Search   
MSDS  : MIL-H-6083E,HYDRAULIC FLUID,PETROLEUM BASE
CAS  : 64741-97-5
64742-46-7
64742-53-6
NAME  : distillates, solvent-refined light naphthenic
hydrotreated middle petroleum distillate
mineral oil, petroleum distillates, hydrotreated light
===================== Product Identification =====================

MSDS NAME:MIL-H-6083E,HYDRAULIC FLUID,PETROLEUM BASE
NIIN:00-935-9810
MSDS Number: BMTNW
=== Responsible Party ===
Company:TECHNOLUBE PRODUCTS CO
Address:5814 EAST 61ST STREET
City:LOS ANGELES
State:CA
ZIP:90040-3412
Country:US
Info Phone Num:213-928-3311
Emergency Phone Num:213-928-3311
Preparer's Name:RICHARD J. EBERHARDT
CAGE:8Y842
=== Contractor Identification ===
Company:LUBRICATING SPECIALTIES CO. TECHNOLUBE PRODUCTS DIV
Address:3365 E. SLAUSON AVE
Box:City:LOS ANGELES
State:CA
ZIP:90058
Country:US
Phone:562-776-4033; FAX:562-776-4003
CAGE:8Y842

============= Composition/Information on Ingredients =============

Name:DISTILLATES, SOLVENT-REFINED LIGHT NAPHTHENIC
CAS:64741-97-5
RTECS #:PY8041000
Fraction by Wt: <90%
Other REC Limits:5 MG/M3
OSHA PEL:5 MG/M3 (OIL MIST)
ACGIH TLV:5 MG/M3 (OIL MIST)

Name:HYDROTREATED MIDDLE PETROLEUM DISTILLATE
CAS:64742-46-7
RTECS #:JN9379645
OSHA PEL:5 MG/M3 (OIL MIST)
ACGIH TLV:5 MG/M3 (OIL MIST)

Name:MINERAL OIL, PETROLEUM DISTILLATES, HYDROTREATED LIGHT
NAPHTHENIC
CAS:64742-53-6
RTECS #:PY8036000
OSHA PEL:5 MG/M3 (OIL MIST)
ACGIH TLV:5 MG/M3 (OIL MIST)

===================== Hazards Identification =====================

Routes of Entry: Inhalation:NO Skin:YES Ingestion:YES
Reports of Carcinogenicity:NTP:NO IARC:NO OSHA:NO
Health Hazards Acute and Chronic:ACUTE: INGESTION: NOT NORMALLY
EXPECTED TO CAUSE ANY ILL EFFECTS. INHALATION: NO SIGNIFICANT
ADVERSE HEALTH EFFECTS ARE EXPECTED FOR SHORT TERM EXPOSURE. EYE:
NOT NORMALLY EXPECTED TO CAUSE ANY ILL EF FECTS. SKIN: NOT NORMALLY
EXPECTED TO CAUSE ANY ILL EFFECTS. CHRONIC: PROLONGED/REPEATED
CONTACT MAY CAUSE IRRITATION.
Explanation of Carcinogenicity:THE COMPONENTS OF THIS PRODUCT HAVE NOT
SHOWN ANY EVIDENCE OF BEING CARCINOGENIC.
Effects of Overexposure:INHALATION:OVEREXPOSURE MAY LEAD TO RESPIRATORY
IRRITATION. INGESTION:MAY CAUSE NAUSEA,VOMITING,AND DIARRHEA, ETC.
EYES:CAUSES MILD IRRITATION ON CONTACT.VAPORS MAY CAUSE TEARS/
IRRITATION. SKIN:COMPO NENTS ARE UNLIKELY TO BE ABSORBED.PROLONGED
AND REPEATED CONTACT MAY PRODUCE MILD SKIN IRRITATION AND
INFLAMATION.
Medical Cond Aggravated by Exposure:PERSONS WITH A SKIN DISORDER SHOULD
USE CAUTION WHEN HANDLING OR USING THIS PRODUCT.

======================= First Aid Measures =======================

First Aid:SKIN: REMOVE CONTAMINATED CLOTHING. WASH WITH SOAP AND WATER.
GET MEDICAL ATTENTION IF IRRITATION PERSISTS. INHALATION: REMOVE TO
FRESH AIR & RESTORE BREATHING IF NECESSARY. GET MEDICAL ATTENTION.
EYE : IMMEDIATELY FLUSH WITH WATER FOR 15 MINUTES WHILE HOLDING
EYELIDS OPEN. GET MEDICAL ATTENTION. INGESTION: GET IMMEDIATE
MEDICAL ATTENTION. DO NOT INDUCE VOMITING. NOTHING BY MOUTH IF
UNCONSCIOUS.

===================== Fire Fighting Measures =====================

Flash Point Method:PMCC
Flash Point:>199F,>93C
Extinguishing Media:USE CARBON DIOXIDE, FOAM, DRY CHEMICAL, OR WATER
FOG.
Fire Fighting Procedures:FIRE FIGHTERS SHOULD USE NIOSH APPROVED SCBA &
FULL PROTECTIVE EQUIPMENT WHEN FIGHTING CHEMICAL FIRE. USE WATER
SPRAY TO COOL NEARBY CONTAINERS EXPOSED TO FIRE.
Unusual Fire/Explosion Hazard:SLIGHTLY COMBUSTIBLE, WHEN HEATED ABOVE
FLASH POINT WILL RELEASE FLAMMABLE VAPORS WHICH CAN BURN IN OPEN OR
BE EXPLOSIVE IN CONFINED SPACES IF IGNITED.

================== Accidental Release Measures ==================

Spill Release Procedures:STOP FLOW. WIPE OR MOP UP OR ABSORB WITH
DIATOMACEOUS EARTH OR OTHER INERT MATERIAL. STORE IN APPROPRIATE
CONTAINER FOR DISPOSAL.

====================== Handling and Storage ======================

Handling and Storage Precautions:AVOID STORAGE NEAR OPEN FLAME OR OTHER
SOURCES OF IGNITION. EXCESSIVE MISTING MAY CAUSE SLIPPERY FLOORS.
PROPER FOOTWEAR REQUIRED.
Other Precautions:WASH OR TAKE SHOWER IF GENERAL CONTACT OCCURS. REMOVE
OIL-SOAKED CLTHING AND LAUNEDER BEFORE REUSE. DISCARD CONTAMINATED
LEATHER GLOVES AND SHOES.

============= Exposure Controls/Personal Protection =============

Respiratory Protection:NONE NORMALLY REQUIRED.
Ventilation:SUFFICIENT TO MAINTAIN ATMOSPHERE BELOW TLV LIMIT.
Protective Gloves:RECOMMENDED
Eye Protection:REQUIRED
Other Protective Equipment:CHEMICALLY RESISTANT BOOTS AND APRONS ARE
RECOMMENDED.
Work Hygienic Practices:WASH HANDS WITH SOAP AND WAATER BEFORE EATING,
DRINKING, OR SMOKING.
Supplemental Safety and Health
ITEM IS FOR MIL-H-6083, REV E., AMENDMENT 1. QPL TEST # H-6013.
MANUFACTURER'S CODE FOR THE ITEM/MSDS='A0700'

================== Physical/Chemical Properties ==================

HCC:V6
Boiling Pt:B.P. Text:>392F,>200C
Vapor Pres:<0.01 MM
Vapor Density:>1
Spec Gravity:0.876
Evaporation Rate & Reference:LESS THAN ETHER
Solubility in Water:NEGLIGIBLE
Appearance and Odor:RED, OILY LIQUID; PETROLEUM ODOR
Percent Volatiles by Volume:NIL

================= Stability and Reactivity Data =================

Stability Indicator/Materials to Avoid:YES
STRONG OXIDIZING AGENTS
Stability Condition to Avoid:DO NOT HEAT ABOVE FLASH POINT
Hazardous Decomposition Products:CARBON MONOXIDE AND ASPHYXIANTS.

==================== Disposal Considerations ====================

Waste Disposal Methods:DISPOSE OF WASTE IN ACCORDANCE WITH LOCAL, STATE
AND FEDERAL REGULATIONS.

Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.

*** END OF RECORD ***
Search More   
ALL PAGES On Chemical Property IN THIS GROUP
NAMECAS
KLINGER OILIT (GASKET) 12001-29-5
9003-18-3
1333-86-4
COMPRESSED ASBESTOS RUBBER GASKET MATERIAL 12001-29-5
9010-98-4
1333-86-4
9003-17-2
96-45-7
ASBESTOS FILLED SPIRAL WOUND GASKET 12001-29-5
TBA 410 12001-29-5
NUSORB G50-6X12 64365-11-3
CHEVRON UREA 57-13-6
TIN-LEAD ALLOY 7439-92-1
7440-31-5
C-100 ION EXCHANGE RESIN
ETHYL ALCOHOL,190 PROOF 64-17-5
MERCURY VAPOR LAMP H39KC-175/DX AND H33GL-4 7439-97-6
1314-62-1
7440-65-5
SODIUM DICHROMATE 7789-12-0
10588-01-9
NOKORODE SOLDERING PASTE 7646-85-7
12125-02-9
8009-03-8
MERCURY VAPOR LAMP H39KC-175/DX AND H33GL-4 7439-97-6
1314-62-1
7440-65-5
ANDEROL 786 SYN SEVERE DUTY GREASE
MULTI-PURPOSE GEAR COMPOUND
MIL-H-6083E,HYDRAULIC FLUID,PETROLEUM BASE 64741-97-5
64742-46-7
64742-53-6
LIME-A-WAY 7697-37-2
7664-38-2
D-70 DEVELOPER 67-63-0
RTV8112 110990-60-2
471-34-1
70131-67-8
METCO SPRABRONZE AA WIRE 7429-90-5
1309-37-1
7440-50-8
7429-90-5
TELLUS(R) OIL 68, SHELL CODE:65211 64742-54-7
SOUDINOX 308-15, 308L-15, 309-15, 309L-15, 13463-67-7
112945-52-5
7789-75-5
12001-26-2
7439-89-6
7440-47-3
7440-21-3
7439-96-5
7440-02-0
7439-98-7
LOW HYDROGEN LOW ALLOY COVERED ELECTRODES T 13463-67-7
7789-75-5
14808-60-7
7439-89-6
7439-96-5
7440-21-3
7439-98-7
7440-47-3
7440-02-0
MIL-L-6085B/PQ RUST PREVENTIVE 160 68608-24-4
CHANNEL MASTER CONTACT SHIELD #9100/9101 124-38-9
71-55-6
ORION APPLICATION SOLUTION PH 7.00 BUFFER 7778-77-0
7775-11-3
7732-18-5
7558-79-4
7778-50-9
SULFURIC ACID 66 DEGREE 7664-93-9
KLINGER R-52 (GASKET) 12001-29-5
9010-98-4
1333-86-4
9003-17-2
96-45-7
THYMOL 89-83-8
DTIC - DOME 4342-03-4
KENVERT,182 7786-81-4
LDC-#1 ACTIVATOR & ETCH 7732-18-5
7783-20-2
7664-93-9
ADSCO NU-PAK-TITE COMPOUND 7620-77-1
64741-53-3
1317-33-5
3452 CHEMICAL RESIST VALVE LUB 9002-84-0
ITEK CAMERA PROCESSOR FIXER 7732-18-5
7783-18-8
7757-83-7
64-19-7
1762-95-4
ITEK CAMERA PROCESSOR DEVELOPER 7732-18-5
7757-83-7
123-31-9
1310-73-2
MIL-L-6085B/PQ RUST PREVENTIVE 160 68608-24-4
0101 EMOLLIENT LOTION
DDVP 2E EMULSIFIABLE CONCENTRATE 62-73-7
64742-95-6
1330-20-7
95-63-6
98-82-8
SODIUM GLUCONATE 527-07-1
NEVAMAR LAMINATED PLASTIC
UNOCAL SUPER MOTOR OIL 10W/40 8012-95-1
BACTROL DISKS
HYDROFLUORIC ACID,ELECTRONIC AND REAGENT GR 7664-39-3
7664-93-9
DRYDENE ALL PURPOSE GEAR LUBRICANT 75W, 80W
ARCO HD GEAR OIL SAE 80W-90 64742-62-7
64742-65-0
DRYDENE ALL PURPOSE GEAR LUBRICANT 75W, 80W
HEAVY DUTY 80W/90 MIL-L-2105D 64742-57-0
64742-65-0
64742-52-5
DURALENE TUF-TEX "C" 80W90
DURALENE TUF-TEX "C" 80W90

Free MSDS Search ( Providing 250,000+ Material Properties )