LD50 LC50 Mixture:NONE SPECIFIED BY MANUFACTURER.
Routes of Entry: Inhalation:YES Skin:YES Ingestion:YES
Reports of Carcinogenicity:NTP:NO IARC:NO OSHA:NO
Health Hazards Acute and Chronic:(ACUTE & CHRONIC) INHAL: DIZZINESS,
NAUSEA, HEADACHE, UNCONSCIOUSNESS. SKIN: IRRITATION, DERMATITIS.
EYE: IRRITATION.
Explanation of Carcinogenicity:NOT RELEVANT
Effects of Overexposure:SEE HEALTH HAZARDS.
Medical Cond Aggravated by Exposure:RESPIRATORY DISEASES, LIVER OR
KIDNEY DISEASES, SKIN DISORDERS.
======================= First Aid Measures =======================
First Aid:INHAL: REMOVE TO FRESH AIR. IF NECESSARY ADMINISTER
OXYGEN/ARTF RESP. SKIN: WASH THOROUGHLY WITH SOAP AND WATER. EYE:
FLUSH WITH WATER FOR AT LEAST 15 MINUTES. GET MD. INGEST: DO NOT
INDUCE VOMITING. CALL MD.
===================== Fire Fighting Measures =====================
Flash Point Method:PMCC
Flash Point:105F,41C
Lower Limits:1%
Extinguishing Media:CHEMICAL FOAM OR DRY CHEMICAL.
Fire Fighting Procedures:WEAR NIOSH/MSHA APPROVED SCBA & FULL
PROTECTIVE EQUIPMENT .
Unusual Fire/Explosion Hazard:VAPS ARE HVR/AIR; MAY TRAVEL ALONG
GROUND/ MAY BE MOVED BY VENT & IGNITED BY PILOT LIGHTS; OTHER
FLAMES, SPARKS, HEATERS, SMOKING, ELEC MOTORS/OTHER (SUPP DATA)
Respiratory Protection:IF TLV'S ARE EXCEEDED, A NIOSH/MSHA APPROVED
SCBA.
Ventilation:LOCAL EXHAUST: ADEQUATE VENTILATION. MECHANICAL (GENERAL):
EXPLOSION PROOF FAN. SPECIAL: SUFF TO MAINTAIN VAPS
Protective Gloves:RUBBER OR BUNA N.
Eye Protection:CHEMICAL WORKERS GOGGLES .
Other Protective Equipment:TO PREVENT PROLONGED SKIN CONTACT WEAR
IMPERVIOUS CLOTHING AND BOOTS.
Work Hygienic Practices:DO NOT EAT OR SMOKE DURING APPLICATION.
Supplemental Safety and Health
EXPLO HAZ: IGNITION SOURCES AT LOCATIONS DISTANT FROM MATERIAL HANDLING
POINT.
Waste Disposal Methods:ABSORB ON SAND, CLAY OR OTHER ABSORBENT MATERIAL
AND SHOVEL INTO CONTAINERS. DISPOSE BY CONTROLLED BURNING OR
AUTHORIZED LANDFILL. DISPOSAL MUST BE IN ACCORDANCE WITH FEDERAL,
STATE AND LOCAL REGULATI ONS .
Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.