MSDS NAME:TONER FOR USE IN MITA DC-2055, 807841
NIIN:00N062898
MSDS Number: BYSXG
=== Responsible Party ===
Company:KATUN CORP
Address:10951 BUSH LAKE RD
City:MINNEAPOLIS
State:MN
ZIP:55438
Country:US
Info Phone Num:612-941-9505
Emergency Phone Num:612-941-9505
CAGE:JO112
=== Contractor Identification ===
Company:KATUN CORP
Address:10951 BUSH LAKE RD
Box:City:MINNEAPOLIS
State:MN
ZIP:55438
Country:US
Phone:612-941-9505
CAGE:JO112
============= Composition/Information on Ingredients =============
Name:CARBON BLACK
CAS:1333-86-4
RTECS #:FF5800000
Fraction by Wt: 6%
OSHA PEL:3.5 MG/M3
ACGIH TLV:3.5 MG/M3
LD50 LC50 Mixture:NONE SPECIFIED BY MANUFACTURER.
Routes of Entry: Inhalation:YES Skin:NO Ingestion:YES
Reports of Carcinogenicity:NTP:NO IARC:NO OSHA:NO
Health Hazards Acute and Chronic:MINIMUM IRRITATION TO RESPIRATORY
TRACT MAY OCCUR AS W/EXPOSURE TO ANY NON-TOXIC DUST. IN
XEROX-SPONSORED CHRONIC INHAL STUDY IN RATS USING STYRENE/ACRYLATE
SPEC TEST TONER, THERE WERE NO LUNG CHGS AT ALL IN LOWEST EXPOS
LEVEL (1 MG/M3), LEVEL MOST RELEVANT TO POTNTL HUMAN EXPOS. VERY
SLIGHT DEGREE OF (EFTS OF OVEREXP)
Explanation of Carcinogenicity:NOT RELEVANT
Effects of Overexposure:HLTH HAZ: FIBROSIS WAS NOTED IN 25% OF ANIMALS
AT MID EXPOS LEVEL (4 MG/M3) WHILE SLIGHT DEGREE OF FIBROSIS WAS
OBSERVED AT HIGHEST EXPOS LEVEL (16 MG/M3) IN ALL ANIMALS. THESE
FINDINGS ARE ATTRIBUTED TO "LUNG OVERLOADING", A GENERIC RESPONSE
TO EXCESS AMTS OF ANY DUST RETAINED IN LUNGS FOR PRLNGD INTERVAL.
(SUPDAT)
Medical Cond Aggravated by Exposure:ACCUMULATION OF DUST IN THE
RESPIRATORY SYSTEM.
======================= First Aid Measures =======================
First Aid:INGEST: CALL MD IMMEDIATELY . SKIN: FLUSH W/COPIOUS AMOUNTS
OF WATER. CALL MD . INHAL: REMOVE TO FRESH AIR; IF EFFECTS OCCUR,
CONSULT MD. EYES: IN CASE OF CONTACT, IMMEDIATELY FLUSH EYES W ITH
WATER FOR AT LEAST 15 MINUTES.
===================== Fire Fighting Measures =====================
Extinguishing Media:CARBON DIOXIDE, DRY CHEMICAL, FOAM OR WATER.
Fire Fighting Procedures:USE NIOSH/MSHA APPRVD SCBA & FULL PROT EQUIP .
THIS MATL WILL BURN, PRODUCING CARBON MONOXIDE, CARBON DIOXIDE,
NO*X AS DECOMPOSITION PRODUCTS.
Unusual Fire/Explosion Hazard:TONER IS A COMBUSTIBLE POWDER; WHEN
DISPERS IN AIR, IT FORMS EXPLOSIVE MIXTURES.
Respiratory Protection:NONE REQUIRED WHEN USED AS INTENDED. USE
NIOSH/MSHA APPROVED RESPIRATOR APPROPRIATE FOR EXPOSURE OF CONCERN
.
Ventilation:NO SPECIAL REQUIREMENTS.
Protective Gloves:NONE REQUIRED WHEN USED AS INTENDED.
Eye Protection:NONE REQUIRED WHEN USED AS INTENDED.
Other Protective Equipment:NONE REQUIRED WHEN USED AS INTENDED.
Work Hygienic Practices:AVOID PROLONGED INHALATION OF EXCESSIVE DUST.
Supplemental Safety and Health
EFTS OF OVEREXP: THE SPEC TEST TONER WAS 10 TIMES MORE RESPIRABLE THAN
COMMERCIALLY AVAIL XEROX TONER TO COMPLY W/EPA TESTING PROTOCOL &
WOULD NOT FUNCTION PROPERLY IN XEROX EQUIP.
Waste Disposal Methods:WASTE MATERIAL MAY BE DUMPED OR INCINERATED
UNDER CONDITIONS WHICH MEET ALL FEDERAL, STATE AND LOCAL
ENVIRONMENTAL REGULATIONS.
Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.