======================= First Aid Measures =======================
First Aid:FUMES:MOVE PERSON TO WELL VENTILATED AREA. RESTORE BREATHING.
GET MEDICAL ATTN. SKIN CNTCT:WIPE W/CLEAN CLOTH, WASH THOROUGHLY
W/SOAP & WATER. EYE CNTCT:FLUSH THOROUGHLY W/WATER. GET MEDICAL
ATTN.
===================== Fire Fighting Measures =====================
Flash Point:20F (TCC)
Lower Limits:1.2
Extinguishing Media:CO*2,DRY CHEMICAL OR FOAM
Unusual Fire/Explosion Hazard:AVOID HEAT, SPARK & OPEN FLAME. EXTREME
HEAT/FIRE:CLSD CONTNR MAY EXPLODE. DO NOT APPLY TO HOT SURF
Spill Release Procedures:REMOVE ALL SOURCES OF IGNITION.VENTILATE
AREA.MOP SPILLS W/INERT ABSORBENT.BURN SWEEPINGS IN A SAFE AREA
(MFR RECM)-MUST BE IAW LOCAL,STATE & FEDERAL REGULATIONS.
====================== Handling and Storage ======================
Handling and Storage Precautions:MFR RECM STORE BELOW 100F. KEEP
CONTAINERS CLOSED & AWAY FROM HEAT & OPEN FLAME.
Other Precautions:AVOID PROLONGED CONTACT W/SKIN & BREATHING VAPORS OR
SPRAY MIST.DO NOT TAKE INTERNALLY.
Respiratory Protection:OPEN,RESTRICT VENTS & CLOSED AREAS-USE
NIOSH/MSHA APPRVD EQUIP.
Ventilation:PROVIDE DILUTION VENT OR LOCAL EXHAUST TO KEEP VAP BELOW
TLV
Protective Gloves:SOLVENT RESIST
Eye Protection:SPLASH PROOF GOGGLES
Supplemental Safety and Health
VAP PRESS:70.0 BASED ON ONE CHEM IN PROD-MEK. SPEC FIRE PROC:USE H*2O
SPRAY TO COOL CLSD CONTNR EXPOS TO EXTRM HEAT TO PREVENT PRESS
BUILD-UP.
Waste Disposal Methods:DO NOT INCINERATE IN CLOSED CONTAINERS.MUST BE
IAW FLOCAL,STATE & FEDERAL REGULATIONS.
Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.