULL
PROTECTIVE EQUIPMENT . IF POSSIBLE, STOP THE FLOW OF PROPANE. USE
WATER SPRAY TO COOL SURROUNDING CONTAINERS.
Unusual Fire/Explosion Hazard:PROPANE IS >AIR & MAY TVL CONSIDER DIST
TO IGNIT SOURCE. SHOULD FLAME BE EXTING & FLOW OF GAS CON'T,
INCREASE VENT TO PVNT FLAMM MIX FORM IN LOW AREAS/POCKETS.
Spill Release Procedures:EVACUATE PERS FROM AREA. USE APPROP PROT
EQUIP. IF LEAK IS IN USER'S EQUIP, BE CERTAIN TO PURGE PIPING WITH
AN INERT GAS PRIOR TO ATTEMPTING REPAIRS. IF LEAK IS IN CNTNR, OR
CNTNR VALVE, CONTACT CHEMT REC FOR EMER ASSIST OR CLOSEST MFR'S
LOCATION.
Neutralizing Agent:NONE SPECIFIED BY MANUFACTURER.
====================== Handling and Storage ======================
Handling and Storage Precautions:USE ONLY IN WELL VENT AREAS. VALVE
PROT CAPS MUST REMAIN IN PLACE UNLESS CNTNR IS SECURED W/VALVE
OUTLET PIPED TO USE POINT. DO NOT (SEE SUPP DATA)
Other Precautions:EARTH-GROUND & BOND ALL LINES & EQUIPMENT ASSOCIATED
WITH PROPANE SYSTEM. ELECTRICAL EQUIPMENT SHOULD BE NON-SPARKING OR
EXPLOSION PROOF. COMPRESSED GAS CYLINDER SHOULD NOT BE REFILLED
EXCEPT BY QUALI FIED PRODUCERS OF COMPRESSED GAS.
Respiratory Protection:NIOSH/MSHA APPROVED POSITIVE PRESSURE AIR LINE
RESPIRATOR OR NIOSH/MSHA APPROVED SCBA SHOULD BE AVAILABLE FOR
EMERGENCY USE.
Ventilation:HOOD WITH FORCED VENTILATION. LOCAL EXHAUST TO PREVENT
ACCUMULATION ABOVE THE LEL.
Protective Gloves:PLASTIC OR RUBBER
Eye Protection:CHEMICAL WORKERS GOGGLES
Other Protective Equipment:SAFETY SHOES, SAFETY SHOWER
Work Hygienic Practices:WASH HANDS THOROUGHLY AFTER USE AND BEFORE
EATING, DRINKING, SMOKING OR USING SANITARY FACILITIES .
Supplemental Safety and Health
HNDLG/STOR PREC: DRAG, SLIDE, ROLL CYL. USE SUITABLE HAND TRUCK FOR
MOVEMENT. USE PRESS REDUCING REGULATOR WHEN CONNECTING CYL TO LOWER
PRESS (<250 PSIG) PIPING/SYSTEMS. DO NOT HEAT CYL BY ANY MEANS T O
INCREASE DISCH RATE OF PROD FROM CYL.USE CHECK VALVE/TRAP IN DISCH
LINE TP PVNT HAZ BACK FLOW IN CYL. (SEE INGRED 02)
HCC:G2
Boiling Pt:B.P. Text:-44F,-42C
Melt/Freeze Pt:M.P/F.P Text:-306F,-188C
Vapor Pres:127 PSIA
Vapor Density:1.55
Spec Gravity:1.56
Solubility in Water:NEGLIGIBLE
Appearance and Odor:COLORLESS, ODORLESS GAS
================= Stability and Reactivity Data =================
Stability Indicator/Materials to Avoid:YES
OXIDIZERS.
Stability Condition to Avoid:NONE SPECIFIED BY MANUFACTURER.
Hazardous Decomposition Products:NONE
Waste Disposal Methods:DO NOT ATTEMPT TO DISPOSE OF WASTE OR UNUSED
QTYS. RETURN IN THE SHIPPING CONTAINER PROPERLY LABELED, WITH ANY
VALVE OUTLET PLUGS OR CAPS SECURED & VALVE PROTECTION CAP IN PLACE
TO MFR FOR PROPER DISP OSAL.
Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.