LD50 LC50 Mixture:NONE SPECIFIED BY MANUFACTURER.
Routes of Entry: Inhalation:YES Skin:YES Ingestion:YES
Reports of Carcinogenicity:NTP:NO IARC:NO OSHA:NO
Health Hazards Acute and Chronic:INHAL:ALTHOUGH NOT REPORTED, VAPOR
MIGHT CAUSE LIPOID PNEUMONITIS IF HIGH CONCENTRATIONS ARE ASPIRATED
INTO LUNGS. INGEST:LOW ORAL TOXICITY. ALTHOUGH NOT REPORTED,
IRRITATION OF NASAL & PHARYNGEAL MUC OUS MIGHT FOLLOW DIRECT
EXPOSURE TO PRODUCT. SKIN:PROLONGED OR REPEATED CONTACT CAN CAUSE
IRRITATION, (EFTS OF OVEREXP)
Explanation of Carcinogenicity:NOT RELEVANT
Effects of Overexposure:HLTH HAZ:DEFATTING OF SKIN & DERMATITIS.
EYES:LIQUID CAN CAUSE SLIGHT TEMPORARY IRRITATION W/SLIGHT
TRANSIENT CORNEA INJURY. VAPORS CAN IRRITATE. BASED ON AVAILABLE
DATA, REPEATED EXPOSURES ARE NOT AN TICIPATED TO CAUSE ANY
SIGNIFICANT ADVERSE EFFECTS.
Medical Cond Aggravated by Exposure:NONE SPECIFIED BY MANUFACTURER.
======================= First Aid Measures =======================
First Aid:INHAL:REMOVE TO FRESH AIR. DO NOT GIVE EPINEPHRINE. GIVE
ARTIFICIAL RESPIRATION IF NECESSARY. CALL MD. EYES:FLUSH W/WATER
FOR AT LEAST 15 MINUTES; IF IRRITATION PERSISTS CALL MD. SKIN:FLUSH
W/WATER FO R 15 MINUTES; IF IRRITATION PERSISTS CALL MD. INGEST:DO
NOT INDUCE VOMITING. CONTACT MD IMMEDIATELY.
===================== Fire Fighting Measures =====================
Flash Point Method:COC
Flash Point:145F,63C
Lower Limits:0.7%
Upper Limits:6%
Extinguishing Media:WATER, FOAM, DRY CHEMICAL, CARBON DIOXIDE.
Fire Fighting Procedures:USE NIOSH/MSHA APPROVED SCBA & FULL PROTECTIVE
EQUIPMENT . KEEP CONTAINERS COOL W/WATER SPRAY.
Unusual Fire/Explosion Hazard:CNTNRS MAY POSS GENERATE PRESS WHEN
HEATED CAUSING VIOLENT BURSTING OF CNTNR. KEEP LIQ AWAY FROM OPEN
FLAME. FORMS TOX DECOMP PRODS. RAGS SOAKED W/ (SUPDAT)
Spill Release Procedures:ALTHOUGH SPILL/LG RELS IS UNLIKELY TO OCCUR IN
MARKER-TYPE CNTNR, IN EVENT OF SUCH OCCUR, EVACUATE AREA, ABSORB
SPILLED LIQ W/COMMERCIAL NON-FLAMM ABSORB, I.E., SAND, VERMICULITE.
REMOVE UNPROT PERS. PROT PERS SHOULD REMOVE IGNIT SOURCES
&(SUPDAT)
Neutralizing Agent:NONE SPECIFIED BY MANUFACTURER.
====================== Handling and Storage ======================
Handling and Storage Precautions:PRLNG CONT W/SKIN WILL CAUSE IRRIT &
POSS DERM. DO NOT ALLOW PRLNG DIRECT SOLV CONT W/SKIN. AVOID BRTHG
VAPS.
Other Precautions:AVOID LIGHTED CIGARETTES, FLAME, WELDING/HOT SPOTS
WHICH COULD PROMOTE COMBUST & MAY GENERATE TOXIC DECOMP PRODS.
STORE CONTAINERS IN A COOL, DRY PLACE.
Respiratory Protection:NIOSH/MSHA APPROVED RESPIRATOR APPROPRIATE FOR
EXPOSURE OF CONCERN . NONE REQUIRED IN VENTILATED WORK AREAS.
Ventilation:ADEQUATE VENTILATION. LOCAL EXHAUST:FOR SMALL WORK AREAS.
MECHANICAL:ADEQUATE FOR STORAGE.
Protective Gloves:USE VINYL OR VITON GLOVES ,(ING 2)
Eye Protection:ANSI APPROVED CHEM WORKERS GOGGS .
Other Protective Equipment:EYE WASH FOUNTAIN & DELUGE SHOWER WHICH MEET
ANSI DESIGN CRITERIA . PROT CLTHG FOR RPTD CONT. PVA/NEOPRENE PREF.
Work Hygienic Practices:REMOVE CLOTHING & RINSE CLEAN W/WATER IF
BECOMES SOAKED W/SOLVENT.
Supplemental Safety and Health
EXPLO HAZ:CLEANER FROM PROD CAN POSS BE IGNITED THRU SPONT COMBUST.
STORE/DISP OF RAGS ONLY IN APPRVD FIRE SUPPRESSING CNTNRS. SPILL
PROC:SHUT OFF FIRE SOURCES. PROVIDE VENT. USING SPK-PROOF SHOVEL, P
LACE ABSORB MATL INTO DRUMS & CLOSE. IFCLEAN-UP DELAYED, DILUTE
W/WATER FIRST TO REDUCE FIRE HAZ & ABSORB.
================= Stability and Reactivity Data =================
Stability Indicator/Materials to Avoid:YES
STRONG ALKALIES, STRONG OXIDIZERS & OTHER REACTIVE METALS.
Stability Condition to Avoid:AVOID OPEN FLAME WHICH CAN CAUSE IGNITION.
Hazardous Decomposition Products:CARBON MONOXIDE, CARBON DIOXIDE.
Waste Disposal Methods:COMPLY W/FEDERAL, STATE & LOCAL REGULATIONS.
CONSULT APPROPRIATE REGULATORY AGENCY PRIOR TO DISPOSAL OR
DISCHARGE OF WASTE MATERIAL.
Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.