===================== Product Identification =====================
MSDS NAME:GEAR OIL SAE 90, CPS250402
NIIN:00-932-3357
MSDS Number: BMBWK
=== Responsible Party ===
Company:CHEVRON
Box:4054
City:RICHMOND
State:CA
ZIP:94804
Country:US
Info Phone Num:800-582-3835
Emergency Phone Num:800-582-3835
CAGE:0AHD1
=== Contractor Identification ===
Company:CHEVRON ENVIRONMENTAL HEALTH CENTER INC
Address:15299 SAN PABLO AVE
Box:4054
City:RICHMOND
State:CA
ZIP:94804
Country:US
Phone:800-582-3835
CAGE:0AHD1
Company:CHEVRON PRODUCTS COMPANY LUBRICANTS AND SPECIALTY PRODUCTS
Address:6001 BOLLINGER CANYON RD
Box:City:SAN RAMON
State:CA
ZIP:94583
Country:US
Phone:800-414-6737 / 800-582-3835
CAGE:81230
============= Composition/Information on Ingredients =============
Name:LUBRICATING BASE OIL - MULTIPLE CAS NO INVOLVED.
Fraction by Wt: >99.0%
Name:ADDITIVES
Fraction by Wt: <1.0%
Name:FIRST AID PROC: MED ADVICE. CONSULT MED PERS BEFORE
INDUCING VOMIT. IF MED ADVICE CANNOT BE OBTAINED, THEN (SEE ING 4)
RTECS #:9999999ZZ
Name:ING 3: TAKE PERSON & PROD CNTNR TO THE NEAREST MEDICAL
EMERGENCY TREATMENT CENTER OR HOSPITAL.
RTECS #:9999999ZZ
Name:SPILL PROC: SM SPILLS USING APPROP TECHNIQUES SUCH AS
SORBENT MATLS/PUMPING. WHERE FEASIBLE & APPROP, REMOVE (ING 6)
RTECS #:9999999ZZ
Name:ING 5: CONTAM SOIL. FOLLOW PRESCRIBED PROCEDURES FOR
REPORTING & RESPONDING TO LARGER RELEASES.
RTECS #:9999999ZZ
===================== Hazards Identification =====================
LD50 LC50 Mixture:NONE SPECIFIED BY MANUFACTURER.
Routes of Entry: Inhalation:YES Skin:NO Ingestion:YES
Reports of Carcinogenicity:NTP:NO IARC:NO OSHA:NO
Health Hazards Acute and Chronic:EYE/SKIN: THIS SUBSTANCE IS NOT
EXPECTED TO CAUSE PRLNGD/SIGNIFICANT EYE IRRIT. THIS HAZ EVAL IS
BASED ON DATA FROM SIMILAR MATLS. SKIN TOX: THE SYSTEMIC TOX OF
THIS SUBSTANCE HAS NOT BEEN DETERMINED. HOWEVER, IT SHOULD BE
PRACTICALLY NON-TOX TO INTERNAL ORGANS IF IT GETS ON SKIN. THIS HAZ
EVAL (SEE EFTS OF OVEREXPOS)
Explanation of Carcinogenicity:NOT RELEVANT
Effects of Overexposure:HLTH HAZ:IS BASED ON DATA FROM SIMILAR MATLS.
RESP/INHAL: THE SYSTEMIC TOX OF THIS SUBSTANCE HAS NOT BEEN
DETERMINED. HOWEVER, IT SHOULD BE PRACTICALLY NON-TOX TO INTERNAL
ORGANS IF INHALED. THIS HAZ EVAL IS BASED ON DATA FROM SIMILAR
MATLS. INGEST: THE SYSTEMIC TOX OF THIS SUBSTANCE HAS NOT BEEN
DETERMINED.(SUPP DATA)
Medical Cond Aggravated by Exposure:NONE SPECIFIED BY MANUFACTURER.
======================= First Aid Measures =======================
First Aid:EYE:NO FIRST AID PROC ARE REQ. HOWEVER, AS A PREC FLUSH EYES
W/FRESH POTABLE WATER FOR AT LEAST 15 MIN. REMOVE CONT LENSES IF
WORN. SKIN:NO FIRST AID PROC ARE REQ. AS A PREC, WASH SKIN THORO
W/SOAP & WATER. REMOVE & WASH CONTAM CLTHG. INHAL:SINCE MATL IS
NOT EXPECTED TO BE AN IMMED INHAL PROBLEM, NO FIRST AID PROC ARE
REQ. INGEST:IF SWALLOWED, GIVE WATER/MILK TO DRINK & TELEPHONE FOR
(SEE ING 3)
===================== Fire Fighting Measures =====================
Flash Point Method:COC
Flash Point:445F,229C
Extinguishing Media:CO*2, DRY CHEMICAL, FOAM, WATER FOG.
Fire Fighting Procedures:WEAR NIOSH/MSHA APPRVD SCBA & FULL PROT EQUIP
. FOR FIRES INVOLVING THIS MATL, DO NOT ENTER ANY ENCLOSED/CONFINED
FIRE SPACE W/O PROPER PROT EQUIPMENT.
Unusual Fire/Explosion Hazard:NORMAL COMBUSTION FORMS CO*2 AND WATER
VAPOR; INCOMPLETE COMBUSTION CAN PRODUCE CO.
================== Accidental Release Measures ==================
Spill Release Procedures:THIS MATL IS NOT EXPECTED TO PRESENT ANY
ENVIRON PROBLEMS OTHER THAN THOSE ASSOC W/OIL SPILLS. STOP SOURCE
OF LEAK/RELEASE. CLEAN UP RELEASE AS SOON AS POSS. CONTAIN LIQ TO
PVNT FURTHER CONTAM OF SOIL , SURFACE WATER/GROUNDWATER. CLEAN UP
(SEE ING 5)
Neutralizing Agent:NONE SPECIFIED BY MANUFACTURER.
====================== Handling and Storage ======================
Handling and Storage Precautions:DO NOT WELD, HEAT OR DRILL CONTAINER.
RESIDUE MAY IGNITE WITH EXPLOSIVE VIOLENCE IF HEATED SUFFICIENTLY.
Other Precautions:CAUTION! DO NOT USE PRESSURE TO EMPTY DRUM OR
EXPLOSION MAY RESULT.
============= Exposure Controls/Personal Protection =============
Respiratory Protection:NO SPECIAL RESPIRATORY PROTECTION IS NORMALLY
REQUIRED. HOWEVER, IF OPERATING CONDITIONS CREATE HIGH AIRBORNE
CONCENTRATIONS, THE USE OF AN NIOSH/MSHA APPROVED RESPIRATOR IS
RECOMMENDED.
Ventilation:USE ADEQUATE VENTILATION TO KEEP THE AIRBORNE
CONCENTRATIONS OF THIS MATERIAL BELOW THE RECOMMENDED EXPOSURE
STANDARD.
Protective Gloves:IMPERVIOUS GLOVES .
Eye Protection:CHEMICAL WORKERS GOGGLES .
Other Protective Equipment:PROTECTIVE CLOTHING.
Work Hygienic Practices:NONE SPECIFIED BY MANUFACTURER.
Supplemental Safety and Health
EFTS OF OVEREXP: HOWEVER, IT SHOULD BE PRACTICALLY NON-TOX TO INTERNAL
ORGANS IF SWALLOWED. THIS HAZ EVAL IS BASED ON DATA FROM SIMILAR
MATLS. THIS PROD CONTAINS PETRO BASE OIL WHICH MAY BE REFINED BY
VARIOUS PROCESSES INCL SEVERE SOLV EXTRACTION, SEVERE
HYDROCRACKING/SEVERE HYDROTREATING.
================== Physical/Chemical Properties ==================
Spec Gravity:0.89 @15.6C
Solubility in Water:INSOLUBLE
Appearance and Odor:GREENISH-AMBER VISCOUS LIQUID.
================= Stability and Reactivity Data =================
Stability Indicator/Materials to Avoid:YES
MAY REACT WITH STRONG OXIDIZING AGENTS, SUCH AS CHLORATES, NITRATES,
PEROXIDES, ETC.
Stability Condition to Avoid:NONE SPECIFIED BY MANUFACTURER.
Hazardous Decomposition Products:NONE SPECIFIED BY MANUFACTURER.
==================== Disposal Considerations ====================
Waste Disposal Methods:PLACE CONTAMINATED MATERIALS IN DISPOSABLE
CONTAINERS AND DISPOSE OF IN A MANNER CONSISTENT WITH APPLICABLE
FEDERAL, STATE AND LOCAL REGULATIONS. CONSULT LOCAL ENVIRONMENTAL
OR HEALTH AUTHORITIES FOR APPROVED DISPOSAL OF THIS MATERIAL.
Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.
*** END OF RECORD *** |
|
|