LD50 LC50 Mixture:LD50:(ORAL,RAT) 4400 MG/KG.
Routes of Entry: Inhalation:YES Skin:YES Ingestion:NO
Reports of Carcinogenicity:NTP:NO IARC:NO OSHA:NO
Health Hazards Acute and Chronic:WARNING! MAY CAUSE IRRITATION TO SKIN,
EYES & RESPIRATORY TRACT. AVOID BREATHING VAPOR & EYE/SKIN CONTACT.
Explanation of Carcinogenicity:NOT RELEVANT
Effects of Overexposure:SEE HEALTH HAZARDS.
Medical Cond Aggravated by Exposure:PERSONS W/PRE-EXISTING EYE, SKIN OR
RESPIRATORY DISORDERS MAY BE MORE SUSCEPTIBLE TO THE EFFECTS OF
THIS SUBSTANCE.
======================= First Aid Measures =======================
First Aid:INHAL:SEEK MEDICAL ASSISTANCE IF NECESSARY. SKIN:REMOVE
CONTAMINATED CLOTHING. FLUSH IMMEDIATELY W/COPIOUS AMOUNTS OF WATER
FOR AT LEAST 15 MINUTES. CALL MD. EYES:FLUSH IMMEDIATELY W/COPIOUS
AMOUNTS O F WATER FOR AT LEAST 15 MINUTES. CALL MD. INGEST:GET
MEDICAL ATTENTION IMMEDIATELY. TREAT SYMPTOMATICALLY &
SUPPORTIVELY.
===================== Fire Fighting Measures =====================
Flash Point Method:TCC
Flash Point:121F,49C
Lower Limits:0.7%
Upper Limits:6.1%
Extinguishing Media:CARBON DIOXIDE, DRY CHEMICAL POWDER, WATER SPRAY OR
REGULAR FOAM.
Fire Fighting Procedures:USE NIOSH/MSHA APPROVED SCBA & FULL PROTECTIVE
EQUIPMENT . FLAMMABLE, KEEP AWAY FROM HEAT, SPARKS & FLAME.
Unusual Fire/Explosion Hazard:MOD FIRE HAZ WHEN EXPOS TO HEAT/FLAME.
VAPS ARE HVR/AIR & MAY TRAVEL CONSIDERABLE DIST TO SOURCE OF IGNIT
& FLASH BACK. VAP-AIR MIXTS ARE EXPLO ABOVE FLASH PT.
Respiratory Protection:NIOSH/MSHA APPROVED RESPIRATOR APPROPRIATE FOR
EXPOSURE OF CONCERN . NOT REQUIRED UNDER NORMAL CONDITIONS OF USE.
Ventilation:MECHANICAL EXHAUST, FUME HOOD.
Protective Gloves:CHEMICAL RESISTANT GLOVES.
Eye Protection:ANSI APPROVED CHEM WORKERS GOGGS .
Other Protective Equipment:EYE WASH FOUNTAIN & DELUGE SHOWER WHICH MEET
ANSI DESIGN CRITERIA . PROTECTIVE APRON OR GOWN AS REQUIRED.
Work Hygienic Practices:NONE SPECIFIED BY MANUFACTURER.
Supplemental Safety and Health
NONE SPECIFIED BY MANUFACTURER.
================= Stability and Reactivity Data =================
Stability Indicator/Materials to Avoid:YES
VIOLENT REACTION MAY RESULT FROM EXPOSURE TO STRONG OXIDIZING AGENTS &
IODINE PENTAFLUORIDE.
Stability Condition to Avoid:INCOMPATIBLE SUBSTANCES.
Hazardous Decomposition Products:TOXIC OXIDES OF CARBON.
Waste Disposal Methods:ENSURE COMPLIANCE W/ALL LOCAL, STATE & FEDERAL
REGULATIONS OR CONTACT AN APPROVED & LICENSED DISPOSAL AGENCY.
Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.