hydrogen peroxide (sara iii). ld50 (90% h*2o*2 water stabilizers supdat:evolution of oxygen upon decomposition. other prec:regulated as a hazardous material when shipped
LD50 LC50 Mixture:SEE INGREDIENT 1.
Routes of Entry: Inhalation:YES Skin:YES Ingestion:YES
Reports of Carcinogenicity:NTP:NO IARC:NO OSHA:NO
Health Hazards Acute and Chronic:EXPOSURE TO SKIN OR EYES MAY CAUSE
CHEMICAL BURNS. INHALATION OF VAPOR OR MIST MAY CAUSE IRRITATION OR
CHEMICAL BURNS TO MUCOUS MEMBRANES & RESPIRATORY SYSTEM. INGESTION
MAY CAUSE CHEMICAL BURNS AS WE LL AS INJURY BY DISTENTION OF THE
ESOPHAGUS OR STOMACH DUE TO THE SUDDEN EVOLUTION OF GASSES.
Explanation of Carcinogenicity:NOT RELEVANT
Effects of Overexposure:SEE HEALTH HAZARDS.
Medical Cond Aggravated by Exposure:NONE SPECIFIED BY MANUFACTURER.
======================= First Aid Measures =======================
First Aid:SKIN:FLUSH W/LG AMTS OF WATER FOR AT LST 15 MINS. QUICKLY
REMOVE CONTAM CLTHG & SHOES. FLUSH CLTHG W/LG AMTS OF WATER.
EYES:FLUSH W/LG AMTS OF WATER FOR AT LST 15 MINS. CONTACT MD IN
CASE OF CONTACT W /PEROXIDE. INGEST:DRINK LG AMTS OF WATER TO
DILUTE. SIT UPRIGHT. CONTACT MD. INHAL:REMOVE VICTIM TO FRESH AIR.
CONTACT MD. NOTE TO MD:IT MAY BE ADVISABLE TO INSERT GASTRIC TUBE
TO RELIEVE/ (SUPDAT)
===================== Fire Fighting Measures =====================
Extinguishing Media:WATER.
Fire Fighting Procedures:WEAR NIOSH/MSHA APPROVED SCBA & FULL
PROTECTIVE EQUIPMENT .
Unusual Fire/Explosion Hazard:STRONG OXIDIZER:HYDROGEN PEROXIDE IS NOT
FLAMM BUT CAN INITIATE SPONT COMBUST OF PAPER, WOOD, CLOTH & OTHER
ORG MATLS. IGNIT MAY BE RAPID, BUT CAN BE (SUPDAT)
Spill Release Procedures:FLUSH SPILL AREA W/LARGE AMOUNTS OF WATER. DO
NOT RETURN SPILLED MATERIAL TO ORIGINAL CONTAINER. COMPLY
W/FEDERAL, STATE & LOCAL REGULATIONS ON REPORTING SPILLS.
Neutralizing Agent:NONE SPECIFIED BY MANUFACTURER.
====================== Handling and Storage ======================
Handling and Storage Precautions:CONSULT MFR ON HNDLG & MATLS OF
CONSTRUCTION. AVOID HEATING HYDROGEN PEROXIDE & STORE AWAY FROM
COMBUSTS. DO NOT CONTAM HYDROGEN PEROXIDE.
Other Precautions:STOR CNTNRS/VESSELS FOR HYDROGEN PEROXIDE MUST BE
VENTED & MADE OF COMPAT PLASTICS, 304 OR 316 STAINLESS STEEL/HIGH
PURITY ALUMINUM. CONT MFR FOR ADDNL INFO REGARDING OTHER COMPAT
MATLS. HYDROGEN PERO XIDE IN CONCS <52% IS NOT (ING 5)
Respiratory Protection:NIOSH/MSHA APPROVED SCBA SHOULD BE AVAILABLE.
Ventilation:NONE SPECIFIED BY MANUFACTURER.
Protective Gloves:RUBBER GLOVES.
Eye Protection:ANSI APPRVD CHEM WORKERS GOGGLES .
Other Protective Equipment:BOOTS, PVC SLICKER SUIT. WATER SOURCE & SFTY
SHOWER/EYE WASH SHLD BE LOCATED CLOSE TO WHERE HYDROGEN PEROXIDE IS
HNDLD.
Work Hygienic Practices:NONE SPECIFIED BY MANUFACTURER.
Supplemental Safety and Health
EXPLO HAZ:DELAYED FOR SEVERAL HRS. RAPID OXYGEN EVOLUTION FROM
DECOMPOSING HYDROGEN PEROXIDE MAY INCR INTENSITY OF FIRE. OXYGEN
ENRICHMENT OF POORLY VENTED ORG ATMS INCRS POTNTL OF VAP PHASE
EXPLOS. M ATLS TO AVOID:PARTICULATE SOLIDS WILL CAUSE DECOMP. FIRST
AID PROC:PVNT INCR PRESS THAT MAY RSLT FROM RAPID (ING 4)
Boiling Pt:B.P. Text:237F,114C
Melt/Freeze Pt:M.P/F.P Text:-61F,-52C
Vapor Pres:18 @ 86F
Spec Gravity:1.195 (H*2O=1)
Evaporation Rate & Reference:<1 (BUTYL ACETATE=1)
Solubility in Water:COMPLETE
Appearance and Odor:CLEAR, COLORLESS LIQUID. CONCENTRATONS >35% MAY
HAVE SHARP ODOR.
Percent Volatiles by Volume:100
================= Stability and Reactivity Data =================
Stability Indicator/Materials to Avoid:YES
CONTAM BY MANY SUBSTANCES INCLUDING HEAVY METALS & THEIR SALTS,
REDUCING AGENTS, STRONG OXIDIZERS, ALKALIES & (SUPDAT)
Stability Condition to Avoid:RATE OF DECOMP INCREASES W/INCREASING TEMP
& MAY BE VERY VIGOROUS W/RAPID GEN OF LG VOLS OF OXYGEN & STEAM.
Hazardous Decomposition Products:OXYGEN, STEAM, PEROXIDE VAPOR & HEAT.
Waste Disposal Methods:DILUTE W/LARGE AMOUNTS OF WATER THEN FLUSH TO
SEWER. COMPLY W/FEDERAL, STATE & LOCAL REGULATIONS.
Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.