ethylene glycol (sara 313) (cercla). %(wt): 0.00-4.36. propylene glycol. %(wt): 0.00-5.00. pigment volatile organic content: 1.35 - 1.72. vent:in vol & pattern to keep tlv of most haz ing below ing 5: during welding/flame cutting on surfaces coated resp prot: of particulate & gas & vap in confined areas, ing 7: resp prot may also be nec in any later mfg ops in
LD50 LC50 Mixture:NONE SPECIFIED BY MANUFACTURER.
Routes of Entry: Inhalation:YES Skin:NO Ingestion:NO
Reports of Carcinogenicity:NTP:NO IARC:NO OSHA:NO
Health Hazards Acute and Chronic:REPORTS HAVE ASSOCIATED REPEATED AND
PROLONGED OCCUPATIONAL OVEREXP TO SOLVENTS WITH PERM BRAIN &
NERVOUS SYSTEM DMG. INTENTIONAL MISUSE BY DELIBERATELY CONC &
INHALING CONTENTS MAY BE HARMFUL/FATAL. DO NOT BREATHE VAPORS OR
SPRAY MIST. MAY CONTAIN ONE/MORE REPORTED TERATOGENS/SUSPECTED
TERATOGENS.
Explanation of Carcinogenicity:NOT RELEVANT.
Effects of Overexposure:SEE HEALTH HAZARDS.
Medical Cond Aggravated by Exposure:NONE SPECIFIED BY MANUFACTURER.
======================= First Aid Measures =======================
First Aid:EYE: FLUSH W/LUKE WARM WATER FOR AT LEAST 15 MINS. GET MED
ATTN. SKIN: FLUSH WASH W/COPIOUS AMOUNTS OF LUKEWARM WATER. REMOVE
CONTAMD CLTHG PROMPTLY. INHAL: REMOVE EXPOSED INDIVIDUAL TO FRESH
AIR. ING EST: NEVER GIVE ANYTHING BY MOUTH TO ANUNCON PERS. IF
VICTIM IS CONSCIOUS & ALERT, VOMIT SHOULD BE INDUCED FOR INGESTIONS
FOR MORE THAN ONE SWALLOW)(1-2 TBLSP FOR AN ADULT) PREF W/SYRUP OF
(SUPDAT)
===================== Fire Fighting Measures =====================
Flash Point Method:TCC
Extinguishing Media:USE MEDIA SUITABLE FOR SURROUNDING FIRE.
Fire Fighting Procedures:WEAR NIOSH/MSHA APPROVED SCBA & FULL
PROTECTIVE EQUIPMENT.
Unusual Fire/Explosion Hazard:CONTAINERS EXPOSED TO INTENSE HEAT FROM
FIRES SHOULD BE COOLED W/WATER TO PREVENT VAPOR PRESSURE BUILDUP
WHICH COULD RESULT IN CONTAINER RUPTURE.
Spill Release Procedures:DO NOT FLUSH TO SEWER, WATERSHED OR WATERWAY.
Neutralizing Agent:NONE SPECIFIED BY MANUFACTURER.
====================== Handling and Storage ======================
Handling and Storage Precautions:KEEP FROM FREEZING. DO NOT STORE
>120F. DO NOT TAKE INTERNALLY. CLOSE CONTAINER AFTER EACH USE.
Other Precautions:KEEP OUT OF REACH OF CHILDREN.
Respiratory Protection:IN OUTDOOR/OPEN AREAS, USE (NIOSH/MSHA
APPRVD)MECH FILTER RESP TO REMOVE SOLID AIRBORNE PARTICLES OF
OVERSPRAY DURING SPRAY APPLIC IN RESTRICTED VENT AREAS,
USE(NIOSH/MSHA APPRVD) CHEMICAL MECH FILTER S DESIGNED TO REMOVE
COMBINATION(ING 7)
Ventilation:USE VENT AS REQD TO CONTROL VAP CONC. AVOID PRLNGD/RPTD
BRTHG OF VAPORS. PROVIDE GENL DILUTION/LOC EXHST VENT (ING 5)
Protective Gloves:IMPERVIOUS GLOVES.
Eye Protection:ANSI APPRVD CHEM WORKERS GOGGS.
Other Protective Equipment:EMERGENCY EYEWASH & DELUGE SHOWER MEETING
ANSI DESIGN CRITERIA.
Work Hygienic Practices:WASH HANDS THORO BEFORE EATING & USING
WASHROOM. REMOVE CONTAMD CLTHG IMMED & DO NOT WEAR IT UNTIL IT HAS
BEEN(SUPDAT)
Supplemental Safety and Health
TRADENAME/PART NO#: ACRYLIC SEMI-GLOSS HOUSE & TRIM PAINT.
%VOLAT:62.46-66.78. FIRST AID PROC:IPECAC UNDER DIRECTION FROM
MD/POIS CNTRL CENTER. IF SYRUP OF IPEPCAC IS NOT AVAIL, VOMIT CAN
BE INDUCED B Y GENTLY PLACING 2 FINGERS IN BACK OF THROAT. IF POSS,
DO NOT LEAVE VICTIM UNATTENDED. HYGIENE PRAC: PROPERLY LAUNDERED.
Boiling Pt:B.P. Text:>212F,>100C
Vapor Pres:17.0 @ 68F
Vapor Density:HVR/AIR
Spec Gravity:1.09-1.29
Evaporation Rate & Reference:SLOWER THAN BUTYL ACETATE
Appearance and Odor:NONE SPECIFIED BY MANUFACTURER.
Percent Volatiles by Volume:SUPDAT
================= Stability and Reactivity Data =================
Stability Indicator/Materials to Avoid:YES
THESE PRODUCTS ARE INCOMPATIBLE WITH STRONG ACIDS.
Stability Condition to Avoid:NONE SPECIFIED BY MANUFACTURER.
Hazardous Decomposition Products:MAY PRDCE HAZ FUMES WHEN HEATED TO
DECOMP. FUMES MAY CNTN CARBON MONOXIDE, CARBON DIOXIDE & OXIDES OF
NITROGEN.
Waste Disposal Methods:DISPOSE OF IN ACCORDANCE W/LOCAL, STATE &
FEDERAL REGULATIONS.
Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.