MSDS  : 550 COLD-SOLVENT COAT REMOVER
CAS  : 108-88-3
64-18-6
1319-77-3
75-09-2
NAME  : toluene
formic acid
cresol; (cresylic acid)
methane, dichloro-; (methylene chloride) (dichloromethane)
===================== Product Identification =====================

MSDS NAME:550 COLD-SOLVENT COAT REMOVER
NIIN:00N037055
MSDS Number: BQRNL
=== Responsible Party ===
Company:FREMONT INDUSTRIES INC
Address:4400 VALLEY INDUSTRIAL PARK
City:SHAKOPEE
State:MN
ZIP:55379
Country:US
Info Phone Num:612-445-4121
Emergency Phone Num:612-445-4121
Preparer's Name:DEBORAH A. TREWARTHA
CAGE:7R331
=== Contractor Identification ===
Company:FREMONT INDUSTRIES INC
CAGE:7R331

============= Composition/Information on Ingredients =============

Name:TOLUENE
CAS:108-88-3
RTECS #:XS5250000
Fraction by Wt: 1-10%
OSHA PEL:200 PPM/150 STEL
ACGIH TLV:50 PPM; 9293
EPA Rpt Qty:1000 LBS
DOT Rpt Qty:1000 LBS

Name:FORMIC ACID
CAS:64-18-6
RTECS #:LQ4900000
Fraction by Wt: 1-10%
OSHA PEL:5 PPM
ACGIH TLV:5 PPM, 10 STEL
EPA Rpt Qty:5000 LBS
DOT Rpt Qty:5000 LBS

Name:CRESOL; (CRESYLIC ACID)
CAS:1319-77-3
RTECS #:GO5950000
Fraction by Wt: 1-10%
OSHA PEL:5 PPM, S
ACGIH TLV:5 PPM, S
EPA Rpt Qty:1000 LBS
DOT Rpt Qty:1000 LBS

Name:METHANE, DICHLORO-; (METHYLENE CHLORIDE) (DICHLOROMETHANE)
CAS:75-09-2
RTECS #:PA8050000
Fraction by Wt: >60%
OSHA PEL:500 PPM; 1000, C
ACGIH TLV:50 PPM
EPA Rpt Qty:1000 LBS
DOT Rpt Qty:1000 LBS

===================== Hazards Identification =====================

LD50 LC50 Mixture:NONE SPECIFIED BY MANUFACTURER.
Routes of Entry: Inhalation:YES Skin:YES Ingestion:YES
Reports of Carcinogenicity:NTP:YES IARC:YES OSHA:NO
Health Hazards Acute and Chronic:ACUTE: IRRIT OF SKIN & RESP TRACT.
DIRECT CONT CAN CAUSE SEV EYE/SKIN INJURY. RED, BURN SENSATION,
TEAR, INFLAMM, LIGHT HEADEDNESS, DIZZ, COUGH, NAUS. NOTE: TOLUENE
(CAS# 108-88-3) APPEARS ON NAVY LIS T OF OCCUP CHEMICAL REPROD
HAZARD. CONSULT WITH APPROP PROFESSIONALS CONCERNING LATEST HAZ
LIST INFO (EFTS OF OVEREXP)
Explanation of Carcinogenicity:METHYLENE CHLORIDE: GROUP 2B(IARC),IARC
MONOGRAPHS SUPPLEMENT VOL 7, PAGE 194, 1987. ANTICIPATED TO BE
CARCIN (SUP DAT)
Effects of Overexposure:HLTH HAZ: & SAFE HNDLG & EXPOS RECOM.
CHLOROCARBON MATLS HAVE PRDCD SENSIT OF MYOCARDIUM TO EPINEPHRINE
IN LAB ANIMALS & COULD HAVE SIMILAR EFT IN HUMANS. ADRENOMIMETICS
(E.G., EPINEPHRINE) MAY BE CONTRAINDICATED EXCEPT FOR
LIFE-SUSTAINING USES IN HUMANS ACUTELY OR CHRONICALLY EXPOSED TO
CHLOROCARBONS .
Medical Cond Aggravated by Exposure:NOT AVAILABLE.

======================= First Aid Measures =======================

First Aid:(IMPORTANT TO HAVE WATER READILY AVAIL WHERE PROD IS HNDLD).
EYES: IMMED FLUSH WITH WATER CONTINOUSLY FOR @ LST 15 MIN. CONT
PHYS IMMED. SKIN: FLUSH W/PLENTY OF WATER. INHAL: SEEK FRESH AIR.
IF IRRIT PERSISTS OBTAIN MED ATTN. INGEST: DRINKPLENTY OF WATER &
INDUCE VOMIT. KEEP AIRWAY CLEAR IF ASPIRATED CHEM PNEUM MAY
DEVELOP. CONT PHYS IMMED.

===================== Fire Fighting Measures =====================

Flash Point:NOT FLAMMABLE
Extinguishing Media:WATER, FOAM, CARBON DIOXIDE, DRY CHEMICAL.
Fire Fighting Procedures:WEAR NIOSH/MSHA APPRVD PRESS DEMAND SCBA &
FULL PROT EQUIP. USE WATER SPRAY TO COOL CONTRS NEAR FIRE AREA.
Unusual Fire/Explosion Hazard:PROD CNTN METHYLENE CHLORIDE-MAY FORM
EXPLOSIVE MIXTURE IN ATM OF HIGH OXYGEN CONTENT. THERMAL DECOMP
PROD MAY INC HCL AND PHOSGENE .

================== Accidental Release Measures ==================

Spill Release Procedures:CLEAR OUT ALL PERS OUT OF SPILL AREA. WEAR ALL
PROT EQUIP WHEN HNDLG SPILLS/LEAKS. DIKE & SCOOP INTO SUITABLE
CONTR. USE ABSORB MATL/DRY MOP TO PICK UP REMAINDER. PLACE INTO
DESIGNATED CHEMIAL WASTE C ONTAINER FOR PROPER DISPOSAL.
Neutralizing Agent:NONE SPECIFIED BY MANUFACTURER.

====================== Handling and Storage ======================

Handling and Storage Precautions:WEAR ALL PROT EQUIP WHEN HNDLG PROD.
KEEP CONTR CLSD WHEN NOT IN USE. DO NOT GET IN EYES.
Other Precautions:DO NOT TAKE INTERNALLY. AVOID BRTHG OF VAPS. DO NOT
STORE/USE NEAR HEAT/SPARKS/OPEN FLAME. NO SMOKING IN AREA OF USE.
DO NOT USE IN GEN VICIN OF ARC WELD, OPEN FLAMES/HOT SURF. HEAT
&/OR UV RADIA MAY CAUSE FORM OF HCL &/OR PHOSGENE.

============= Exposure Controls/Personal Protection =============

Respiratory Protection:NIOSH/MSHA APPROVED RESPIRATOR FOR ORGANIC
VAPORS TC-23C-123, I.E. 3M #8712 OR SUPPLIED AIR.
Ventilation:LOCAL EXHAUST: AS NEEDED TO CTL VAPS.
Protective Gloves:RUBBER.
Eye Protection:CHEM WORK GOG OR FULL LNGTH FSHLD.
Other Protective Equipment:RUBBER APRON, RUBBER BOOTS, EYE WASH &
SAFETY SHOWER.
Work Hygienic Practices:WASH THORO AFTER USE. REMOVE & WASH SOILED
CLTHG BEFORE REUSE. USE ONLY AS DIRECTED. USE ONLY IN WELL VENTD
WORK AREAS.
Supplemental Safety and Health
HAZ DECOMP: PHOSGENE. DO NOT BURN/USE ON HOT METALS. DO NOT USE NEAR
OPEN FLAME. EXPLAN OF CARCINOGENICITY: (NTP), NTP SIXTH ANNUAL
REPORT ON CARCINOGENS, SUMMARY, 1991. .

================== Physical/Chemical Properties ==================

HCC:C1
Boiling Pt:B.P. Text:104F,40C
Spec Gravity:1.21(H*2O=1)
Solubility in Water:EMULSIFIERS
Appearance and Odor:CLEAR BROWN LIQUID; ACRID ODOR.
Percent Volatiles by Volume:77

================= Stability and Reactivity Data =================

Stability Indicator/Materials to Avoid:YES
STRONG OXIDIZING AGENTS AND STRONG ALKALINE MATERIAL.
Stability Condition to Avoid:NONE.
Hazardous Decomposition Products:@ HIGH TEMP, PROD DECOMP TO GIVE OFF
HYDROCHLORIC ACID AS GAS PLUS OTHER TOX & IRRITATING VAPS SUCH AS
(SUPP DATA)

==================== Disposal Considerations ====================

Waste Disposal Methods:DISPOSE OF COMPLYING WITH LOCAL, STATE OR
FEDERAL REGULATIONS GOVERNING HEALTH AND POLLUTION. SEND SOLVENT TO
LICENSED RECLAIMER.

Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.

*** END OF RECORD ***
Search More   
ALL PAGES On Chemical Property IN THIS GROUP
NAMECAS
GLID-GUARD GLID-ZINC INORGANIC COATING, 553 67-63-0
GLID-GUARD GLID-ZINC INORGANIC COATING, 553 7440-66-6
1314-13-2
7439-92-1
THINNER, GTA407 1330-20-7
108-10-1
550 COLD-SOLVENT COAT REMOVER 108-88-3
64-18-6
1319-77-3
75-09-2
5006 COLD SOLVENT PAINT STRIPPER 108-88-3
67-56-1
111-76-2
64-18-6
75-09-2
7664-39-3
5007 COLD SOLVENT PAINT STRIPPER ADDITIVE 7664-39-3
111-76-2
67-56-1
75-09-2
QUICK BILD II 100-42-5
13463-67-7
7727-43-7
1480-96-6
CREME HARDNER 94-36-0
85-68-7
26027-38-3
471-34-1
7631-86-9
1317-61-9
51274-00-1
VARAMIDE A7, 650-135 93-83-4
111-42-2
SET INSTANT CONCRETE 65997-15-1
14808-60-7
EMBEGUARD CR PART A (FORMERLY CONCRESIVE 13 25068-38-6
4-METHYL-2-PENTANONE HEXONE; METHYL ISOBUTY 108-10-1
N,N-DIMETHYLACETAMIDE DMAC, 0400357 127-19-5
PROLINK VANDALISM SPRAY 18 OZ, 870 9016-45-9
68476-85-7
75-09-2
127-18-4
108-88-3
VOC INTERNAL STANDARDS MIX, 48835 74-97-5
540-36-3
108-90-7
67-56-1
ZEST POT & PAN DETERGENT, 196745 7758-29-4
1310-73-2
27176-87-0
26027-38-3
7732-18-5
DYNALOY 350 25085-50-1
7440-22-4
1330-20-7
109-86-4
111-76-2
METALPHOTO POLISH 63148-62-9
61790-53-2
7732-18-5
64742-88-7
61790-12-3
BORAX 22.820 1303-96-4
HYPLAR MODELING PASTE AND EXTENDER 9003-01-4
132-27-4
471-34-1
9004-67-5
WEATHERPROOF ALUMINUM PAINT, 137 7429-90-5
8052-41-3
63393-89-5
WEATHERPROOF ALUMINUM PAINT, C137 7429-90-5
8052-41-3
63393-89-5
ALKYD PRIMER SEALER, 200 12174-11-7
14808-60-7
13463-67-7
14807-96-6
471-34-1
7631-86-9
8052-41-3
ALKYD PRIMER SEALER, C200 8052-41-3
12174-11-7
14808-60-7
13463-67-7
14807-96-6
471-34-1
7631-86-9
INTERGARD HS UNIV EPOXY HAZE GRAY, FPK705 71-36-3
110-43-0
25068-38-6
EPOXY STEEL HARDENER 1 OZ, 48105 1317-65-3
7727-43-7
14807-96-6
98-00-0
68410-23-1
EPOXY STEEL HARDENER 5 OZ, 48171 1317-65-3
7727-43-7
14807-96-6
98-00-0
68410-23-1
PAINT PRODUCT, 0V81016184A011 1330-20-7
14807-96-6
71-36-3
108-10-1
TRAFFIC-LINE INT-EXT WATER BASED TRAFFIC (S 1336-21-6
7732-18-5
1317-65-3
13463-67-7
12001-26-2
111-76-2
14808-60-7
TRAFFIC-LINE INT-EXT WATER BASED TRAFFIC (S 1317-65-3
7732-18-5
7759-97-6
12001-26-2
111-76-2
14808-60-7
1336-21-6
NU-SAL
FOAM INSULATION ADHESIVE, 118 64742-89-8
8012-95-1
EU-100: HARDENER COMPONENT 26950-63-0
112-24-3
PR-164 CONCRETE PART A 68609-97-2
25068-38-6
LATEX SATIN & GLOSS EXTERIOR FINISHES A-100 107-21-1
112-34-5
14464-46-1
13463-67-7
1314-13-2
LATEX SATIN & GLOSS EXTERIOR FINISHES A-100 13463-67-7
1314-13-2
107-21-1
112-34-5
14464-46-1
LATEX SEMI-GLOSS & GLOSS INTERIOR (SUPP DAT 112-34-5
13463-67-7
LATEX FLAT INTERIOR PROFESSIONAL FINISHES ( 14464-46-1
14807-96-6
471-34-1
13463-67-7
LATEX FLAT INTERIOR PROFESSIONAL FINISHES ( 14808-60-7
14464-46-1
13463-67-7
107-21-1
LATEX FLAT INTERIOR PROFESSIONAL FINISHES ( 14808-60-7
14464-46-1
13463-67-7
107-21-1
LATEX FLAT INTERIOR PROFESSIONAL FINISHES ( 14808-60-7
14464-46-1
13463-67-7
107-21-1
LATEX FLAT INTERIOR PROFESSIONAL FINISHES ( 14808-60-7
14464-46-1
13463-67-7
107-21-1
BROWN WELDABLE PRIMER, X-6541 1330-20-7
108-88-3
8032-32-4
64742-89-8
100-41-4
POXY PRIME CATALYST, DP701 108-88-3
71-36-3
67-63-0
1330-20-7
HEMA-TEK(WRIGHT-GIEMSA) STAIN PAK-BUFFER (S 67-56-1
HEMA-TEK(WRIGHT-GIEMSA) STAIN-PAK RINSE SOL 67-56-1
HEMA-TEK(WRIGHT-GIEMSA) STAIN PAK-STAIN SOL 67-56-1
DMA 4, EPA REG 464-196-39511 94-75-7
LITHIUM CARBONATE 554-13-2
COLD PATCH B (382) 1309-48-4
1344-09-8

Free MSDS Search ( Providing 250,000+ Material Properties )