Search   
MSDS  : RPA509 CAMP 125I ASSAY SYSTEM B
CAS  : 121-44-8
108-24-7
NAME  : triethylamine
acetic anhydride
===================== Product Identification =====================

MSDS NAME:RPA509 CAMP 125I ASSAY SYSTEM B
NIIN:00F037589
MSDS Number: BWJLF
=== Responsible Party ===
Company:AMERSHAM HOLDINGS INC
Address:2636 S CLEARBROOK DR
City:ARLINGTON HEIGHTS
State:IL
ZIP:60005-4692
Country:US
Info Phone Num:708-593-6300/800-323-9750
Emergency Phone Num:708-593-6300/800-323-9750
CAGE:GO371
=== Contractor Identification ===
Company:AMERSHAM CORP
Address:2636 S. CLEARBROOK DRIVE
Box:City:ARLINGTON HEIGHTS
State:IL
ZIP:60005-4692
Country:US
Phone:800-323-9750
CAGE:51431
Company:AMERSHAM HOLDINGS INC
Address:2636 S CLEARBROOK DR
City:ARLINGTON HEIGHTS
State:IL
ZIP:60005-4692
Country:US
Phone:708-593-6300/800-323-9750
CAGE:GO371

============= Composition/Information on Ingredients =============

Name:TRIETHYLAMINE
CAS:121-44-8
RTECS #:YE0175000
Fraction by Wt: >1%
Other REC Limits:10 PPM
OSHA PEL:100 MG/CUM
ACGIH TLV:10 PPM
EPA Rpt Qty:5000 LBS
DOT Rpt Qty:5000 LBS

Name:ACETIC ANHYDRIDE
CAS:108-24-7
RTECS #:AK1925000
Fraction by Wt: >1%
OSHA PEL:20 MG/CUM
ACGIH TLV:5 PPM
EPA Rpt Qty:5000 LBS
DOT Rpt Qty:5000 LBS

===================== Hazards Identification =====================

LD50 LC50 Mixture:ORAL LD50 (RATS): 460MG/KG TRIETHYLAMINE
Routes of Entry: Inhalation:YES Skin:NO Ingestion:YES
Reports of Carcinogenicity:NTP:NO IARC:NO OSHA:NO
Health Hazards Acute and Chronic:INHALATION/INGESTION: LIVER INJURY MAY
OCCUR. MAY AFFECT THE NERVOUS SYSTEM. SKIN: DERMATITIS.
Explanation of Carcinogenicity:NONE
Effects of Overexposure:REDNESS, PAIN, HEADACHE, NAUSEA, DIZZINESS,
SORE THROAT, ABDOMINAL PAIN.

======================= First Aid Measures =======================

First Aid:SKIN/EYES: WASH W/COPIOUS AMOUNTS OF WATER FOR 15 MINS.
INHALATION: REMOVE TO FRESH AIR. INGESTION: RINSE MOUTH. DON'T
INDUCE VOMITING, GIVE COPIOUS AMOUNTS OF WATER TO DRINK. OBTAIN
MEDICAL ATTENTION IN ALL CASES.

===================== Fire Fighting Measures =====================

Flash Point Method:CC
Flash Point:17F
Extinguishing Media:CO2, DRY CHEMICAL, FOAM, HALONS
Unusual Fire/Explosion Hazard:EXPLOSIVE AIR MIXTURE MAY BE FORMED >
ROOM TEMP. VAPOR IS > THAN AIR & MAY TRAVEL ALONG THE
GROUND/DISTANT IGNITION IS POSSIBLE.

================== Accidental Release Measures ==================

Spill Release Procedures:IF MIXED W/RADIOACTIVE MATERIAL TREAT AS
RADIOACTIVE. IF NOT, WIPE AREA W/ABSORBENT MATERIAL, MAKING SURE NO
CONTACT W/INDIVIDUAL. WASH AREA W/SOAP & WATER.

====================== Handling and Storage ======================

Handling and Storage Precautions:KEEP CONTAINERS TIGHTLY SEALED. STORE
IN A COOL, DRY PLACE AWAY FROM IGNITION SOURCES.
Other Precautions:AVOID CONTACT W/EYES, SKIN/CLOTHING. AVOID BREATHING
VAPORS/DUST.

============= Exposure Controls/Personal Protection =============

Respiratory Protection:NOT NORMALLY REQUIRED FOR ROUTINE USE IF PROPER
VENTILATION IS USED.
Ventilation:LOCAL & MECHANICAL EXHAUST.
Protective Gloves:NITRILE, NEOPRENE
Eye Protection:SAFETY GLASSES/GOGGLES
Other Protective Equipment:LAB COAT
Work Hygienic Practices:REMOVE/LAUNDER CONTAMINATED CLOTHING BEFORE
REUSE. WASH THOROUGHLY AFTER HANDLING.
Supplemental Safety and Health

================== Physical/Chemical Properties ==================

Boiling Pt:B.P. Text:193F
Vapor Pres:54
Vapor Density:3.5
Spec Gravity:0.7
Solubility in Water:COMPLETE
Appearance and Odor:COLORLESS LIQUID W/CHARACTERISTIC ODOR

================= Stability and Reactivity Data =================

Stability Indicator/Materials to Avoid:YES
STRONG ACIDS, OXIDIZING AGENTS.
Stability Condition to Avoid:HEAT, SPARKS, IGNITION SOURCES & OPEN
FLAMES.
Hazardous Decomposition Products:CORROSIVE FUMES

==================== Disposal Considerations ====================

Waste Disposal Methods:DISPOSE OF IAW/FEDERAL, STATE & LOCAL
REGULATIONS.

Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.

*** END OF RECORD ***
Search More   
ALL PAGES On Chemical Property IN THIS GROUP
NAMECAS
O-763 (1,1-DIMETHYLETHYL)BENZENE 98-06-6
O-639 1,3-DICHLOROPROPANE 142-28-9
F2224S ACIFLUORFEN METHYL ESTER 1000UG/ML ACETONE:ISOOCTANE 67-64-1
540-81-1
F2244S BENTAZON METHYL DERIVATIVE 67-64-1
540-81-1
LUNG DIFFUSION MIX 630-08-0
7440-59-7
7727-37-9
7782-44-7
GASEOUS CARBON DIOXIDE 124-38-9
943-630 S 43216 ELECTROLYTE SOLUTION FOR P02 ELECTRODE 7447-40-7
9007-35-6
89-83-8
7732-18-5
7558-79-4
7778-77-0
ONYX TM FOUNTAIN CONCENTRATE II 7732-18-5
112926-00-8
7631-99-4
68-04-2
7757-82-6
7664-38-2
67-63-0
943-660 S 2030 QUALICHECK BLOOD GAS ACIDEMIA 55965-84-9
7558-79-4
144-55-8
7558-80-7
7778-77-0
7732-18-5
943-661 S 2040 QUALICHECK BLOOD GAS NORMAL 7732-18-5
55965-84-9
7558-79-4
144-55-8
7558-80-7
7778-77-0
943-662 S 2050 QUALICHECK BLOOD GAS AKALEMIA 55965-84-9
7558-79-4
144-55-8
7558-80-7
7778-77-0
7732-18-5
943-628 S 4306 RINSE SOLUTION 55965-84-9
7647-14-5
144-55-8
7732-18-5
CEMENTED TUNGSTEN CARBIDE & HIGH-SPEED STEEL CUTTING TOOLS 7440-02-0
7440-21-3
7440-25-7
7440-33-7
12070-12-1
1314-62-1
11130-21-5
7440-44-0
1333-86-4
7440-47-3
12012-35-0
7440-48-4
7440-50-8
1309-37-1
7439-96-5
7439-98-7
S-16 SEALER 108-88-3
110-19-0
64-17-5
67-63-0
110-43-0
POR-15 SOLVENT 95-63-6
1330-20-7
98-82-8
100-41-4
64742-95-6
NLDB NRP SPRAY LEAK DETECTOR 12627-37-1
102-71-6
107-21-1
ZURN NEO-SEAL GASKET CEMENT (3/4 OZ SINGLE USE TUBE) 1309-48-4
7440-66-6
1333-86-4
108-88-3
78-93-3
67-64-1
TOXI-TUBES A 142-82-5
67-63-0
107-06-2
75-09-2
TOXI-TUBES B 142-82-5
75-09-2
7646-85-7
GF 1210 SERIES FLUXES 8050-09-7
67-63-0
78-83-1
64741-65-7
GF 1215 SERIES FLUXES 8050-09-7
67-63-0
78-83-1
64741-65-7
GF 1230 SERIES FLUXES 8050-09-7
67-63-0
78-83-1
64741-65-7
GF 1240 SERIES FLUXES 78-83-1
64741-65-7
8050-09-7
67-63-0
GF 1250 SERIES FLUXES 8050-09-7
67-63-0
78-83-1
64741-65-7
METAL-READY RUST REMOVER & PREPRIMER 7732-18-5
7664-38-2
7779-90-0
9036-19-5
SHOFU BROWNIE/GREENIE/SUPERGREENIE POINTS/WHEELS/FLOPPY DISK
5 MINUTE EPOXY GEL RESIN 25068-38-6
5 MINUTE EPOXY GEL HARDENER 90-72-2
R-0683 HARDNESS REAGENT 60-00-4
1310-73-2
7786-30-3
7732-18-5
SUPER STURDY II ROOF COATING 64742-94-5
8052-42-4
8032-32-4
0082669 UNOPETTE BRAND TEST 5836/5838/5850/5851 7647-14-5
26628-22-8
0316192 HEMASPARY/REAGENT D/FIXATIVE 67-56-1
ATCC CULTURE 67-68-5
LB 1604 LOW ODOR HIGH HIDE WH DRY MIST L/F 64741-65-7
142-82-5
64741-41-9
8R4077 XEROX FUSER SHIELD 63148-62-9
99363-37-8
0426756 GROUP A STREMTOCOCCUS ANTIBODY
0426756 GROUP B STREPTOCOCCUS ANTIBODY
0426756 GROUP C STREPTOCOCCUS ANTIBODY
0426756 GROUP F STREPTOCOCCUS ANTIBODY
0426756 GROUP G STREPTOCOCCUS ANTIBODY
0426756 POLYVALENT POSITIVE CONTROL
0103 ZEP AEROLUBE NC 8032-32-4
75-28-5
74-98-6
106-97-8
A00344 344 GREEN CORR/INHIB/PRIMER 75-28-5
108-88-3
1330-20-7
71-36-3
67-64-1
14807-96-6
471-34-1
74-98-6
TRK673 108-88-3
64-17-5
RPA509 CAMP 125I ASSAY SYSTEM B 121-44-8
108-24-7
0672958 21731, 21732 MOELLER DECARBOXYLASE BROTH BASE 5 ML
S4013 STRONTIUM ATOMIC ABSORPTION STANDARD SOLUTION 7440-24-6
7647-01-0
0748188 4331628/4331629 AMOXICILLIN W/CLAVULANIC ACID 26787-78-0
58001-44-8
SULFURIC ACID SOLUTION N/50 0.500N 7664-93-9
138 HARDNESS BUFFER SOLUTION ODORLESS 102-71-6

Free MSDS Search ( Providing 250,000+ Material Properties )