LD50 LC50 Mixture:LD50(RAT):3500 MG/KG
Routes of Entry: Inhalation:YES Skin:YES Ingestion:YES
Reports of Carcinogenicity:NTP:NO IARC:NO OSHA:NO
Health Hazards Acute and Chronic:CONTACT LENSES SHOULD NOT BE WORN IN
THE LABORATORY. ALL CHEMICALS SHOULD BE CONSIDERED HAZARDOUS-AVOID
DIRECT PHYSICAL CONTACT! SUSPECTED CARCINOGEN-MAY PRODUCE CANCER.
POSSIBLE TERATOGEN-CAUSES EMBR YO-FETAL DAMAGE. CAN BE HARMFUL IF
INHALED, SWALLOWED, AND ABSORBED THROUGH THE SKIN. CAN CAUSE EYE
(EFTS OF OVEREXP)
Explanation of Carcinogenicity:NOT RELEVANT
Effects of Overexposure:HLTH HAZS:AND SKIN IRRITATION. DUST AND/OR
VAPORS CAN CAUSE IRRITATION TO RESPIRATORY TRACT. CAN BE IRRITATING
TO MUCOUS MEMBRANES.
Medical Cond Aggravated by Exposure:NONE SPECIFIED BY MANUFACTURER.
======================= First Aid Measures =======================
First Aid:INGEST:CALL MD IMMED AN ANTIDOTE IS SUBSTANCE INTENDED TO
COUNTERACT EFT OF POIS. IT SHOULD BE ADMIN BY MD/TRAINED EMER PERS.
MED ADVICE CAN BE OBTAINED FROM POIS CTL CTR. EYES:FLUSH CONTINUOUS
LY W/WATER FOR @ LST 15 MIN. SKIN:FLUSHW/WATER FOR 15-20 MIN. IF NO
BURNS HAVE OCCURRED-USE SOAP & WATER TO CLEANSE SKIN. INHAL:REMOVE
PATIENT TO FRESH AIR. ADMIN OXYG IF PATIENT IS HAVING (SUPDAT)
===================== Fire Fighting Measures =====================
Flash Point:234F,112C
Extinguishing Media:CARBON DIOXIDE, DRY CHEMICAL POWDER OR WATER SPRAY.
Fire Fighting Procedures:WEAR NIOSH/MSHA APPROVED SCBA & FULL
PROTECTIVE EQUIPMENT .
Unusual Fire/Explosion Hazard:NONE SPECIFIED BY MANUFACTURER.
Spill Release Procedures:EVACUATE AREA. WEAR APPROPRIATE OSHA-REGULATED
EQUIPMENT. VENTILATE AREA. ABSORB ON VERMICULITE OR SIMILAR
MATERIAL. SWEEP UP AND PLACE IN AN APPROPRIATE CONTAINER. HOLD FOR
DISPOSAL. WASH CONTAMINATE D SURFACES TO REMOVE ANY RESIDUES.
Neutralizing Agent:NONE SPECIFIED BY MANUFACTURER.
====================== Handling and Storage ======================
Handling and Storage Precautions:AVOID CONTACT WITH SKIN, EYES AND
CLOTHING. KEEP TIGHTLY CLOSED & STORE IN A COOL, DRY PLACE. STORE
ONLY WITH COMPATIBLE CHEMICALS.
Other Precautions:PERSONS NOT SPECIFICALLY & PROPERLY TRAINED SHOULD
NOT HNDL CHEM/CNTNR. PROD IS FURNISHED FOR LAB USE ONLY! MFR'S
PRODS MAY NOT BE USED AS DRUGS, COSMETICS, AGRICULTURAL/PESTICIDAL
PRODS, FOOD ADDITIV ES/AS HOUSEHOLD CHEMS.
Respiratory Protection:USE NIOSH/MSHA APPROVED RESPIRATOR APPROPRIATE
FOR EXPOSURE OF CONCERN . USE APPROPRIATE OSHA/MSMA APPROVED SAFETY
EQUIPMENT.
Ventilation:THIS CHEMICAL SHOULD BE HANDLED ONLY IN A HOOD.
Protective Gloves:IMPERVIOUS GLOVES .
Eye Protection:ANSI APPROVED CHEM WORKERS GOGGS .
Other Protective Equipment:ANSI APPROVED EMERGENCY EYE WASH AND DELUGE
SHOWER .
Work Hygienic Practices:NONE SPECIFIED BY MANUFACTURER.
Supplemental Safety and Health
FIRST AID PROC:DIFFICULTY BREATHING. IF PATIENT HAS STOPPED BREATHING
ADMINISTER ARTIFICIAL RESPIRATION. IF PATIENT IS IN CARDIAC ARREST
ADMINISTER CPR. CONTINUE LIFE SUPPORTING MEASURES UNTIL MEDICAL
ASSISTANCE HAS ARRIVED.
Waste Disposal Methods:DISPOSAL MUST BE I/A/W FEDERAL, STATE & LOCAL
REGULATIONS . BURN IN A CHEMICAL INCINERATOR EQUIPPED WITH AN
AFTERBURNER AND SCRUBBER.
Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.