Search   
MSDS  : LEAD-ACID CELL (ANTIMONY), MODEL NO. 18-75C
CAS  : 7439-92-1
7440-36-0
1309-60-0
7664-93-9
NAME  : lead (sara iii)
antimony (sara iii)
lead(iv) oxide
sulfuric acid (sara iii)
none hazardous ients
===================== Product Identification =====================

MSDS NAME:LEAD-ACID CELL (ANTIMONY), MODEL NO. 18-75C
NIIN:01-135-2777
MSDS Number: BNWCL
=== Responsible Party ===
Company:GNB INC INDUSTRIAL BATTERY DIV WOODLAKE CORP PARK
Address:829 PARKVIEW BOULEVARD
City:LOMBARD
State:IL
ZIP:60148-3249
Country:US
Info Phone Num:708-629-5200
Emergency Phone Num:708-629-5200
Preparer's Name:JAMES B. DOE, P.E.
CAGE:88219
=== Contractor Identification ===
Company:EXIDE TECHNOLOGIES INC CO, GNB INDUSTRIAL POWER DIV
Address:829 PARKVIEW BOULEVARD
Box:City:LOMBARD
State:IL
ZIP:60148-3249
Country:US
Phone:800-872-0471/630-691-7841
CAGE:88219

============= Composition/Information on Ingredients =============

Name:LEAD (SARA III)
CAS:7439-92-1
RTECS #:OF7525000
Fraction by Wt: 51.4%
Other REC Limits:NONE SPECIFIED
OSHA PEL:0.05 MG/M3;1910.1025
ACGIH TLV:0.15 MG/M3;DUST 9192
EPA Rpt Qty:1 LB
DOT Rpt Qty:1 LB

Name:ANTIMONY (SARA III)
CAS:7440-36-0
RTECS #:CC4025000
Fraction by Wt: 1.0%
Other REC Limits:NONE SPECIFIED
OSHA PEL:0.5 MG/M3
ACGIH TLV:0.5 MG SB/M3; 9192
EPA Rpt Qty:5000 LBS
DOT Rpt Qty:5000 LBS

Name:LEAD(IV) OXIDE
CAS:1309-60-0
RTECS #:OG0700000
Fraction by Wt: 20.8%
Other REC Limits:NONE SPECIFIED

Name:SULFURIC ACID (SARA III)
CAS:7664-93-9
RTECS #:WS5600000
Fraction by Wt: 18.6%
Other REC Limits:NONE SPECIFIED
OSHA PEL:1 MG/M3
ACGIH TLV:1 MG/M3; 9192
EPA Rpt Qty:1000 LBS
DOT Rpt Qty:1000 LBS

Name:NONE HAZARDOUS INGREDIENTS
RTECS #:9999999ZZ
Fraction by Wt: 8.2%
Other REC Limits:NONE SPECIFIED

===================== Hazards Identification =====================

Routes of Entry: Inhalation:NO Skin:NO Ingestion:NO
Reports of Carcinogenicity:NTP:NO IARC:NO OSHA:NO

======================= First Aid Measures =======================

First Aid:EYES- IMMEDIATELY FLUSH WITH WATER AND CONTINUE FLUSHING FOR
15 MIN. GET MEDICAL ATTENTION PROMPTLY. SKIN- PROMPTLY WASH THE
EXPOSED SKIN WITH SOAP AND WATER. GET MEDICAL ATTENTION.
INHALATION- REMO VE PERSON TO FRESH AIR. IF BREATHING ISSTOPPED,
PERFORM ARTIFICIAL RESPIRATION. GET MEDICAL ATTENTION IMMEDIATELY.
INGESTION- GET MEDICAL ATTENTION IMMEDIATELY. INGEST LARGE
QUANTITIES OF WATER.

===================== Fire Fighting Measures =====================

Lower Limits:4, HYDROGEN
Upper Limits:75, HYDROGEN
Extinguishing Media:DRY CHEMICAL
Fire Fighting Procedures:IF ELECTROLYTE IS EXPOSED DURING A FIRE, DO
NOT COVER OR SPLASH WITH DRY CHEMICAL.
Unusual Fire/Explosion Hazard:KEEP SPARKS AND FLAMES AWAY FROM CELLS.
HYDROGEN AND OXYGEN GASES ARE GENERATED DURING CHARGING.

================== Accidental Release Measures ==================

Spill Release Procedures:APPLY CAUSTIC SODA OR EQUIVALENT TO NEUTRALIZE
ELECTROLYTE.
Neutralizing Agent:CAUSTIC SODA.

====================== Handling and Storage ======================

Handling and Storage Precautions:AVOID DROPPING OR BUMPING CELLS. DO
NOT STORE CELLS ABOVE 130F. MAINTAIN CHARGE AND ELECTROLYTE IN
STORED CELLS.
Other Precautions:DO NOT SHORT CIRCUIT CELL AS THIS CAN RESULT IN
EXPLOSION AN/OR CELL DAMAGE.

============= Exposure Controls/Personal Protection =============

Respiratory Protection:NONE NORMALLY REQUIRED.
Ventilation:MECHANICAL EXHAUST TO FRESH AIR.
Protective Gloves:RUBBER
Eye Protection:GOGGLES OR FACE SHIELD.
Other Protective Equipment:RUBBER BOOTS, RUBBER APRON, AND POLYESTER
CLOTHING.
Work Hygienic Practices:WASH HANDS AND EQUIPMENT WITH WATER AFTER USE.
Supplemental Safety and Health
NONE

================== Physical/Chemical Properties ==================

HCC:C1
Appearance and Odor:BATTERY

================= Stability and Reactivity Data =================

Stability Indicator/Materials to Avoid:YES
Stability Condition to Avoid:EXCESSIVE OVERCHARGING WHICH CAN GENERATE
SULFUR OXIDES, HYDROGEN SULFIDE, ETC.
Hazardous Decomposition Products:THERMAL DECOMPOSITION RELEASES SULFUR
OXIDE, HYDROGEN SULFIDE, AND STIBINE (ANTIMONY HYDRIDE).

==================== Disposal Considerations ====================

Waste Disposal Methods:NEUTRALIZED ELECTROLYTE MAY BE DISPENSED IN
SEWER SYSTEM IF LOCAL REGULATIONS PERMIT. DELIVER DISCARDED CELLS
TO QUALIFIED BATTERY WASTE HANDLING SERVICE.

Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.

*** END OF RECORD ***
Search More   
ALL PAGES On Chemical Property IN THIS GROUP
NAMECAS
UXF/G 18895-WIDE RANGE D 67-56-1
WIDE RANGE PH INDICATOR SOLUTION 67-63-0
7732-18-5
GELL CELL/DYNASTY/GELLED OR ABSORBED ELECTR 7439-92-1
1309-60-0
7446-14-2
7664-93-9
URALITE 3139,POTTING COMPOUND,PART A 5124-30-1
112945-52-5
68310-52-1
URALITE 3139,POTTING COMPOUND,PART B 112945-52-5
101-77-9
13463-67-7
25214-70-4
69178-40-1
872-50-4
2481-94-9
85-83-6
K03B111AA-GT1 7440-02-0
7440-43-9
1310-58-3
GASKET 12001-29-5
7440-02-0
LEAD-ACID CELL (ANTIMONY), MODEL NO. 18-75C 7439-92-1
7440-36-0
1309-60-0
7664-93-9
IBM IT-34 TONER 25608-33-7
25119-62-4
70983-74-3
1333-86-4
68909-20-6
NICKEL CADMIUM STORAGE BATTERY 1310-58-3
8675B GASKET 12001-29-5
P/N 9151-45
KWIK KOLD 7732-18-5
6484-52-2
DPD 1 TABLET, 08576 3002-83, 08576 3003-19, 10043-35-3
PROPYLENE 115-07-1
74-98-6
HEXAFLOC M-20,COAGULANT WATER (SEE SUPP DA)
SODIUM HEXAMETAPHOSPHATE 68915-31-1
P/N P24 5 LEAD ACID BATTERIES 7664-93-9
1309-60-0
7439-92-1
HEXAFLOC M-20
AIC HDM-11 GREASE
CARBON DIOXIDE 124-38-9
P/N 4120-39, SAVIN 765 DISPERSANT 64742-48-9
AIR LUBE 10W/NE
PROPANE 74-98-6
25635-88-5
NK 2528-1 12001-29-5
SILICA GEL 63231-67-4
LEAD ACID BATTERY 7664-93-9
7440-36-0
7440-38-2
7440-70-2
7440-31-5
9003-07-4
9003-53-6
9003-54-7
9003-56-9
9003-55-8
9002-86-2
EPK 1C PART A 14807-96-6
13463-67-7
EPK 1C PART B 14807-96-6
7631-86-9
111-40-0
AVCOAT 8039CCF,COMPONENT II, (SEE SUPP) 1338-23-4
7722-84-1
131-11-3
78-93-3
HT 424 THIXOTROPIC PASTE,PART B,ADHESIVE 7429-90-5
112945-52-5
GASKET 12001-29-5
MOLYBDENUM DISULFIDE LUBRICANT,MOLYDAG 210 1317-33-5
1330-20-7
67-63-0
P/N 72-00035 PART I,ADHESIVE 7440-02-0
127-18-4
108-88-3
9016-00-6
68988-56-7
GASKET P/N 107E4517-200 12001-29-5
AMPLI-FOAM 1310-73-2
7631-90-5
67-63-0
ANT-ICING AND D-ICING DEFROSTING FLUID 57-55-6
MANU-KLENZ 25155-30-0
68603-42-9
SCOTCH BRAND POLYURETHANE PROTECTIVE TAPE ( 67-63-0
108-88-3
68989-76-4
T-180, 1,1,2-TRICHLORO-1,2,2-TRIFLUORETHANE 76-13-1
1142577 REFLOTRON CLEAN AND CHECK KIT 67-63-0
AIR LUBE 10W/NR,P/N-60538 64742-53-6
478192 CALIBRATION CHECK GAS 74-82-8
7782-44-7
7727-37-9
8755-39 RPR TEST KIT 115
CERAMCO SHOULDER POWDER LIQUID 64-17-5
7732-18-5
PVC GRAPHITE TILE 75-01-4
108-05-4
7782-42-5
HIBICLENS 18472-51-0
67-63-0
7732-18-5
CERAMCO II PORCELAIN 68476-25-5
DE-SOLV-IT,CLEANER/SOLVENT 5989-27-5
8006-54-0
CERAMCO II PORCELAIN 68476-25-5

Free MSDS Search ( Providing 250,000+ Material Properties )
Chemcas.com| Ads link:todaystock.net