LD50 LC50 Mixture:NONE SPECIFIED BY MANUFACTURER.
Routes of Entry: Inhalation:YES Skin:YES Ingestion:YES
Reports of Carcinogenicity:NTP:NO IARC:NO OSHA:NO
Health Hazards Acute and Chronic:CORROSIVE. AVOID DIRECT PHYSICAL
CONTACT! LACHRYMATOR - CAUSES SEV EYE IRRIT. VAPS &/DIRECT EYE CONT
CAN CAUSE SEV EYE BURNS. CAN CAUSE SKIN BURNS, INGESTION MAY CAUSE
SEVERE CORROSION OF MOUTH. DUST &/VAPS CAN CAUSE IRRIT TO RESP
TRACT. CAN BE IRRIT TO MUC MEMBS. CAN BE FATAL IF INHALED! (EFTS OF
OVEREXP)
Explanation of Carcinogenicity:NOT RELEVANT.
Effects of Overexposure:HLTH HAZ: POSSIBLE CHOLINESTERASE INHIBITOR -
MAY CAUSE SEIZURES, NAUSEA, VOMITING, AIRWAY OBSTRUCTION
&/INCREASED MUCOUS SECRETIONS IN LUNGS.
Medical Cond Aggravated by Exposure:NONE SPECIFIED BY MANUFACTURER.
======================= First Aid Measures =======================
First Aid:AN ANTIDOTE IS SUBSTANCE INTENDED TO COUNTERACT EFT OF POIS.
IT SHOULD BE ADMIN ONLY BY MD/TRAINED EMER PERS. EYE: FLUSH
CONTINUOUSLY W/WATER FOR AT LEAST 15 MINS. SKIN: FLUSH W/WATER FOR
15-20 MINS. IF NO BURNS HAVE OCCURRED-USE SOAP & WATER TO CLEANSE
SKIN. INHAL: REMOVE PATIENT TO FRESH AIR. ADMIN O*2 IF PATIENT IS
HAVING DFCLTY BRTHG. IF PATIENT HAS STOPPED BRTHG ADMIN ARTF RESP.
IF(SUPDAT)
===================== Fire Fighting Measures =====================
Flash Point:234F,112C
Extinguishing Media:CARBON DIOXIDE, DRY CHEMICAL POWDER. DO NOT USE
WATER.
Fire Fighting Procedures:WEAR NIOSH/MSHA APPROVED SCBA & FULL
PROTECTIVE EQUIPMENT.
Unusual Fire/Explosion Hazard:NONE SPECIFIED BY MANUFACTURER.
Spill Release Procedures:EVACUATE AREA. WEAR NIOSH/MSHA/OSHA REGULATED
EQUIPMENT. VENTILATE AREA. ABSORB ON VERMICULITE OR SIMILAR MATL.
SWEEP UP & PLACE IN APPROP CNTNR. HOLD FOR DISPOSAL. WASH CONTAMD
SURFACES TO REMOVE ANY RESIDUES.
Neutralizing Agent:NONE SPECIFIED BY MANUFACTURER.
====================== Handling and Storage ======================
Handling and Storage Precautions:KEEP TIGHTLY CLOSED AND STORE IN A
COOL DRY PLACE. STORE ONLY W/COMPATIBLE CHEMICALS.
Other Precautions:AVOID CONTACT W/SKIN, EYES, & CLTHG. CONTACT LENSES
SHOULD NOT BE WORN IN THE LAB. THIS PROD IS FURNISHED FOR LAB USE
ONLY! PRODUCTS MAY NOT BE USED AS DRUGS, COSMETICS,
AGRICULTURAL/PESTICIDAL PRODUC TS, FOOD ADDITIVES/AS HOUSEHOLD
CHEMS.
Respiratory Protection:USE NIOSH/MSHA APPROVED RESPIRATOR APPROPRIATE
FOR EXPOSURE OF CONCERN.
Ventilation:THIS CHEMICAL SHOULD BE HANDLED ONLY IN A HOOD.
Protective Gloves:IMPERVIOUS GLOVES.
Eye Protection:ANSI APPRVD CHEM WORKERS GOGGS(SUPDAT)
Other Protective Equipment:EMERGENCY EYEWASH & DELUGE SHOWER MEETING
ANSI DESIGN CRITERIA.
Work Hygienic Practices:NONE SPECIFIED BY MANUFACTURER.
Supplemental Safety and Health
FIRST AID PROC: PATIENT IS IN CARDIAC ARREST ADMIN CPR. CONTINUE LIFE
SUPPORTING MEASURES UNTIL MEDICAL ASSISTANCE HAS ARRIVED. GET MED
ATTN IF NECESSARY. DO NOT WEAR SHOES OR CLOTHING UNTIL ABSOLUTEL Y
FREE OF ALL CHEMICAL ODORS. EYE PROT:& FULL LENGTH FACESHIELD.
Waste Disposal Methods:BURN IN CHEMICAL INCINERATOR EQUIPPED WITH AN
AFTERBURNER AND SCRUBBER. DISPOSE OF IN ACCORDANCE W/LOCAL, STATE &
FEDERAL REGULATIONS.
Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.