LD50 LC50 Mixture:NONE SPECIFIED BY MANUFACTURER.
Routes of Entry: Inhalation:YES Skin:YES Ingestion:NO
Reports of Carcinogenicity:NTP:NO IARC:NO OSHA:NO
Health Hazards Acute and Chronic:ACUTE: INHAL: HDCH, NAUS, IMPAIRMENT
OF RXN TIME & COORD. SKIN: PROLONGED & REPEATED CONTACT MAY CAUSE
IRRITATION. NOTE: TOLUENE & LEAD APPEAR ON NAVY LIST OF OCCUP CHEM
REPROD HAZ. SEEK CONSULTATION FROM APPROP HLTH PROFESSIONALS
CONCERNING LATEST HAZ LIST INFO & SAFE HNDLG & EXPOS INFO. (EFTS OF
OVEREXP)
Explanation of Carcinogenicity:NOT RELEVANT
Effects of Overexposure:HLTH HAZ: ANIMAL STUDIES HAVE CLEARLY
DEMONSTRATED DOSE-RELATED ADVERSE EFTS ON CNS, HEMATOPOIETIC
TISSUE, BLOOD, KIDNEYS & LIVER ASSOC W/ADMIN OF ETHYLENE GLYCOL
MONOBUTYL ETHER (EGBE). (EXTRACTED FR OM DHHS (NIOSH) PUBLICATION
NO: 90-118).
Medical Cond Aggravated by Exposure:NONE SPECIFIED BY MANUFACTURER.
======================= First Aid Measures =======================
First Aid:INHAL: MOVE TO FRESH AIR. SKIN: WASH WITH SOAP AND WATER.
REMOVE SATURATED CLOTHING. EYE: FLUSH WITH WATER FOR AT LEAST 15
MINUTES; CALL A PHYSICIAN. INGEST: CALL MD IMMED .
===================== Fire Fighting Measures =====================
Flash Point Method:CC
Flash Point:20.0F,-6.7C
Lower Limits:SEE INGRED
Extinguishing Media:FOAM, CARBON DIOXIDE, DRY CHEMICAL OR ANY CLASS B
FIRE EXTINGUISHER.
Fire Fighting Procedures:WEAR NIOSH/MSHA APPROVED SCBA AND FULL
PROTECTIVE EQUIPMENT . WATER SPRAY MAY BE INEFTIVE. WATER SHOULD BE
USED TO COOL CONTRS EXPOSED TO FIRE.
Spill Release Procedures:REMOVE ALL SOURCES OF IGNITION, VENTILATE AREA
AND REMOVE WITH INERT ABSORBENT.
Neutralizing Agent:NONE SPECIFIED BY MANUFACTURER.
====================== Handling and Storage ======================
Handling and Storage Precautions:KEEP AWAY FROM HEAT, SPARKS AND OPEN
FLAME. CLOSE CONTAINER AFTER EACH USE. CONSULT NFPA &/OR OSHA
1910.106 FOR ADDNL STORAGE REQUIREMENTS.
Other Precautions:USE APPROVED BONDING AND GROUNDING PROCEDURES.
OBSERVE ALL LABEL PRECAUTIONS.
Respiratory Protection:ADEQUATE VENTILATION IS REQUIRED. IN CONFINED
AREAS, USE NIOSH/MSHA APPROVED RESPIRATOR DEVICE.
Ventilation:PROVIDE SUFFICIENT VENT IN VOL & PATTERN TO KEEP VAP CONC
BELOW GIVEN TLV AND LEL.
Protective Gloves:IMPERVIOUS GLOVES .
Eye Protection:ANSI APPRVD CHEM WORK GOGGLES .
Work Hygienic Practices:NONE SPECIFIED BY MANUFACTURER.
Supplemental Safety and Health
BP: >75.0F,>23.9C.
Waste Disposal Methods:INCINERATE IN APPROVED FACILITY. DO NOT
INCINERATE CLOSED CONTAINERS. DISPOSE I/A/W FEDERAL, STATE AND
LOCAL POLLUTION CONTROL REQUIREMENTS.
Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.