MSDS   | : | TEFLON, TE3681 | CAS   | : | 116-14-3 9036-19-5 9016-45-9 7732-18-5 3825-26-1 | NAME   | : | ethylene, tetrafluoro-, polymer; octylphenoxy polyethoxy ethanol (surfactant) nonylphenol poly ethoxate; (nonylphenol polyethylene oxide) water octanoic acid, pentadecafluoro-,ammonium salt; (ammonium supp data:at about 400 deg c (750 deg f), with larger efts of overexp:can occur in amts capable of producing efts ing 7:w/discomfort, tearing/blurring of vision. inhal may ing 8:discomfort. ingest may cause gi tract irrit; abnormal ing 9:blood forming sys function w/anemia. individuals ing 10:susceptibility to toxicitiy of excess expos. cmpd is ing 11:following ingest, inhal/skin cntct. animal & human ing 12:blood, and may be detected years after exposure. first aid:for thermal burns. eyes:immed flush eyes w/plenty ing 14:give 2 glasses of water & induce vom. never give waste disp meth:only if incin is capable of scrubbing out ing 16:treatment, stor, transportation, & disposal must be resp prot:fluoride & carbonyl fluoride conc below expos
|
| |
|
|
===================== Product Identification =====================
MSDS NAME:TEFLON, TE3681
NIIN:00N053140
MSDS Number: BVQNS
=== Responsible Party ===
Company:E I DU PONT DE NEMOURS & CO
Address:1007 MARKET STREET
City:WILMINGTON
State:DE
ZIP:19898
Country:US
Info Phone Num:800-441-7515
Emergency Phone Num:800-441-3637;800-424-9300(CHEMTREC)
Preparer's Name:W.H. MARTIN
CAGE:B0589
=== Contractor Identification ===
Company:E I DU PONT DE NEMOURS & CO
Address:RAKETSTRAAT, 100, RUE DE LA FUSEE
City:BRUSSEL
Country:BE
Phone:32-(0)15-401.505
CAGE:B0589
Company:E.I. DUPONT DE NEMOURS & CO
Address:1007 MARKET STREET
Box:City:WILMINGTON
State:DE
ZIP:19898
Country:US
Phone:800-441-7515;800-441-9442
CAGE:18873
============= Composition/Information on Ingredients =============
Name:ETHYLENE, TETRAFLUORO-, POLYMER;
(POLY(TETRAFLUOROETHYLENE))
CAS:116-14-3
RTECS #:KX4025000
Fraction by Wt: 5-62%
OSHA PEL:N/K
ACGIH TLV:N/K
Name:OCTYLPHENOXY POLYETHOXY ETHANOL (SURFACTANT)
CAS:9036-19-5
Fraction by Wt: 0-5%
OSHA PEL:N/K
ACGIH TLV:N/K
Name:NONYLPHENOL POLY ETHOXATE; (NONYLPHENOL POLYETHYLENE OXIDE)
CAS:9016-45-9
RTECS #:MD0900000
Fraction by Wt: 0-5%
OSHA PEL:N/K
ACGIH TLV:N/K
Name:WATER
CAS:7732-18-5
RTECS #:ZC0110000
Fraction by Wt: 33-40%
OSHA PEL:N/K
ACGIH TLV:N/K
Name:OCTANOIC ACID, PENTADECAFLUORO-,AMMONIUM SALT; (AMMONIUM
PERFLUOROOCTANOATE)
CAS:3825-26-1
RTECS #:RH0782000
Fraction by Wt: <0.5%
OSHA PEL:N/K
ACGIH TLV:0.1 MG/M3
Name:SUPP DATA:AT ABOUT 400 DEG C (750 DEG F), WITH LARGER
AMOUNTS AT HIGHER TEMPERATURES.
RTECS #:9999999ZZ
OSHA PEL:N/K
ACGIH TLV:N/K
Name:EFTS OF OVEREXP:CAN OCCUR IN AMTS CAPABLE OF PRODUCING EFTS
OF SYSTEMIC TOXICITY. EYE CNTCT MAY CAUSE EYE IRRIT (ING 8)
RTECS #:9999999ZZ
OSHA PEL:N/K
ACGIH TLV:N/K
Name:ING 7:W/DISCOMFORT, TEARING/BLURRING OF VISION. INHAL MAY
CAUSE IRRIT OF UPPER RESP PASSAGES, W/COUGHING (ING 9)
RTECS #:9999999ZZ
OSHA PEL:N/K
ACGIH TLV:N/K
Name:ING 8:DISCOMFORT. INGEST MAY CAUSE GI TRACT IRRIT; ABNORMAL
LIVER FUNCTION AS DETECTED BY LAB TESTS/ABNORMAL (ING 10)
RTECS #:9999999ZZ
OSHA PEL:N/K
ACGIH TLV:N/K
Name:ING 9:BLOOD FORMING SYS FUNCTION W/ANEMIA. INDIVIDUALS
W/PREEXISTING DISEASES OF LIVER/BONE MARROW MAY HAVE INCR(ING 11)
RTECS #:9999999ZZ
OSHA PEL:N/K
ACGIH TLV:N/K
Name:ING 10:SUSCEPTIBILITY TO TOXICITIY OF EXCESS EXPOS. CMPD IS
ABSORBED BY BODY & MAY BE DETECTED IN BLOOD STREAM (ING 12)
RTECS #:9999999ZZ
Other REC Limits:NONE RECOMMENDED
OSHA PEL:N/K
ACGIH TLV:N/K
Name:ING 11:FOLLOWING INGEST, INHAL/SKIN CNTCT. ANIMAL & HUMAN
EXPERIENCE INDICATE THAT CMPD HAS LONG HALF-LIFE IN (ING 13)
RTECS #:9999999ZZ
OSHA PEL:N/K
ACGIH TLV:N/K
Name:ING 12:BLOOD, AND MAY BE DETECTED YEARS AFTER EXPOSURE.
RTECS #:9999999ZZ
OSHA PEL:N/K
ACGIH TLV:N/K
Name:FIRST AID:FOR THERMAL BURNS. EYES:IMMED FLUSH EYES W/PLENTY
OF WATER FOR AT LEAST 15 MIN. CALL MD. INGEST:IMMED (ING 15)
RTECS #:9999999ZZ
OSHA PEL:N/K
ACGIH TLV:N/K
Name:ING 14:GIVE 2 GLASSES OF WATER & INDUCE VOM. NEVER GIVE
ANYTHING BY MOUTH TO AN UNCONSCIOUS PERSON. CALL MD.
RTECS #:9999999ZZ
OSHA PEL:N/K
ACGIH TLV:N/K
Name:WASTE DISP METH:ONLY IF INCIN IS CAPABLE OF SCRUBBING OUT
HYDROGEN FLUORIDE & OTHER ACIDIC COMBUST PRODS. (ING 17)
RTECS #:9999999ZZ
OSHA PEL:N/K
ACGIH TLV:N/K
Name:ING 16:TREATMENT, STOR, TRANSPORTATION, & DISPOSAL MUST BE
IN ACCORD W/APPLIC FED, STATE/PROVINCIAL, & LOCAL REGS.
RTECS #:9999999ZZ
OSHA PEL:N/K
ACGIH TLV:N/K
Name:RESP PROT:FLUORIDE & CARBONYL FLUORIDE CONC BELOW EXPOS
LIMITS, USE A NIOSH/MSHA APPROVED POS PRESS AIR SUPPLIED RESP.
RTECS #:9999999ZZ
OSHA PEL:N/K
ACGIH TLV:N/K
===================== Hazards Identification =====================
LD50 LC50 Mixture:NONE SPECIFIED BY MANUFACTURER.
Routes of Entry: Inhalation:NO Skin:YES Ingestion:YES
Reports of Carcinogenicity:NTP:NO IARC:NO OSHA:NO
Health Hazards Acute and Chronic:INHAL OF FUMES FROM OVERHEATING
"TEFLON" PTFE MAY CAUSE POLYMER FUME FEVER/TEMP FLU-LIKE ILLNESS
W/FEVER, CHILLS, SOMETIMES COUGH OF APPROX 24HRS DURATION. ING
2&3:SKIN CNTCT MAY CAUSE SKIN IRRIT W/DI SCOMFORT/RASH. EYE CNTCT
MAY CAUSE EYE IRRIT W/DISCOMFORT, TEARING/BLURRING OF VISION. PERM
EYE DAM MAY(EFTS OF OVEREXP)
Explanation of Carcinogenicity:NOT RELEVANT
Effects of Overexposure:HLTH HAZ:OCCUR FROM PRLNGD EXPOS. INHAL MAY
CAUSE UPPER RESP TRACT IRRIT W/COUGHING & DISCOMFORT. INGEST MAY
CAUSE GI IRRIT W/UPPER ABDOMINAL PAIN, "HEART BURN", NASAL, VOM, &
DIARR; HOWEVER, THERE MA Y BE NO SYMPS AT ALL. ING 5:SKIN CNTCT MAY
CAUSE SKIN IRRIT W/DISCOMFORT/RASH. EVIDENCE SUGGESTS SKIN
PERMEATION (ING 7)
Medical Cond Aggravated by Exposure:INDIVIDUALS WITH PREEXISTING
DISEASES OF LUNGS MAY HAVE INCREASED SUSCEPTIBILITY TO TOXICITY OF
EXCESSIVE EXPOSURE FROM THERMAL DECOMPOSITION PRODUCTS.
======================= First Aid Measures =======================
First Aid:INHAL:NO SPEC INTERVENTION IS INDICATED AS CMPD IS NOT LIKELY
TO BE HAZ BY INHAL. CONSULT MD IF NECESSARY. IF EXPOSED TO FUMES
FROM OVERHEATING/COMBUST, MOVE TO FRESH AIR. CONSULT MD IF SYMPS
PERSIST. SKIN:FLUSH SKIN W/WATER AFTER CONTACT.WASH CONTAM CLTHG
BEFORE REUSE. IF MOLTEN MATL GETS ON SKIN, COOL RAPIDLY W/COLD
WATER. DO NOT ATTEMPT TO REMOVE MATL FROM SKIN. OBTAIN MED
TREATMENT (ING 14)
===================== Fire Fighting Measures =====================
Flash Point Method:OC
Flash Point:DOES NOT FLASH
Extinguishing Media:WATER, FOAM, DRY CHEMICAL, CO*2
Fire Fighting Procedures:WEAR NIOSH/MSHA APPROVED SCBA AND FULL
PROTECTIVE EQUIPMENT .
Unusual Fire/Explosion Hazard:DOES NOT BURN W/OUT AN EXTERNAL FLAME.
PROT FROM HYDROGEN FLUORIDE FUMES WHICH REACT W/WATER TO FORM
HYDROFLURIC ACID. WEAR NEOPRENE GLOVES WHEN (SUPP DATA)
================== Accidental Release Measures ==================
Spill Release Procedures:SOAK UP WITH SAWDUST, SAND, OIL DRY OR OTHER
ABSORBENT MATERIAL. SHOVEL OR SWEEP UP.
Neutralizing Agent:NONE SPECIFIED BY MANUFACTURER.
====================== Handling and Storage ======================
Handling and Storage Precautions:KEEP CONTAINERS CLOSED TO AVOID
CONTAMINATION. AVOID FREEZING TEMPS. TEMPS BETWEEN 60 AND 80
DEGREES (16 TO 27 DEG C) RECOMMENDED.
Other Precautions:AVOID CONTAMINATION OF CIGARETTES OR TOBACCO.
============= Exposure Controls/Personal Protection =============
Respiratory Protection:AT PROCESSING TEMPS LESS THAN 400 DEG C (750 DEG
F) NIOSH/MSHA APPRVD AIR PURIFYING RESP W/HIGH EFFICIENCY DUST/MIST
CARTRIDGE/CANISTER. FOR PROCESSING TEMPS ABOVE 400 DEG C (750 DEG
F), IF VENT IS IN ADEQ TO MAINTAIN HYDROGEN (ING 18)
Ventilation:USE LOCAL EXHAUST TO COMPLETELY REMOVE VAPORS AND FUMES
LIBERATED DURING HOT PROCESSING FROM THE WORK AREA.
Protective Gloves:IMPERVIOUS GLOVES
Eye Protection:CHEMICAL SPLASH GOGGLES AND FACESHIELD.
Other Protective Equipment:WEAR IMPERVIOUS APRON, BOOTS OR WHOLE
BODYSUIT MADE FROM NEOPRENE, AS APPROP TO AVOID SKIN CONTACT.
Work Hygienic Practices:NONE SPECIFIED BY MANUFACTURER.
Supplemental Safety and Health
SOL IN H*2O:SOLIDS INSOL; DISPERSION MAY BE DILUTED. EXPLO HAZ:HNDLG
REFUSE FROM FIRE INVOLVING "TEFLON". MATLS TO AVOID:FLUORINE (F*2)
& RELATED CMPDS (E.G., CHLORINE TRIFLUORIDE, CLF*3). CNTCT W/INC
OMPATIBLES CAN CAUSE FIRE/AN EXPLO. HAZDECOMP:TRACE AMTS OF
HYDROGEN FLUORIDE & CARBONYL FLUORIDE MAY BE EVOLVED(ING 6)
================== Physical/Chemical Properties ==================
Spec Gravity:2.1-2.3
pH:10
Solubility in Water:SUPP DATA
Appearance and Odor:MILKY LIQUID, SLIGHT AMMONIA ODOR.
Percent Volatiles by Volume:33-40
================= Stability and Reactivity Data =================
Stability Indicator/Materials to Avoid:YES
INCOMPATIBLE/CAN REACT W/FINELY DIVIDED METAL POWDERS (E.G., ALUMINUM &
MAGNESIUM) & POTENT OXIDIZERS LIKE (SUPP DATA)
Stability Condition to Avoid:STABLE AT NORMAL TEMPERATURES AND STORAGE
CONDITIONS.
Hazardous Decomposition Products:HEATING ABOVE 300 C (572 DEG F) MAY
CAUSE EVOLUTION OF PARTICULATE MATTER, WHICH CAN CAUSE POLYMER FUME
FEVER (SUP DAT)
==================== Disposal Considerations ====================
Waste Disposal Methods:(1)SEPARATE SOLIDS FROM LIQ BY PRECIPITATION &
DECANTING/FILTERING. DISP OF DRY SOLIDS IN LANDFILL THAT IS
PERMITTED, LICENSED/REGISTERED BY STATE TO MANAGE INDUSTRIAL SOLID
WASTE. DISCHARGE LIQ FILTR ATE TO WASTEWATER TREATMENT SYS.
(2)INCIN (ING 16)
Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.
*** END OF RECORD *** |
|
|
ALL PAGES On Chemical Property IN THIS GROUP
| NAME | CAS |
16-20-0 MONO AMMONIUM PHOSPHATE SULFATE
| |
JIT DOA
| 103-23-1 |
1223, GREEN UNIKLEEN HD DEGREASER PART CLEANER
| 1344-09-8 27176-87-0 26027-38-3 7732-18-5 7320-34-5 1330-72-7 |
DIFLUOROETHANE
| 75-37-6 |
LS-1878
| 1317-33-5 |
EPOXY CONDUCTIVE COATING PART A, 3525
| 25068-38-6 1330-20-7 |
EPOXY CONDUCTIVE COATING PART B, 3525
| 1323-65-5 13463-67-7 1330-20-7 50-00-0 |
INK FLUSH 1F100
| 7664-41-7 111-76-2 |
W/B ACRYLIC EN GOLD METALLIC, 728H059
| 111-76-2 112-34-5 85-68-7 1863-63-4 1336-21-6 124-68-5 111-77-3 1333-86-4 |
AROCHLOR 1262, F293
| 37324-23-5 |
AROCHLOR 1221 100 UG/ML IN METHANOL, F108S
| 11104-28-2 67-56-1 |
AROCHLOR 1242, F109
| 53469-21-9 |
HYDRITE R
| 1332-58-7 7732-18-5 |
LIGHTHOUSE WHITE MAGIC 100-1
| |
ML LUBRICANT, 0047
| 8052-42-4 64742-56-0 64742-62-7 71-55-6 64742-52-5 64742-53-6 75-28-5 74-98-6 106-97-8 |
SKYSOL 200, FS200
| 64742-48-9 5989-27-5 |
SS #510 CLEAR ROLL/BRUSH ADHESIVE
| 64742-48-9 108-88-3 107-21-1 |
FERRIC AMMONIUM CITRATE, GREEN, 1977
| 1185-57-5 |
HYSTER HCE-50 YELLOW GLOSS ENAMEL
| 8032-32-4 108-88-3 1330-20-7 |
STYLE 5300 (GTP)
| 7782-42-5 7787-37-3 7631-95-0 |
PRODUCT 1800
| 7782-42-5 1313-27-5 |
ALUME-E, 1062
| 7664-39-3 7664-38-2 7664-93-9 111-76-2 9016-45-9 |
COOPERKNIT
| 7631-86-9 |
SANDTEX HIGH TEMPERATURE TEXTILES
| 7631-86-9 1310-73-2 409-21-2 |
PRO-LINE 401-WHITE AND COLORS ENAMEL
| 66070-93-7 8032-32-4 1330-20-7 108-88-3 110-43-0 68152-81-8 13463-67-7 1317-65-3 71-55-6 64742-88-7 |
PRO-LINE 400-PRO-VINYL WHITE AND COLORS
| 7732-18-5 9003-01-4 1336-21-6 67-63-0 57-55-6 25265-77-4 13463-67-7 1336-21-6 7732-18-5 50-00-0 108-05-4 |
NITROGEN DIOXIDE
| 10102-44-0 |
ZINC ACETATE
| 5970-45-6 |
SUPER AGITENE 141
| 64742-47-8 34590-94-8 |
SURE BET PLUS 309
| 7732-18-5 7664-38-2 77-92-9 112-34-5 11138-66-2 127087-87-0 57-55-6 5197-80-8 |
BLACK ENDORSER
| 57-55-6 |
SENTRY LATEX SG ACCENT BASE, 800-217
| 25265-77-4 |
ADDITIVE FOR COOLING FLUID
| 111-42-2 |
TEFLON, B
| 116-14-3 9036-19-5 9016-45-9 7732-18-5 3825-26-1 |
TEFLON, 30
| 116-14-3 9036-19-5 9016-45-9 7732-18-5 3825-26-1 |
TEFLON, 30B
| 116-14-3 9036-19-5 9016-45-9 7732-18-5 3825-26-1 |
TEFLON, 30N
| 116-14-3 9036-19-5 9016-45-9 7732-18-5 3825-26-1 |
TEFLON, G108
| 116-14-3 9036-19-5 9016-45-9 7732-18-5 3825-26-1 |
TEFLON, G550
| 116-14-3 9036-19-5 9016-45-9 7732-18-5 3825-26-1 |
TEFLON, TE3170
| 116-14-3 9036-19-5 9016-45-9 7732-18-5 3825-26-1 |
TEFLON, TE3313
| 116-14-3 9036-19-5 9016-45-9 7732-18-5 3825-26-1 |
TEFLON, TE3417
| 116-14-3 9036-19-5 9016-45-9 7732-18-5 3825-26-1 |
TEFLON, TE3500
| 116-14-3 9036-19-5 9016-45-9 7732-18-5 3825-26-1 |
TEFLON, TE3584
| 116-14-3 9036-19-5 9016-45-9 7732-18-5 3825-26-1 |
TEFLON, TE3620
| 116-14-3 9036-19-5 9016-45-9 7732-18-5 3825-26-1 |
TEFLON, TE3631
| 116-14-3 9036-19-5 9016-45-9 7732-18-5 3825-26-1 |
TEFLON, TE3633
| 116-14-3 9036-19-5 9016-45-9 7732-18-5 3825-26-1 |
TEFLON, TE3681
| 116-14-3 9036-19-5 9016-45-9 7732-18-5 3825-26-1 |
TEFLON, TE3684
| 116-14-3 9036-19-5 9016-45-9 7732-18-5 3825-26-1 |
TEFLON, TE3685
| 116-14-3 9036-19-5 9016-45-9 7732-18-5 3825-26-1 |
|
|