Search   
MSDS  : ABLEFILM 566K
CAS  : 107-13-1
NAME  : acrylonitrile
===================== Product Identification =====================

MSDS NAME:ABLEFILM 566K
NIIN:00N027252
MSDS Number: BNLRF
=== Responsible Party ===
Company:ABLESTIK LABS
Address:20021 SUSANA RD
Box:9067
City:RANCHO DOMINGUEZ
State:CA
ZIP:90221
Country:US
Info Phone Num:213-764-4600
Emergency Phone Num:213-764-4600
CAGE:9V874
=== Contractor Identification ===
Company:ABLESTIK LABS
Address:833 WEST 182ND ST
Box:9067
City:GARDENA
State:CA
ZIP:90248
Country:US
Phone:213-532-9341
CAGE:9V874
Company:ABLESTIK LABS SUB OF NATIONAL STARCH AND CHEMICAL
Address:20021 SUSANA RD
Box:City:COMPTON
State:CA
ZIP:90221
Country:US
Phone:310-764-4600
CAGE:21109

============= Composition/Information on Ingredients =============

Name:ACRYLONITRILE
CAS:107-13-1
RTECS #:AT5250000
Fraction by Wt: <10% PPM
OSHA PEL:SEE 1910.1045
ACGIH TLV:S, 2 PPM;A2 9394
EPA Rpt Qty:100 LBS
DOT Rpt Qty:100 LBS

===================== Hazards Identification =====================

LD50 LC50 Mixture:NONE SPECIFIED BY MANUFACTURER.
Routes of Entry: Inhalation:YES Skin:YES Ingestion:YES
Reports of Carcinogenicity:NTP:YES IARC:YES OSHA:YES
Health Hazards Acute and Chronic:ACUTE: SEE SYMPTOMS OF OVEREXPOSURE.
CHRONIC: ACRYLONITRILE IS CONSIDERED TO BE CARCINOGENIC.
Explanation of Carcinogenicity:ACRYLONITRILE: ANTICIPATED TO BE A
CARCINOGEN (NTP), GROUP 2B (IARC), OSHA-REGULATED.
Effects of Overexposure:INHAL: NOT LIKELY TO PRODUCE AN ADVERSE EFT DUE
TO ITS LOW VOLATILITY. SKIN: PROLONGED OR REPEATED CONTACT MAY
CAUSE IRRITATION TO SENSITIVE INDIVIDUALS. EYES: SHOULD NOT CAUSE
IRRITATION DUE TO ITS L OW VAPOR PRESSURE. INGEST: INFO IS NOT
AVAILABLE, HOWEVER, SLIGHT POTENTIAL FOR ORAL TOXICITY IS EXPECTED.
Medical Cond Aggravated by Exposure:NONE SPECIFIED BY MANUFACTURER.

======================= First Aid Measures =======================

First Aid:EYE: FLUSH WITH WATER FOR AT LEAST 15 MIN. SEEK MD ATTENTION.
SKIN: WASH IMMEDIATELY WITH SOAP AND WATER. IF IRRITATION PERSISTS,
SEEK MEDICAL ATTENTION IMMEDIATELY. INHAL: REMOVE TO FRESH AIR
IMMEDIA TELY. INGEST: SEEK MEDICAL ATTENTION IMMEDIATELY.

===================== Fire Fighting Measures =====================

Flash Point Method:COC
Flash Point:>400F,>204C
Extinguishing Media:CARBON DIOXIDE, FOAM, DRY CHEMICAL.
Fire Fighting Procedures:WEAR NIOSH/MSHA APPROVED SCBA AND FULL
PROTECTIVE EQUIPMENT .
Unusual Fire/Explosion Hazard:NONE KNOWN.

================== Accidental Release Measures ==================

Spill Release Procedures:SWEEP UP AND COLLECT IN AN APPROPRIATE
CONTAINER FOR DISPOSAL.
Neutralizing Agent:NONE SPECIFIED BY MANUFACTURER.

====================== Handling and Storage ======================

Handling and Storage Precautions:STORE FROZEN AT ALL TIMES.
Other Precautions:AVOID CONTACT WITH SKIN, EYES, AND CLOTHING. GOOD
HOUSEKEEPING IS REQUIRED. AVOID INHALATION OF VAPORS.

============= Exposure Controls/Personal Protection =============

Respiratory Protection:USE NIOSH/MSHA APPROVED ORGANIC VAPOR RESPIRATOR
IF NEEDED.
Ventilation:USE ADEQUATE VENTILATION. LOCAL EXHAUST IS RECOMMENDED WHEN
APPROPRIATE TO CONTROL EMPLOYEE'S EXPOSURE.
Protective Gloves:RUBBER GLOVES.
Eye Protection:CHEMICAL WORKERS GOGGLES .
Other Protective Equipment:PROTECTIVE EQUIPMENT TO COVER EXPOSED AREAS.
Work Hygienic Practices:VENT CURING OVEN TO OUTDOORS.
Supplemental Safety and Health
CNDTNS (POLYM): SHOULD BE USED WITH CAUTION UPON CURING. VENT CURING
OVEN TO OUTDOORS.

================== Physical/Chemical Properties ==================

HCC:N1
Spec Gravity:2.3
Evaporation Rate & Reference:NON-VOLAT SOLID (BUAC=1)
Solubility in Water:INSOLUBLE
Appearance and Odor:WHITE FILM, ODORLESS
Percent Volatiles by Volume:<1(WT)

================= Stability and Reactivity Data =================

Stability Indicator/Materials to Avoid:YES
STRONG OXIDIZING AGENTS AND STRONG LEWIS OR MINERAL ACIDS.
Stability Condition to Avoid:HEAT PRIOR TO CURE.
Hazardous Decomposition Products:CARBON MONOXIDE, ALDEHYDES, AND ACIDS.
POSSIBLE FORMATION OF CYANIDE COMPOUNDS UPON INCOMPLETE COMBUSTION.
Conditions to Avoid Polymerization:EXCESSIVE HEAT. IF PROD IS NOT USED
FOR THIN BLOND LINE APPLICATN, VIOLENT CHEM REACTION CAN RESULT.
PROD (SUPP DATA)

==================== Disposal Considerations ====================

Waste Disposal Methods:DISPOSE IN APPROVED CHEMICAL DISPOSAL AREA OR IN
A MANNER WHICH COMPLIES WITH ALL LOCAL, STATE AND FEDERAL
REGULATIONS.

Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.

*** END OF RECORD ***
Search More   
ALL PAGES On Chemical Property IN THIS GROUP
NAMECAS
RUSTMASTER HIGH-GLOSS OIL ENAMEL 500 SERIES 100-41-4
64742-47-8
64742-88-7
13463-67-7
68459-17-6
66070-62-0
RUSTMASTER HIGH-GLOSS OIL ENAMEL 500 SERIES 64742-16-1
67746-08-1
7429-90-5
64742-47-8
64742-89-8
PROFORMANCE FOUNTAIN CONCENTRATE, 4-1185 111-76-2
67-63-0
7664-38-2
107-21-1
56-81-5
PHOTOMASTER FOUNTAIN CONCENTRATE, 4-1195 107-21-1
7631-86-9
112-27-6
PHOTOMASTER STABILIZER, 4-1198 1310-58-3
PHOTOMASTER ETCH, 4-1094 67-63-0
1310-73-2
INK ROLLER CLEANER, 4-4983 8008-20-6
PC-6/7 CARTRIDGE BLACK 1317-61-9
CERIC AMMONIUM NITRATE, C248500 16774-21-3
CALCIUM ACETATE MONOHYDRATE, C46500 5743-26-0
BRUCINE SULFATE HEPTAHYDRATE, B391I25 5787-00-8
BROMOBENZENE, B2531 108-86-1
METAPHOSPHORIC ACID, PX1004 37267-86-0
10361-03-2
SOLID COLOR ACRYLIC STAIN, A2000 107-21-1
25265-77-4
BUSAN METAL & WOOD PRIMER, 95 107-21-1
STARTING FLUID J.I. CASE 10.4 OZ 142-82-5
64742-53-6
119-47-1
124-38-9
60-29-7
STARTING FLUID J.I. CASE 7.8 OZ 124-38-9
60-29-7
142-82-5
64742-53-6
119-47-1
NUXTRA LTD CATALYST, 0116030 8052-41-3
149-57-5
NUODEX MANGANESE 6%, 0113010 64742-95-6
15956-58-8
1330-20-7
95-63-6
1336-93-2
PBXW-7 MOD 1 121-82-4
3058-38-6
PBXW-7 TYPE 2 121-82-4
3058-38-6
MINOLTA CLEAR DISPERSANT, 8906-202-01 64742-48-9
SPRAY FINISH, 2900 GLOSS WHITE 111-76-2
108-88-3
64742-95-6
71-36-3
64742-89-8
67-64-1
74-98-6
106-97-8
ABLEFILM 566K 107-13-1
ABLEBOND 967-1 2425-79-8
9046-10-0
7440-22-4
107-13-1
106-89-8
ABLEBOND 7600T 107-13-1
1344-28-1
104-78-9
25068-38-6
MPD 1080-2 G RED 1345-09-1
140-31-8
25036-25-3
TEST REAGENT, 10001 77-09-8
67-56-1
TEST REAGENTS, 10003 7664-93-9
TEST REAGENT, 10015 547-58-0
TEST REAGENTS, 10029 7761-88-8
SEISMOGRAPH ELECTRIC BLASTING CAPS 78-11-5
13424-46-9
7429-90-5
7439-92-1
INSTANTANEOUS ELECTRIC BLASTING CAPS 78-11-5
13424-46-9
7429-90-5
7439-92-1
CHEMTREAT BL-180 7632-00-0
1330-43-4
SPRAY FINISH, 2915 PEPPER ORANGE 67-64-1
74-98-6
106-97-8
111-76-2
108-88-3
64742-89-8
71-36-3
8052-41-3
SPRAY FINISH, 2916 SPANISH RED 111-76-2
108-88-3
64742-89-8
71-36-3
8052-41-3
67-64-1
74-98-6
106-97-8
SPRAY FINISH, 2920 GOLDENROD 111-76-2
108-88-3
64742-89-8
71-36-3
8052-41-3
67-64-1
74-98-6
106-97-8
SPRAY FINISH, 2901 FLAT WHITE 8052-41-3
1330-20-7
64742-95-6
64742-89-8
71-36-3
67-64-1
74-98-6
106-97-8
108-88-3
SPRAY FINISH, 2903 FLAT ANTIQUE WHITE 108-88-3
8052-41-3
1330-20-7
64742-95-6
64742-89-8
71-36-3
67-64-1
74-98-6
106-97-8
THYMOL BLUE, T4165 76-61-9
FERRIC AMMONIUM CITRATE, I 72500 1185-57-5
LITHIUM NITRATE, L132500 7790-69-4
FERRIC-FERROUS OXIDE, I119500 1317-61-9
SATINHIDE LATES NEUTRAL BASE, 88-587 471-34-1
14808-60-7
7732-18-5
YELLOW OXIDE COLORANT C, 96-3 51274-00-1
7732-18-5
107-21-1
107-41-5
400 EPOXY COATING RESIN 107-98-2
64742-95-6
DEVARDA'S ALLOY, 2680 7429-90-5
7440-50-8
7440-66-6
CATION EXCHANGE RESIN, DOWEX HCR-W2, (SUPP 69011-21-8
7732-18-5
BISMUTH TRIOXIDE, 1159 1304-76-3
BISMUTH TRIOXIDE, 5295 1304-76-3

Free MSDS Search ( Providing 250,000+ Material Properties )