===================== Product Identification =====================
MSDS NAME:R-373 RUBBER INSUL ADHESIVE, 373
NIIN:01-017-1507
MSDS Number: BMBWS
=== Responsible Party ===
Company:RUBATEX CORP
Address:805 MONROE ST
City:BEDFORD
State:VA
ZIP:24523
Country:US
Info Phone Num:703-586-2611
Emergency Phone Num:703-586-2611
Preparer's Name:W.F. CREASY
CAGE:IO124
=== Contractor Identification ===
Company:RUBATEX CORP
Address:805 MONROE ST
Box:340
City:BEDFORD
State:VA
ZIP:24523
Country:US
Phone:800-378-4091
CAGE:IO124
Company:RUBATEX CORP SUB OF GREAT AMERICAN INDUSTRIES INC
Address:605 ADAMS ST
Box:340
City:BEDFORD
State:VA
ZIP:24523
Country:US
CAGE:82942
============= Composition/Information on Ingredients =============
Name:TOLUENE (SARA III). VP:22
CAS:108-88-3
RTECS #:XS5250000
Fraction by Wt: 16%
OSHA PEL:200 PPM/150 STEL
ACGIH TLV:50 PPM; 9293
EPA Rpt Qty:1000 LBS
DOT Rpt Qty:1000 LBS
Name:HEXANE; (N-HEXANE). VP:140
CAS:110-54-3
RTECS #:MN9275000
Fraction by Wt: 28%
OSHA PEL:500 PPM
ACGIH TLV:50 PPM; 9293
EPA Rpt Qty:1 LB
DOT Rpt Qty:1 LB
Name:ACETONE (SARA III). VP:186
CAS:67-64-1
RTECS #:AL3150000
Fraction by Wt: 36%
OSHA PEL:1000PPM
ACGIH TLV:750PPM/1000STEL;9293
EPA Rpt Qty:5000 LBS
DOT Rpt Qty:5000 LBS
===================== Hazards Identification =====================
LD50 LC50 Mixture:NONE SPECIFIED BY MANUFACTURER.
Routes of Entry: Inhalation:YES Skin:YES Ingestion:YES
Reports of Carcinogenicity:NTP:NO IARC:NO OSHA:NO
Health Hazards Acute and Chronic:NOTE:TOLUENE (108-88-3) APPEARS ON
NAVY LIST OF OCCUP CHEMCIAL REPRO HAZARDS. CONSULT WITH APPROP
HEALTH PROFS CONCERNING LATEST HAZ LIST INFO & SAFE HNDLG & EXPOS
RECOMS . INHAL:DIZZINESS, BREA THING DIFFICULTY, HEADACHE & LOSS OF
COORDINATION. EYE:SEVERE IRRITATION, TEARING, REDNESS & BLURRED
(EFTS OF OVEREXPOS)
Explanation of Carcinogenicity:NOT RELEVANT
Effects of Overexposure:HEALTH HAZARDS: VISION. SKIN:CAN DRY & DEFAT
SKIN CAUSING CRACKS, IRRITATION & DERMATITIS. INGEST:CAN CAUSE
GASTROINTESTINAL IRRITATION, VOMITING, NAUSEA & DIARRHEA.
Medical Cond Aggravated by Exposure:ANESTHESIA, RESPIRATORY TRACT
IRRITATION, DERMATITIS, NAUSEA, VOMITING.
======================= First Aid Measures =======================
First Aid:INHAL: MOVE PERSON TO FRESH AIR. IF BRTHG STOPS, APPLY ARTF
RESP & SEEK IMMED MED ATTN. EYE: FLUSH W/LRG QTYS OF H*2O FOR AT
LEAST 15 MINUTES. SKIN: WASH THOROUGHLY WITH SOAP AND WATER AND SEE
A DOCTO R. INGEST: DO NOT INDUCE VOMITING, CAN CAUSE CHEMICAL
PNEUMONITIS EDEMA. CONTACT A PHYSICIAN IMMEDIATELY.
===================== Fire Fighting Measures =====================
Flash Point Method:CC
Flash Point:-14F,-26C
Lower Limits:1.0%
Extinguishing Media:FOAM, CO*2, DRY CHEMICAL.
Fire Fighting Procedures:USE NIOSH/MSHA APPROVED SCBA AND FULL
PROTECTIVE EQUIPMENT . WATER SHOULD NOT BE USED EXCEPT AS FOG TO
KEEP NEARBY CONTRS COOL.
Unusual Fire/Explosion Hazard:HNDL AS FLAM LIQ. VAPS FROM AN EXPLOSIVE
MIXTURE IN AIR BETWEEN THE UPPER AND LOWER EXPLOSIVE LIMITS WHICH
CAN BE IGNITED BY MANY SOURCES SUCH (SEE SUPP DATA)
================== Accidental Release Measures ==================
Spill Release Procedures:ELIMINATE IGINITION SOURCES, PROVIDE GOOD
VENTILATION, DIKE SPILL AREA AND USE ABSORBANT MATERIAL TO CLEANUP.
COLLECT ABSORBANT/SPILLED LIQUID MIXTURE AND PLACE INTO METAL
CONTAINERS.
Neutralizing Agent:NONE SPECIFIED BY MANUFACTURER.
====================== Handling and Storage ======================
Handling and Storage Precautions:USE NON-SPARKING UTENSILS WHEN HNDLG
MATL. AVOID HOT METAL SURFS, USE IN COOL, WELL-VENT AREAS. KEEP
CONTRS CLSD WHEN NOT IN USE.
Other Precautions:KEEP AWAY FROM EXCESSIVE HEAT AND OPEN FLAMES.
SMOKING IN AREAS WHERE MATL IS USED SHOULD BE STRICTLY PROHIBITED.
TOOLS USED W/MATL SHOULD BE MADE OF ALUMINUM, BRASS, OR COPPER.
PLASTIC UTENSILS SHOUL D NOT BE USED.
============= Exposure Controls/Personal Protection =============
Respiratory Protection:WHEN SPRAYING THIS ADHESIVE USE A NIOSH/MSHA
APPRVD CARTRIDGE RESP/GAS MASK SUITABLE TO KEEP AIRBORN MISTS &
CONC BELOW TWA/TLV. WHEN USING IN POORLY VENT & CONFINED SPACES,
USE A NIOSH/MSHA APPRVD(SE E SUPP DATA)
Ventilation:GEN MECH VENT/LOCAL EXHAUST SHOULD BE SUITABLE TO KEEP VAP
CONC BELOW TLV. VENT EQUIP MUST BE EXPLOSION PROOF.
Protective Gloves:IMPERMEABLE GLOVES.
Eye Protection:CHEM WORK GOG & FULL LGTH FCSHLD .
Other Protective Equipment:USE IMPERMEABLE APRONS & PROT CLTHG WHENEVER
POS TO PVNT SKIN CONTACT. USE OF HEAD CAPS WHENEVER POS IS STRONGLY
RECOM.
Work Hygienic Practices:EYE WASHES AND SAFETY SHOWERS IN WORKPLACE IS
RECOMMENDED.
Supplemental Safety and Health
EXPLO HAZ:AS PILOT LIGHTS, OPEN FLAMES, ELECTRICAL MOTORS & SWITCHES.
RESP PROT:FRESH-AIR SUPPLYING RESP OR SCBA.
================== Physical/Chemical Properties ==================
Boiling Pt:B.P. Text:>132F,>56C
Vapor Pres:SEE INGRED
Vapor Density:HVR/AIR
Spec Gravity:0.8
Evaporation Rate & Reference:SLOWER THAN ETHER
Solubility in Water:NO
Appearance and Odor:BLUE, OFFENSIVE ODOR.
================= Stability and Reactivity Data =================
Stability Indicator/Materials to Avoid:YES
ALKALINE MATERIALS, STRONG ACIDS AND OXIDIZING MATERIALS.
Stability Condition to Avoid:EXCESSIVE HEAT, POOR VENTILATION,
CORROSIVE ATMOSPHERES, EXCESSIVE AGING.
Hazardous Decomposition Products:CARBON MONOXIDE, CARBON DIOXIDE,
OXIDES OF NITROGEN, AND POSSIBLE ACROLEIN.
==================== Disposal Considerations ====================
Waste Disposal Methods:CONSULT LOCAL, STATE AND FEDERAL HAZARDOUS WASTE
REGULATIONS BEFORE DISPOSING INTO APPROVED HAZARDOUS WASTE
LANDFILLS. OBEY RELEVANT LAWS.
Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.
*** END OF RECORD *** |
|
|