LD50 LC50 Mixture:NONE SPECIFIED BY MANUFACTURER.
Routes of Entry: Inhalation:YES Skin:YES Ingestion:YES
Reports of Carcinogenicity:NTP:NO IARC:NO OSHA:NO
Health Hazards Acute and Chronic:IRRITATION TO THE NOSE AND THROAT,
NAUSEA AND HEADACHE. EYE CONTACT WILL CAUSE LOCAL IRRITATION AND
BURNING SENSATIONS, WITH POSSIBLE EYE DAMAGE.
Explanation of Carcinogenicity:NOT RELEVANT.
Effects of Overexposure:SEE HEALTH HAZARDS.
Medical Cond Aggravated by Exposure:NONE SPECIFIED BY MANUFACTURER.
======================= First Aid Measures =======================
First Aid:EYE:IRRIGATE WITH WATER FOR AT LEAST 15 MINUTES, INCLUDING
UNDER EYELIDS. GET MEDICAL HELP. SKIN:FLUSH WITH WATER.
INHAL:REMOVE TO FRESH AIR. RESTORE AND/OR SUPPORT BREATHING AS
NEEDED. GIVE OXYGEN IF BRTHG IS DFCLT. INGEST:GET PROMPT MED HELP.
GIVE WATER TO DRINK TO DILUTE. IF MEDICAL HELP IS NOT READILY
AVAILABLE, THE AMT INGESTED WAS LARGE AND THE VICTIM IS CONSCIOUS
AND ALERT, INDUCE VOMITING.
===================== Fire Fighting Measures =====================
Flash Point Method:TCC
Flash Point:140F,60C
Extinguishing Media:WATER, DRY CHEMICAL, OR CARBON DIOXIDE CAN BE USED.
Fire Fighting Procedures:USE NIOSH/MSHA APPROVED SCBA & FULL PROTECTIVE
EQUIPMENT .
Unusual Fire/Explosion Hazard:NONE. ANTISTAT IS AN OSHA CLASS III B
LIQUID PRIOR TO APPLICATION TO FABRIC.
Neutralizing Agent:NONE SPECIFIED BY MANUFACTURER.
====================== Handling and Storage ======================
Handling and Storage Precautions:NONE SPECIFIED BY MANUFACTURER.
Other Precautions:PREPLACEMENT AND PERIODIC MEDICAL EXAMINATIONS SHOULD
EMPHASIZE SKIN, SINUSES, AND THE RESPIRATORY SYSTEM.
Respiratory Protection:NIOSH/MSHA APPROVED RESPIRATOR APPROPRIATE FOR
EXPOSURE OF CONCERN .
Ventilation:PROVIDE GENERAL AND EXHAUST VENT (EXPLOSION-PROOF). EXHAUST
SHOULD MAINTAIN A 100CFM FACE VELOCITY.
Protective Gloves:IMPERVIOUS GLOVES .
Eye Protection:ANSI APPRVD CHEM WORKERS GOGGLES .
Other Protective Equipment:ANSI APPRVD EMERGENCY EYE WASH & DELUGE
SHOWER .
Work Hygienic Practices:NONE SPECIFIED BY MANUFACTURER.
Supplemental Safety and Health
NONE SPECIFIED BY MANUFACTURER.
Waste Disposal Methods:BURN WASTE PRODUCT IN AN APPRVD INCINERATOR OR
DISPOSE OF VIA LICENSED WASTE DISPOSAL COMPANY. FOLLOW FEDERAL,
STATE AND LOCAL REGULATIONS.
Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.