===================== Product Identification =====================
MSDS NAME:PALGARD EPOXY COATING GLOSS ACTIVATOR
NIIN:00F027714
MSDS Number: BQZXV
=== Responsible Party ===
Company:PRATT AND LAMBERT INC
Address:75 TONAWANDA ST
Box:22
City:BUFFALO
State:NY
ZIP:14240
Country:US
Info Phone Num:716-873-6000
Emergency Phone Num:716-873-6000
CAGE:61196
=== Contractor Identification ===
Company:PRATT & LAMBERT
Box:City:BUFFALO
State:NY
ZIP:14240
Country:US
Phone:716-873-6000
CAGE:77359
Company:PRATT AND LAMBERT INC
Address:Box:6027
City:CLEVELAND
State:OH
ZIP:44101-1027
Country:US
Phone:216-566-2902
CAGE:61196
============= Composition/Information on Ingredients =============
Name:VOL ORGANIC CMPD: 5.3 LB/GAL ( 396 G/L) LESS WATER; 6.1
LB/GAL ( 732 G/L) SOLIDS
RTECS #:9999999VO
Name:WEIGHT PER GALLON IN POUNDS: 8.6
RTECS #:9999999WG
Name:HEXONE, METHYL ISOBUTYL KETONE (MIBK), 4-METHYL-2-PENTANONE
CAS:108-10-1
RTECS #:SA9275000
Fraction by Wt: 10%
Other REC Limits:50 PPM
OSHA PEL:100 PPM/75 STEL
ACGIH TLV:50 PPM/75 STEL; 9293
EPA Rpt Qty:5000 LBS
DOT Rpt Qty:5000 LBS
Name:2-BUTOXYETHANOL (ETHYLENEGLYCOL MONOBUTYL ETHER), BUTYL
CELLOSOLVE, BUTYL GLYCOL, GLYCOL ETHER EB
CAS:111-76-2
RTECS #:KJ8575000
Fraction by Wt: 25%
Other REC Limits:25 PPM (SKIN)
OSHA PEL:S, 50 PPM
ACGIH TLV:S, 25 PPM; 9293
===================== Hazards Identification =====================
Routes of Entry: Inhalation:YES Skin:YES Ingestion:YES
Reports of Carcinogenicity:NTP:NO IARC:NO OSHA:NO
Health Hazards Acute and Chronic:INGESTION: NAUSEA, RED BLOOD CELL,
LIVER & KIDNEY DAMAGE, GASTROINTESTINAL IRRITATION, & VOMITING.
INHALATION: NOSE & THROAT IRRITATION, CENTRAL NERVOUS SYSTEM
DEPRESSION, HEADACHE, DIZZINESS, NAUSEA, & CONFUSION. EYES:
TRANSIENT CORNEAL DAMAGE. SKIN: ABSORPTION IN HARMFUL AMOUNTS,
DEFATTING, & IRRITATION.
Explanation of Carcinogenicity:NONE
Effects of Overexposure:INGESTION: ASPIRATION INTO LUNGS MAY CAUSE
CHEMICAL PNEUMONITIS WHICH CAN BE FATAL. BLOOD, LIVER, & KIDNEY
DAMAGE. INHALATION: PERMANENT BRAIN & NERVOUS SYSTEM DAMAGE. LUNG
DAMAGE. EXPOSURE BY ANY ROU TE MAY CAUSE ERTHROPENIA,
RETICULOCYTOSIS, GRANULOCYTOSIS, LEUKOCYTOSIS, FRAGILITY OF
ERYTHROCYTES & HEMTURIA.
======================= First Aid Measures =======================
First Aid:INHALATION: REMOVE TO FRESH AIR. IF BREATHING STOPS, GIVE
ARTIFICIAL RESPIRATION. KEEP WARM & QUIET. EYES: FLUSH W/WATER,
LIFTING UPPER & LOWER LIDS. CONTINUE FOR 15 MINS. SKIN: WASH W/SOAP
& WATER. I NGESTION: OBTAIN MEDICAL ATTENTION IN ALL CASES. NOTE TO
PHYSICIAN: ETHYLENE GLYCOL MONOBUTYL ETHER IS METABOLIZED TO
BUTOXYACETIC ACID & THIS SUBSTANCE IS EXCRETED IN URINE.
===================== Fire Fighting Measures =====================
Flash Point Method:SCC
Flash Point:96F
Extinguishing Media:CO2, DRY CHEMICAL, ALCOHOL FOAM, POLYMER FOAM
Fire Fighting Procedures:WEAR SELF-CONTAINED BREATHING APPARATUS. WATER
MAY BE INEFFECTIVE, BUT MAY BE USED TO COOL EXPOSED CONTAINERS. IF
WATER IS USED, FOG NOZZLES ARE PREFERABLE.
Unusual Fire/Explosion Hazard:COOL CONTAINERS TO PREVENT PRESSURE
BUILD-UP, POSSIBLE IGNITION, OR EXPLOSION WHEN EXPOSED TO EXTREME
HEAT. FLAMMABLE LIQUID. UN1263.
================== Accidental Release Measures ==================
Spill Release Procedures:WEAR PROTECTIVE EQUIPMENT. KEEP SPECTATORS
AWAY. ELIMINATE IGNITION SOURCES. DIKE & CONTAIN SPILL W/INERT
MATERIAL (SAND OR EARTH). TRANSFER LIQUIDS TO COVERED METAL
CONTAINERS FOR RECOVERY OR DISPOSA L. USE ONLY NON-SPARKING TOOLS.
====================== Handling and Storage ======================
Handling and Storage Precautions:DON'T STORE ABOVE 95F. STORE LARGE
QUANTITIES IN COMPLIANCE W/OSHA. KEEP CONTAINER TIGHTLY CLOSED.
CLOSED AFTER EACH USE.
Other Precautions:DON'T TAKE INTERNALLY. AVOID SKIN CONTACT. EMPTY
CONTAINERS MUST NOT BE WASHED & RE-USED FOR ANY PURPOSE.
GROUND/BOND CONTAINERS TO RECEIVING CONTAINER. DON'T WELD, BRAZE
OR CUT EMPTY CONTAINER. DRUM IS NOT A PRESSURE VESSEL.
============= Exposure Controls/Personal Protection =============
Respiratory Protection:OUTDOORS/OPEN AREAS, USE NIOSH APPROVED
MECHANICAL FILTER RESPIRATOR. RESTRICTED VENTILATION AREAS, USE
NIOSH APPROVED COMBINATION CHEMICAL CARTRIDGE/MECHANICAL FILTER
RESPIRATOR. CONFINED AREA, USE A IR-SUPPLIED RESPIRATOR.
Ventilation:GENERAL DILUTION OR LOCAL EXHAUST IN SUFFICIENT VOLUME &
PATTERN TO MAINTAIN CONCENTRATIONS BELOW TLV EXPOSURE LIMITS
Protective Gloves:SOLVENT IMPERMEABLE
Eye Protection:SAFETY SPECTACLES
Other Protective Equipment:EYEWASH FACILITY, SAFETY SHOWER
Work Hygienic Practices:REMOVE/LAUNDER CONTAMINATED CLOTHING BEFORE
REUSE.
Supplemental Safety and Health
INTENTIONAL MISURE BY DELIBERATELY CONCENTRATING & INHALING THE
CONTENTS MAY BE HARMFUL OR FATAL.
================== Physical/Chemical Properties ==================
Boiling Pt:B.P. Text:237-343F
Vapor Density:>1
Evaporation Rate & Reference:SLOWER THAN ETHER
Percent Volatiles by Volume:45
================= Stability and Reactivity Data =================
Stability Indicator/Materials to Avoid:YES
STRONG ACIDS OR ALKALINE MATERIALS
Stability Condition to Avoid:HEAT, ELECTRICAL EQUIPMENT, SPARKS, FLAME
& OTHER SOURCES OF IGNITION
Hazardous Decomposition Products:CO, CO2, & SMOKE WHEN WELDING OR
CUTTING
==================== Disposal Considerations ====================
Waste Disposal Methods:PREVENT CONTAMINATION OF
SEWERS/STREAMS/GROUNDWATER W/SPILLED MATERIAL OR ABSORBENT.
INCINERATE ONLY IN EPA PERMITTED FACILITY. CONTAMINATED ABSORBANT
MAY BE DISPOSED IN HAZARDOUS WASTE LANDFILL IN AC CORDANCE
W/FEDERAL, STATE, & LOCAL LAWS. D001.
Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.
*** END OF RECORD *** |
|
|