MSDS  : 356 CORROSION INHIBITOR
CAS  : 108-91-8
110-91-8
NAME  : cyclohexylamine
morpholine
waste disp meth: local, state and federal regulations.
resp prot: pressure-demand, self-contained breathing
supp data: respiratory depression and convulsions may be
spill proc: truck for disp. keep spill away from heat,
ing 6: from exposure if airborne concentration exceeds tlv.
===================== Product Identification =====================

MSDS NAME:356 CORROSION INHIBITOR
NIIN:00N024011
MSDS Number: BLYXB
=== Responsible Party ===
Company:NALCO CHEMICAL CO
Address:ONE NALCO CENTER
City:NAPERVILLE
State:IL
ZIP:60566-1024
Country:US
Info Phone Num:708-305-1000
Emergency Phone Num:708-920-1510
Preparer's Name:JOHN J. KASPER
CAGE:89524
=== Contractor Identification ===
Company:ONDEO NALCO COMPANY
Address:ONDEO NALCO CENTER
Box:City:NAPERVILLE
State:IL
ZIP:60563-1198
Country:US
Phone:(630) 305-1000
CAGE:89524

============= Composition/Information on Ingredients =============

Name:CYCLOHEXYLAMINE
CAS:108-91-8
RTECS #:GX0700000
Fraction by Wt: 20-40%
OSHA PEL:10 PPM
ACGIH TLV:10 PPM

Name:MORPHOLINE
CAS:110-91-8
RTECS #:QD6475000
Fraction by Wt: 1-10%
OSHA PEL:20 PPM,30 PPM STEL,S
ACGIH TLV:20 PPM,30 PPM STEL,S

Name:WASTE DISP METH: LOCAL, STATE AND FEDERAL REGULATIONS.
RTECS #:9999999ZZ

Name:RESP PROT: PRESSURE-DEMAND, SELF-CONTAINED BREATHING
APPARATUS IS RECOMMENDED.
RTECS #:9999999ZZ

Name:SUPP DATA: RESPIRATORY DEPRESSION AND CONVULSIONS MAY BE
NEEDED.
RTECS #:9999999ZZ

Name:SPILL PROC: TRUCK FOR DISP. KEEP SPILL AWAY FROM HEAT,
SPARKS, FLAMES/WELDING OPER. VENT AREA & EVAC EMPLOYEES (ING 7)
RTECS #:9999999ZZ

Name:ING 6: FROM EXPOSURE IF AIRBORNE CONCENTRATION EXCEEDS TLV.
RTECS #:9999999ZZ

===================== Hazards Identification =====================

LD50 LC50 Mixture:LD50: (ORAL,RAT) 779 MG/KG.
Routes of Entry: Inhalation:YES Skin:YES Ingestion:YES
Reports of Carcinogenicity:NTP:NO IARC:NO OSHA:NO
Health Hazards Acute and Chronic:EYE: CORR TO EYES W/POSS PERM DMG
DEPENDING ON LENGTH OF EXPOS & ON FIRST AID ACTION GIVEN. SKIN:
CORR TO SKIN, POSS RSLTG IN 3RD DEGREE BURNS DEPENDING ON LENGTH OF
EXPOS & ON FIRST AID ACTION GIVEN. CAN CAUSE ALLERGIC CONT DERM IN
SUSCEPTIBLE INDIV. INGEST: CAN CAUSE KIDNEY DMG.CAN BE HARMFUL.
INHAL:(EFTS OF OVEREXP)
Explanation of Carcinogenicity:NOT RELEVANT.
Effects of Overexposure:HLTH HAZ: CAN BE CORR TO MUCOUS MEMBRANES AND
LUNGS. CAN CAUSE AN ALLERGIC REACTION IN SUSCEPTIBLE INDIVIDUALS.
SEE ORIGINAL MSDS FOR ACUTE ANIMAL TOXICITY STUDIES.
Medical Cond Aggravated by Exposure:CYCLOHEXYLAMINE HAS BEEN SHOWN TO
CAUSE AN ALLERGIC REACTION IN EXPERIMENTAL ANIMALS.

======================= First Aid Measures =======================

First Aid:EYE: IMMED FLUSH FOR AT LEAST 15 MIN WHILE HOLDING EYELIDS
OPEN. CALL PHYS AT ONCE. SKIN: IMMED FLUSH W/H*2O FOR AT LEAST 15
MIN. FOR LRG SPLASH, FLOOD BODY UNDER SHOWER. CALL PHYS AT ONCE.
INGEST: DO NOT INDUCE VOMIT. GIVE H*2O. CALL PHYSAT ONCE. INHAL:
REMOVE TO FRESH AIR. TREAT SYMP. CALL PHYS AT ONCE. IF UNCON,
HAVING TROUBLE BRTHG/IN CONVULSIONS, DO NOT INDUCE VOMIT/GIVE H*2O.
NOTE (SUP DAT)

===================== Fire Fighting Measures =====================

Flash Point Method:PMCC
Flash Point:135F,57C
Extinguishing Media:BASED ON NFPA GUIDE, DRY CHEMICAL, ALCOHOL FOAM,
CARBON DIOXIDE OR OTHER EXTINGUISHING AGENT SUITABLE FOR CLASS B
FIRES.
Fire Fighting Procedures:USE NIOSH/MSHA APPRVD SCBA & FULL PROT EQUIP .
USE H*2O TO COOL CNTNRS EXPOS TO FIRE. FOR LARGE FIRES, USE H*2O
SPRAY/FOG, THORO DRENCHING BURNING MATL.
Unusual Fire/Explosion Hazard:MAY EVOLVE NO*X UNDER FIRE CNDTNS. CNTNRS
EXPOS IN FIRE SHD BE COOLED W/H*2O TO PVNT VAP PRESS BUILDUP
LEADING TO RUPTURE. CONTACT W/REACTIVE METALS (SUP DAT)

================== Accidental Release Measures ==================

Spill Release Procedures:SMALL LIQ SPILLS: CONT W/ABSORB MATL, SUCH AS
CLAY, SOIL/ANY COMMERCIALLY AVAIL ABSORB. SHOVEL RECLAIMED LIQ &
ABSORB INTO RECOVERY/SALVAGE DRUMS FOR DISP. LRG SPILLS: DIKE TO
PVNT FURTHER MOVEMENT & RECLAIM INTO RECOVERY/SALVAGE DRUMS/TANK
(ING 6)
Neutralizing Agent:NONE SPECIFIED BY MANUFACTURER.

====================== Handling and Storage ======================

Handling and Storage Precautions:DANGER: CORR TO TISS. DO NOT GET IN
EYES, ON SKIN/ON CLTHG. AVOID BRTHG VAPS. USE W/ADEQ VENT. DO NOT
TAKE INTERNALLY. KEEP AWAY FROM HEAT/OPEN FLAME.
Other Precautions:KEEP CONTAINER CLOSED WHEN NOT IN USE. EMPTY
CONTAINERS MAY CONTAIN RESIDUAL PRODUCT. DO NOT REUSE CONTAINER
UNLESS PROPERLY RECONDITIONED.

============= Exposure Controls/Personal Protection =============

Respiratory Protection:IF IT IS POSS TO GEN SIGNIFICANT LEVS OF
VAPS/MISTS, A NIOSH/MSHA APPROVED/EQUIV HALF-FACE MASK W/GREEN
CARTRIDGE RESP IS RECOM. FOR LRG SPILLS, ENTRY INTO LRG TANKS,
VESSELS/ENCLOSED SMALL SPACES W/I NADEQ VENT, A NIOSH/MSHA APPRVD
(ING 4)
Ventilation:GEN VENT IS RECOMMENDED. ADDITIONALLY, LOCAL EXHAUST
VENTILATION IS RECOM WHERE VAPS, MISTS OR AEROSOLS MAY BE RELSD.
Protective Gloves:IMPERMEABLE GLOVES.
Eye Protection:CHEM WORK GOG & FULL LGTH FACESHLD
Other Protective Equipment:RUBBER BOOTS, APRON, A FULL SLICKER SUIT IS
RECOMMENDED IF GROSS EXPOSURE IS POSSIBLE. EYE WASH FOUNTAIN & SFTY
SHOWER.
Work Hygienic Practices:IF CLOTHING IS CONTAMINATED, REMOVE CLTHG AND
THOROUGHLY WASH AFFECTED AREA. LAUNDER CONTAMINATED CLTHG BEFORE
REUSE.
Supplemental Safety and Health
EXPLO HAZ: (E.G. ALUMINUM) MAY RSLT IN GENERATION OF FLAM HYDROGEN GAS.
FIRST AID PROC: TO PHYS: NO SPECIFIC ANTIDOTE IS KNOWN. BASED ON
INDIV RXNS OF PATIENT, PHYS JUDGMENT SHD BE USED TO CNTRL SYMP &
CLINICAL CNDTN. PROBABLE MUC DMG MAY CONTRAINDICATE USE OF GASTRIC
LAVAGE. MEASURES AGAINST CIRCULATORY SHOCK, (ING 5)

================== Physical/Chemical Properties ==================

HCC:F4
Spec Gravity:0.99 @ 60F
pH:12
Solubility in Water:COMPLETELY
Appearance and Odor:LIGHT GREEN LIQUID, AMINE ODOR.

================= Stability and Reactivity Data =================

Stability Indicator/Materials to Avoid:YES
SEE MSDS FOR MATERIALS TO AVOID.
Stability Condition to Avoid:NONE SPECIFIED BY MANUFACTURER.
Hazardous Decomposition Products:IN EVENT OF COMBUSTION CO, CO*2, NO*X
MAY BE FORMED.

==================== Disposal Considerations ====================

Waste Disposal Methods:IF PROD BECOMES WASTE, IT MEETS CRITERIA OF HAZ
WASTE AS DEFINED UNDER RCRA 40 CFR 261. HAZ WASTE D001. AS HAZ LIQ
WASTE, IT MUST BE SOLIDIFIED BEFORE DISP IN LANDFILL (HAZ WASTE
TREATMENT, STORAGE & DISP FACILITY). CAN BE INCINERATED I/A/W (ING
3)

Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.

*** END OF RECORD ***
Search More   
ALL PAGES On Chemical Property IN THIS GROUP
NAMECAS
2301 ANTIFOAM
FIREPREP 1000 FUEL CONDITIONER 61791-39-7
68476-30-2
64742-94-5
WINTER POW-R PLUS 64742-94-5
9002-93-1
91-20-3
SOLUTION S0636 PA-2
SOLUTION S0280 H-7 CALCIUM HAR
SOLUTION S0277 H-3 TOTAL HARDN
SOLUTION S0193 EX-3 7758-01-2
356 CORROSION INHIBITOR 108-91-8
110-91-8
SOLUTION S0163 R0891 MOLYBDEN 64-17-5
67-56-1
MONOCHLOROTRIFLUOROMETHANE
SHEETROCK-TAPING JOINT COMPOUND 1317-65-3
12001-26-2
14807-96-6
1332-58-7
9002-89-5
9003-20-7
9004-65-3
9005-25-8
9004-62-0
137-30-4
ETHYL ALCOHOL, ETHANOL 64-17-5
SODIUM ACETATE ANHYDROUS, S-210 126-96-5
BRAZED TUNGSTEN CARBIDE TOOLS 12070-12-1
7440-48-4
12070-06-3
12012-35-0
7440-47-3
7440-22-4
7440-50-8
7440-66-6
7440-43-9
7440-02-0
EPOXY COATING, MIL-C-22750D #36231 PTB 25036-25-3
107-98-2
13463-67-7
21645-51-2
112945-52-5
14807-96-6
123-86-4
111-15-9
108-88-3
1330-20-7
78-93-3
EPOXY CURING AGENT MIL-L-22750D #30,000 PTA 67-63-0
123-86-4
111-15-9
78-93-3
108-88-3
1330-20-7
TT-E-508C ALKYD SG TINT BASE, B508TB WHITE 64741-41-9
14808-60-7
HYDROGEN 1333-74-0
SOAP, SCRUBBING, ALKALINE (POWDER) 61789-66-0
497-19-8
TT-E-508C ALKYD SG TINT BASE, B508TB, WHITE 64741-41-9
14808-60-7
TT-E-508C ALKYD SG TINT BASE, B508TB WHITE 64741-41-9
14808-60-7
FA-1076 78-93-3
109-99-9
108-10-1
9003-18-3
CITRIC ACID, A1043-A-940 77-92-9
HI-FI DEVELOPER PART A
MIL-C-22750D #34079 PTB 25036-25-3
107-98-2
20344-49-4
14807-96-6
1330-20-7
123-86-4
111-15-9
108-88-3
78-93-3
MIL-L-22750D #30,000 PTA 67-63-0
123-86-4
111-15-9
78-93-3
108-88-3
1330-20-7
DTE OIL HEAVY MEDIUM 64742-54-7
64742-54-7
PAINT,OIL,TINT BASE 13463-67-7
14808-60-7
8001-26-1
66070-60-8
8052-41-3
ENAMEL, NONFLAMING (DRY) CHLORINATED ALKYD 7727-43-7
13463-67-7
1592-23-0
ENAMEL, NONFLAMING (DRY) CHLORINATED ALKYD, 7727-43-7
13463-67-7
1592-23-0
TT-E-508C ALKYDSG TINT BASE, B508TB YELLOW 64741-41-9
14808-60-7
TT-E-508C ALKYD SG TINT BASE, B508TB RED 21 64741-41-9
14808-60-7
TT-E-508C ALKYD SG TINT BASE B508TB IVORY 2 64741-41-9
14808-60-7
TT-E-508C ALKYD SG TINT BASE, B508TB YELLOW 64741-41-9
14808-60-7
TT-E-508C ALKYD SG B508 20219 BROWN 20219 64741-41-9
14808-60-7
39-80055-044, PART A 106-89-8
2426-08-6
PST-690 PRIMER
DTE OIL HEAVY MEDIUM 64742-54-7
ACTIVATOR A 111-40-0
TT-E-508C ALKYD SG TINT BASE, B508TB WHITE 64741-41-9
14808-60-7
SODIUM ACETATE ANHYDROUS, S-210 126-96-5
SHEETROCK TOPPING JOINT COMPOUND 1317-65-3
12001-26-2
14807-96-6
1332-58-7
9002-89-5
9003-20-7
9004-65-3
9005-25-8
9004-62-0
137-30-4
THYODENE, T-138
SUPER TRUMP
EPOXY COATING MIL-C-2275OD #24084 PTB 25036-25-3
107-98-2
20344-49-4
1333-86-4
12656-85-8
7439-92-1
7440-47-3
123-86-4
141-78-6
108-88-3
78-93-3
14807-96-6
CURING AGENT, MIL-C-22750D, #20,000 PTA 67-63-0
123-86-4
141-78-6
108-88-3
3M EC-847 67-64-1
9003-18-3
9003-35-4
8050-31-5
69-72-7
1314-13-2
37338-62-8
BIO-TERGE AS-40,604287
FO621 141-43-5
102-71-6
EPOXY COATING MIL-C-22750D #35044 PTB 25036-25-3
107-98-2
13463-67-7
1333-86-4
14807-96-6
123-86-4
111-15-9
108-88-3
1330-20-7
78-93-3

Free MSDS Search ( Providing 250,000+ Material Properties )
Chemcas.com| Ads link:todaystock.net