LD50 LC50 Mixture:ORAL LD50 (RAT): 5660 MG/KG (SEE SUPP)
Routes of Entry: Inhalation:YES Skin:NO Ingestion:YES
Reports of Carcinogenicity:NTP:NO IARC:NO OSHA:NO
Health Hazards Acute and Chronic:EYE: IRRITATION. SKIN: PROLONGED OR
REPEATED CONTACT MAY CAUSE IRRITATION/CONTACT DERMATITIS.
INGESTION: HARMFUL. DIPROPYLENE GLYCOL-EYE/NOSE/THROAT IRRITATION.
MORPHOLINE VAPORS-CAN BE CORROSIVE TO N OSE/THROAT/MUCOUS
MEMBRANES. PRODUCT ISA NEPHROTOXIN & HEPATOTOXIN. INHALATION: MAY
CAUSE UNCONSCIOUSNESS.
Explanation of Carcinogenicity:NONE
Effects of Overexposure:INHALATION: VAPORS/MISTS MAY CAUSE
LIGHTHEADEDNESS/DIZZINESS/HEADACHES/UNCONSCIOUSNESS. EYES: REDNESS.
======================= First Aid Measures =======================
Eyes: FLUSH IMMEDIATELY W/LARGE AMOUNTS OF WATER FOR AT LEAST
15 MINS. INHALATION: REMOVE TO FRESH AIR. SKIN: REMOVE CONTAMINATED
CLOTHING. WASH THOROUGHLY W/MILD SOAP & WATER. INGESTION: DO NOT
INDUC E VOMITING. IF CONSCIOUS, DRINK LARGE AMOUNTS OF WATER.
OBTAIN MEDICAL ATTENTION IN ALL CASES.
===================== Fire Fighting Measures =====================
Flash Point Method:TCC
Flash Point:>200F
Extinguishing Media:FOAM, DRY CHEMICAL, CO2, WATER FOG OR SPRAY
Fire Fighting Procedures:DON'T ENTER A FIRE AREA W/OUT PROPER
PROTECTIVE EQUIPMENT, INCLUDING NIOSH/MSHA APPROVED, SCBA. COOL
EXPOSED CONTAINERS W/WATER SPRAY. AVOID VAPORS.
Unusual Fire/Explosion Hazard:NO UNUSUAL FIRE HAZARDS; MATERIAL ISN'T
FLAMMABLE/COMBUSTIBLE.
Spill Release Procedures:WEAR APPROPRIATE PROTECTION. REMOVE IGNITION
SOURCE. APPROACH UPWIND. SHUT OFF LEAK. DIKE/PUMP LARGE SPILL INTO
SALVAGE CONTAINER. SOAK UP RESIDUE/SMALL SPILL W/ABSORBENT
CLAY/SAND/DIRT & PLACE IN SAL VAGE CONTAINER. CONTINUE TO OBSERVE
PRECAUTION.
====================== Handling and Storage ======================
Handling and Storage Precautions:AVOID INHALATION OF VAPORS/MISTS.
AVOID CONTACT W/EYES/SKIN/CLOTHING. KEEP CONTAINER CLOSED WHEN NOT
IN USE. USE W/ADEQUATE VENTILATION.
Other Precautions:STORE IN WELL-VENTILATED AREA. AVOID CONTACT
W/OXIDIZERS. STORE IN COOL, DRY AREA. CONTROL IGNITION SOURCE. KEEP
AWAY FROM HEAT, SPARKS, & OPEN FLAMES.
Respiratory Protection:USE AIR PURIFYING HALF FACE PIECE/CARTRIDGE OR
CANNISTER ACID GAS/ORGANIC VAPOR RESPIRATOR AS NEEDED. A FULL
MEDICAL EVALUATION SHOULD BE PERFORMED DUE TO INDIVIDUAL
SUSCEPTABILITY/SENSITIVITY.
Ventilation:MECHANICAL: IN CONFINED AREA. WHERE ENGINEERING CONTROLS
ARE NOT FEASIBLE, ASSURE NATURAL AIR MOVEMENT.
Protective Gloves:CHEMICAL RESISTANT
Eye Protection:GOGGLES
Work Hygienic Practices:REMOVE/LAUNDER CONTAMINATED CLOTHING BEFORE
REUSE.
Supplemental Safety and Health
LD50 INFORMATION IS ON PROPYLENE GLYCOL MONOMETHYL ETHER.
Waste Disposal Methods:RE-EVALUATE PRODUCT SINCE PRODUCT
USES/TRANSFORMATIONS/MIXTURES/PROCESSES MAY CHANGE THE
CLASSIFICATION TO NON-HAZARDOUS/HAZARDOUS. DISPOSE OF IN ACCORDANCE
W/LOCAL/STATE/FEDERAL REGULATIONS.
Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.