LD50 LC50 Mixture:ORAL LD50 (RAT): 80 MG/KG (SUPP)
Routes of Entry: Inhalation:YES Skin:YES Ingestion:YES
Reports of Carcinogenicity:NTP:NO IARC:NO OSHA:NO
Health Hazards Acute and Chronic:EYES: MAY CAUSE BURNS. SKIN: MAY CAUSE
CAUSTIC BURNS. INGESTION: POSSIBLE GAS EMBOLISM, CORROSIVE TO
DIGESTIVE TRACT. INHALATION: RESPIRATORY TRACT IRRITATION.
Explanation of Carcinogenicity:NONE
Effects of Overexposure:EYES: MAY CAUSE BURNS. SKIN: MAY CAUSE CAUSTIC
BURNS. INGESTION: POSSIBLE GAS EMBOLISM, CORROSIVE TO DIGESTIVE
TRACT. INHALATION: RESPIRATORY TRACT IRRITATION.
======================= First Aid Measures =======================
Eyes: FLUSH W/WATER FOR 15 MINS. SKIN: WASH AFFECTED AREA
W/SOAP & WATER. INHALATION: REMOVE TO FRESH AIR. INGESTION: IF
ALERT, DRINK SEVERAL GLASSES OF WATER. INDUCE VOMITING & TRANSFER
TO A HOSPITAL . IF NOT ALERT, TRANSFER TO HOSPITAL IMMEDIATELY &
DON'T INDUCE VOMITING. OBTAIN MEDICAL ATTENTION IN ALL CASES.
===================== Fire Fighting Measures =====================
Extinguishing Media:DRY CHEMICAL, POWDER. DON'T USE WATER.
Fire Fighting Procedures:DON'T USE WET CHEMICAL, WATER/CO2
EXTINGUISHERS.
Unusual Fire/Explosion Hazard:FLAMMABLE SOLID. MIXTURE OF HYDROGEN GAS
W/OXYGEN/AIR IN A CONFINED AREA WILL EXPLODE IF IGNITED BY A SPARK,
FLAME/OTHER IGNITION SOURCE. (SEE SUPP)
Spill Release Procedures:SWEEP UP PELLETS FOR PROPER DISPOSAL.
====================== Handling and Storage ======================
Handling and Storage Precautions:ALL USUAL PRECAUTIONS ATTENDANT TO
HANDLING HYDROGEN GAS SHOULD BE OBSERVED WHEN EMPLOYING GASPAK PLUS
HYDROGEN/CARBON DIOXIDE GENERATOR ENVELOPES.
Respiratory Protection:NONE REQUIRED UNDER NORAML PRODUCT USAGE.
Ventilation:GENERAL & LOCAL TO MEET TLV REQUIREMENTS.
Protective Gloves:NONE REQUIRED UNDER NORMAL USAGE.
Eye Protection:SAFETY GLASSES.
Other Protective Equipment:EYEWASH STATION.
Supplemental Safety and Health
SOLUBILITY IN WATER: ENVELOPE DESIGNED TO HOLD 10 ML OF WATER. UNUSUAL
FIRE HAZARDS CONT"D: SODIUM BOROHYDRIDE IS WATER-REACTIVE METAL
HYDRIDE IN THIS PRODUCT & CONSTITUTES 92.5% OF DARKER PELLET. ORA L
LD50 CONT'D: INFORMATION IS FOR COBALT CHLORIDE, ANHYDROUUS.
Waste Disposal Methods:DISPOSE OF IAW/FEDERAL, STATE, LOCAL & EPA
REGULATIONS.
Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their