LD50 LC50 Mixture:NONE SPECIFIED BY MANUFACTURER.
Routes of Entry: Inhalation:YES Skin:YES Ingestion:YES
Reports of Carcinogenicity:NTP:NO IARC:NO OSHA:NO
Health Hazards Acute and Chronic:SKIN: MAY CAUSE ALLERGIC SKIN REACTION
IN SUSCEPTIBLE INDIVIDUALS. PROLONGED OR REPEATED EXPOSURE MAY
CAUSE SKIN IRRITATION. EYES: MAY BE IRRITATING TO EYES UPON
PROLONGED EXPOSURE. INHALATION: MAY CA USE RESPIRATORY
SENSITIZATION IN SUSCEPTIBLE INDIVIDUALS. IF SPRAYED, EXCESSIVE
CONCS ARE ATTAINABLE (EFTS OF OVEREXP)
Explanation of Carcinogenicity:NOT RELEVANT.
Effects of Overexposure:HEALTH HAZARDS: THAT COULD BE HAZARDOUS ON
SINGLE EXPOSURE. EXCESSIVE EXPOSURE MAY CAUSE IRRITATION OF EYES,
UPPER RESPIRATORY TRACT AND LUNGS. EFFECTS MAY BE DELAYED.
INGESTION: NO HAZARDS ANTICIPATE D FROM INGESTION INCIDENTAL TO
INDUSTRIAL EXPOSURE.
Medical Cond Aggravated by Exposure:NONE SPECIFIED BY MANUFACTURER.
======================= First Aid Measures =======================
First Aid:SKIN: WASH OFF IN FLOWING WATER OR SHOWER. EYES: FLUSH
PROFUSELY WITH FRESH WATER FOR AT LEAST 15 MINUTES AND GET MEDICAL
ATTENTION. INHALATION: MOVE VICTIM TO FRESH AIR AND GIVE ARTIFICIAL
RESPIRATIO N OR OXYGEN IF NEEDED; CALL PHYSICIAN. INGESTION: CALL
MD IMMEDIATELY .
===================== Fire Fighting Measures =====================
Flash Point Method:PMCC
Flash Point:350F,177C
Extinguishing Media:CARBON DIOXIDE,DRY CHEM, FOAM, IF WATER IS USED IT
SHOULD BE IN VERY LRG QTY. RXN BETWEEN WATER & HOT
ISOCYANATE(SUPDAT)
Fire Fighting Procedures:WEAR NIOSH/MSHA APPROVED SCBA AND FULL
PROTECTIVE EQUIPMENT . BURNING WILL PRODUCE TOXIC FUMES.
Unusual Fire/Explosion Hazard:AVOID WATER CONTAMINATION IN CLOSED
CONTAINER. CARBON DIOXIDE EVOLVED.
Spill Release Procedures:VENTILATE AREA; COVER WITH INERT, ABSORBENT
MATERIAL AND REMOVE TO DISPOSAL CONTAINER.
Neutralizing Agent:NONE SPECIFIED BY MANUFACTURER.
====================== Handling and Storage ======================
Handling and Storage Precautions:STORE INDOORS AT 50-95F IN ORIGINAL,
UNOPENED CONTAINERS. PROTECT FROM ATMOSPHERIC MOISTURE. REPLACE
OUTAGE WITH INERT DRY GAS-NITROGEN.
Other Precautions:NONE SPECIFIED BY MANUFACTURER.
Respiratory Protection:ATMOSPHERIC LEVELS SHOULD BE MAINTAINED. WEAR
NIOSH/MSHA APPROVED RESPIRATOR APPROPRIATE FOR EXPOSURE OF CONCERN
.
Ventilation:PROVIDE GENERAL AND/OR LOCAL EXHAUST VENTILATION TO CONTROL
AIRBORNE LEVELS BELOW EXPOSURE GUIDELINES.
Protective Gloves:LATEX RUBBER OR SOLVENT GRADE RUBBER.
Eye Protection:CHEMICAL GOGGLES.
Other Protective Equipment:USE PROT CLTHG IMPERVIOUS TO MATL. SELECTION
OF SPECIFIC ITEMS SUCH AS GLOVES, BOOTS, ETC. WILL DEPEND ON OPER.
(ING 3)
Work Hygienic Practices:NONE SPECIFIED BY MANUFACTURER.
Supplemental Safety and Health
USERS OF "L" VERSION OF HMIS SHOULD CONSULT "LR" VERSION FOR MORE INFO
.BP: 597F,314C DECOMPOSES.EXTING MEDIA: MAY BE VIGOROUS. MATLS TO
AVOID:& HEAT CAN PRDCE ENOUGH PRESS TO RUPTURE CLSD CNTNR . RXN
W/WATER IS SLOW AT TEMPS <49C (<120F), BUT ACCELERATED AT HIGH
TEMPS & IN PRESENCE OF MENTIONED MATLS. SOME(ING 4)
Boiling Pt:B.P. Text:SUPP DATA
Vapor Pres:0.0003@25C
Spec Gravity:1.2 (H*2O=1)
Solubility in Water:REACTS WITH WATER
Appearance and Odor:LIGHT YELLOW LIQUID.
Percent Volatiles by Volume:NIL
================= Stability and Reactivity Data =================
Stability Indicator/Materials to Avoid:YES
WATER,ACID, BASE(ALKALIES, AMMONIA), ALCOHOLS, METAL CMPDS,SURF &
INSOLUBLE UREA. COMBINED EFT OF CARBON DIOXIDE(SUPDAT)
Stability Condition to Avoid:NOT APPLICABLE.
Hazardous Decomposition Products:ISOCYANATE VAPOR AND MIST, CARBON
DIOXIDE, CARBON MONOXIDE, NITROGEN OXIDES AND TRACES OF HYDROGEN
CYANIDE.
Conditions to Avoid Polymerization:MAY OCCUR W/INCOMPAT REACTANTS,
ESPEC STRONG BASES (ALKALIES, TERTIARYAMINES, METAL SALTS), WATER,
OR TEMP >160C (ING 5)
Waste Disposal Methods:FOLLOW ALL FEDERAL, STATE, AND LOCAL
REGULATIONS.
Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.