LD50 LC50 Mixture:NONE SPECIFIED BY MANUFACTURER.
Routes of Entry: Inhalation:YES Skin:NO Ingestion:YES
Reports of Carcinogenicity:NTP:NO IARC:NO OSHA:NO
Health Hazards Acute and Chronic:ACUTE:INHAL:MIST OR VAPOR MAY IRRITATE
RESPIRATORY TRACT. INGEST:CAN CAUSE IRRITATION TO MOUTH, THROAT,
ESOPHAGUS & STOMACH. SKIN:CAN CAUSE IRRITATION. EYES:IRRITATING.
CHRONIC:REPEATED SKIN CONTACT M AY CAUSE DERMATITIS.
Explanation of Carcinogenicity:NOT RELEVANT
Effects of Overexposure:SEE HEALTH HAZARDS.
Medical Cond Aggravated by Exposure:NONE SPECIFIED BY MANUFACTURER.
======================= First Aid Measures =======================
First Aid:INHAL:REMOVE PERS FROM CONTAM AREA. IF BRTHG HAS STOPPED,
RESUSCITATE & ADMIN OXYGEN IF AVAIL. SEEK IMMED MED ATTN.
INGEST:NEVER GIVE ANYTHING BY MOUTH TO UNCON PERS, OBTAIN IMMED MED
ATTN. IF VOMIT O CCURS SPONT, KEEP AIRWAY CLEAR. IF SWALLOWED GIVE
LG AMTS OF WATER & INDUCE VOMIT. SEEK IMMED MED ATTN. SKIN:IMMED
WASH CONTAM SKIN W/ PLENTY OF WATER FOR 15 MINS. REMOVE CONTAM
CLTHG & (SUPP DATA)
===================== Fire Fighting Measures =====================
Flash Point:>200F,>93C
Extinguishing Media:WATER FOG OR SPRAY, CARBON DIOXIDE, DRY CHEMICAL,
FOAM.
Fire Fighting Procedures:USE NIOSH/MSHA APPROVED SCBA & FULL PROTECTIVE
EQUIPMENT . KEEP CONTAINERS COOL TO PREVENT RUPTURE & RELEASE OF
MATERIAL.
Unusual Fire/Explosion Hazard:NONE KNOWN
Spill Release Procedures:AVOID CONT W/SKIN, EYES & CLTHG. WEAR PROT
EQUIP (SEE CONTROL MEASURES SECTION). DO NOT BREATHE MIST/VAPS.
CONTAIN SPILL & SOAK UP IN SUITABLE ABSORB. SHOVEL UP INTO
PLASTIC-LINED STEEL CNTNRS. DILUTE RESIDUAL MATL W/COPIOUS AMTS OF
WATER & NEUT.
Neutralizing Agent:NONE SPECIFIED BY MANUFACTURER.
====================== Handling and Storage ======================
Handling and Storage Precautions:STORE IN A COOL DRY PLACE. LOOSEN
COVER CAUTIOUSLY WHEN OPENING.
Other Precautions:NONE SPECIFIED BY MANUFACTURER.
Respiratory Protection:USE NIOSH/MSHA APPROVED RESPIRATOR WHEN AIR
CONCENTRATION IS GREATER THAN TLV OR PEL. USE CARTRIDGE FILTER FOR
ORGANIC VAPORS.
Ventilation:LOCAL EXHAUST RECOMMENDED.
Protective Gloves:NEOPRENE OR NATURAL RUBBER GLOVES.
Eye Protection:SAFETY GLASSES.
Other Protective Equipment:CHEMICALLY RESISTANT COVERALLS, HAT & SHOES
OR BOOTS. EMERGENCY EYE WASH & SAFETY SHOWER SHOULD BE AVAILABLE.
Work Hygienic Practices:WASH THOROUGHLY AFTER HANDLING.
Supplemental Safety and Health
PH:6-6.9(AS IS). FIRST AID PROC:FOOTWEAR. WASH CLTHG BEFORE REUSE.
DISCARD FOOTWEAR IF IT CANNOT BE DECONTAM. SEEK IMMED MED ATTN.
EYES:FLUSH W/PLENTY OF WATER FOR AT LST 15 MINS HOLDING LIDS APART
TO ENSURE FLUSHING OF ENTIRE SURF. WASHING W/IN SEVERAL SECS OF
EXPOS IS ESSNTL TO MIN DMG. SEEK IMMED MED ATTN.
HCC:C3
Boiling Pt:B.P. Text:>212F,>100C
Melt/Freeze Pt:M.P/F.P Text:<32F,<0C
Spec Gravity:1.07 (H2O=1)
pH:SUPDAT
Solubility in Water:COMPLETE
Appearance and Odor:BROWN LIQUID; MUSTY ODOR.
================= Stability and Reactivity Data =================
Stability Indicator/Materials to Avoid:YES
NONE
Stability Condition to Avoid:NONE
Hazardous Decomposition Products:IN A FIRE, OXIDES OF SULFUR & CARBON.
Waste Disposal Methods:DISPOSE OF I/A/W LOCAL, STATE & FEDERAL
REGULATIONS. FOR WASTE DISPOSAL OF OPERATING SOLUTIONS CONSULT
ENTHONE-OMI WASTE DISPOSAL PROCEDURES. FOR MAJOR SPILLS, CONSULT
ENTHONE-OMI FOR DISPOSAL ASSISTA NCE.
Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.