LD50 LC50 Mixture:NONE SPECIFIED BY MANUFACTURER.
Routes of Entry: Inhalation:YES Skin:NO Ingestion:YES
Reports of Carcinogenicity:NTP:NO IARC:NO OSHA:NO
Health Hazards Acute and Chronic:ORAL, DERMAL & INHAL TOXICITY ARE LOW,
MILD SKIN & EYE IRRIT. CHRONIC: PROBABLE LETHAL DOSE FOR HUMANS
100M; SMALLER DOSES MAY LEAD TO SERIOUS KIDNEY INJ. TARGET ORGAN
EFFECTS: EYE HAZ (IRRITANT) KIDN EY TOXIN. OTHER DATA: REPORTED
RENAL EFTS (HUMANS): ETHYLENE GLYCOL. REPORTED REPRODUCTIVE
EFFECTS: ETHYLENE GLYCOL.
Explanation of Carcinogenicity:NOT RELEVANT
Effects of Overexposure:INGESTION: GI DISTRESS.
Medical Cond Aggravated by Exposure:RENAL DISEASE.
======================= First Aid Measures =======================
Eyes: FLUSH THORO W/WATER FOR AT LEAST 15 MINUTES. GET MED
ASSIST. SKIN: WASH CONTACT AREAS WITH SOAP & WATER. LAUNDER
CONTAMINATED CLOTHING BEFORE REUSE. INHAL: NOT EXPECTED TO BE A
PROBLEM. REMOVE T O FRESH AIR. SUPPORT BRTHG (GIVE O2/ARTF RESP).
INGEST: INDUCE VOMIT IMMED BY GIVING TWO GLASSES OF WATER &
STICKING FINGER DOWN THROAT. CALL MD, HOSP EMERG RM/POISON CNTRL
CNTNR.(SUPP DATA)
===================== Fire Fighting Measures =====================
Flash Point Method:SCC
Flash Point:139F,59C
Extinguishing Media:CO2, FOAM, DRY CHEMICAL.
Fire Fighting Procedures:WEAR NIOSH/MSHA APPRVD SCBA & FULL PROT EQUIP
. EVACUATE AREA DOWNWIND OF FIRE. COOL STORAGE DRUMS WITH WATER
SPRAY.
Unusual Fire/Explosion Hazard:FLAMMABLE LIQUID.
Spill Release Procedures:ELIM ALL IGNIT SOURCES. REMOVE LEAKING CNTNRS
TO DETACHED AREA. ABSORB ON FIRE RETARDANT TREATED SAWDUST,
DIATOMACEOUS EARTH, ETC. SHOVEL UP & DISP OF AT AN APPROP WASTE
DISP FACILITY I/A/W CURRENT AP PLIC LAWS & REGS & PROD CHARACT AT
TIMEOF DISP.
Neutralizing Agent:NONE SPECIFIED BY MANUFACTURER.
====================== Handling and Storage ======================
Handling and Storage Precautions:AVOID CONTACT W/EYES & SKIN. USE IN
WELL VENT AREA AWAY FROM ALL IGNIT SOURCES. MAY BE FATAL IF INGEST.
STORED MATLS MUST BE LABELED AS FLAMMABLE.
Other Precautions:GROUND & BOND ALL TRANS & STOR EQUIP, USE
NON-SPARKING TOOLS & EQUIP. DRUMS MUST BE GROUNDED & BONDED &
EQUIPPED W/SELF-CLOSING VALVES, PRESSURE VACUUM BUNGS & FLAME
ARRESTERS. OUTSIDE/DETACHED STOR P REF. STORE IN COOL AREA AWAY
(SUPP DATA)
Respiratory Protection:VENT REQD & EQUIPMENT MUST BE EXPLOSION PROOF.
USE AWAY FROM ALL IGNITION SOURCES. NIOSH/MSHA APPROVED RESPIRATOR
APPROPRIATE FOR EXPOSURE OF CONCERN .
Ventilation:VENT REQD & EQUIP MUST BE EXPLOSION PROOF. USE AWAY FROM
ALL IGNITION SOURCES.
Protective Gloves:IMPERVIOUS GLOVES.
Eye Protection:CHEMICAL WORKERS GOGGLES .
Other Protective Equipment:NONE SPECIFIED BY MANUFACTURER.
Work Hygienic Practices:NONE SPECIFIED BY MANUFACTURER.
Supplemental Safety and Health
FIRST AIR PROC: DO NOT INDUCE VOMIT OR GIVE ANTHING BY MOUTH TO AN
UNCONSCIOUS PERSON. OTHER PREC: FROM ALL IGNIT SOURCES. EMPTY
CONTAINERS MAY CONTAIN PRODUCT RESIDUE, INCLUDING FLAMMABLE OR
EXPLOSIV E VAPORS. DO NOT CUT, PUNCTURE OR WELD ON OR NEAR
CONTAINER.
Waste Disposal Methods:DISPOSE OF WASTE BY SUPERVISED INCINERATION IN
COMPLIANCE WITH APPLICABLE LAWS & REGULATIONS.
Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.