===================== Product Identification =====================
MSDS NAME:NEW ELECTRO KLEEN, 5010
NIIN:00N070243
MSDS Number: CBLKS
=== Responsible Party ===
Company:PRECISION SUPPLY
Address:4450 CALIFORNIA AVE K137
City:BAKERSFIELD
State:CA
ZIP:93309
Country:US
Info Phone Num:305-974-5440
Emergency Phone Num:800-255-3924
CAGE:JO046
=== Contractor Identification ===
Company:PRECISION SUPPLY
Address:4450 CALIFORNIA AVE SUITE 137
Box:City:BAKERFIELD
State:CA
ZIP:93309
Country:US
Phone:805-871-8492
CAGE:0G6E4
Company:PRECISION SUPPLY
Address:4450 CALIFORNIA AVE K137
Box:City:BAKERSFIELD
State:CA
ZIP:93309
Country:US
Phone:305-974-5440
CAGE:JO046
============= Composition/Information on Ingredients =============
Name:ETHANE, 1,1-DICHLORO-1-FLUORO-
(1,1-DICHLORO-1-FLUOROETHANE) (SARA 313)
CAS:1717-00-6
RTECS #:KI0997000
Fraction by Wt: 80-100%
OSHA PEL:N/K
ACGIH TLV:N/K
Ozone Depleting Chemical:2
Name:CARBON DIOXIDE
CAS:124-38-9
RTECS #:FF6400000
Fraction by Wt: 01-05%
OSHA PEL:5000 PPM
ACGIH TLV:5000 PPM/30000 STEL
===================== Hazards Identification =====================
LD50 LC50 Mixture:NONE SPECIFIED BY MANUFACTURER.
Routes of Entry: Inhalation:YES Skin:YES Ingestion:YES
Reports of Carcinogenicity:NTP:NO IARC:NO OSHA:NO
Health Hazards Acute and Chronic:ACUTE:EYES:MAY CAUSE SLIGHT IRRIT BUT
DOES NOT INJURE EYE TISS. SKIN:FREQUENT/PRLNGD CONT MAY CAUSE
IRRIT. INHAL:INHAL OF MIST CAN CAUSE IRRIT OF NASAL & RESP
PASSAGES. ABUSIVE/EXCESS INHAL MAY CAUSE IRRIT TO UPPER RESP
TRACT, DIZZ, NAUS, & OTHER CNS EFTS. INGEST:CAN CAUSE GI IRRIT,
NAUS, VOMIT AND (EFTS OF OVEREXP)
Explanation of Carcinogenicity:NOT RELEVANT.
Effects of Overexposure:HLTH HAZ:DIARR. ASPIR OF MATL INTO LUNGS CAN
CAUSE CHEM PNEUM. MIN TOX. CHLOROFLUOROCARB (CFC) MATLS HAVE PRDCED
SENSIT OF MYOCARDIUM TO EPINEPHRINE IN LAB ANIMALS & COULD HAVE
SIMILAR EFT IN HUMANS. ADRENOMIMETICS (I.E., EPINEPHRINE) MAY BE
CONTRA-INDICATED EXCEPT FOR LIFE-SUSTAINING USES IN HUMANS ACUTELY
OR (SUPDAT)
Medical Cond Aggravated by Exposure:NONE SPECIFIED BY MANUFACTURER.
======================= First Aid Measures =======================
Eyes:FLUSH W/LG AMTS OF COOL RUNNING WATER FOR @ LEAST 15
MINS WHILE HOLDING UPPER & LOWER LIDS OPEN. IF IRRIT PERSISTS GET
MED ATTN IMMED. SKIN:WASH W/SOAP & WATER. IF IRRIT PERSISTS SEEK
MED ATTN. I NHAL:REMOVE TO FRESH AIR. SEEK MED ATTNIMMED. IF BRTHG
STOPS GIVE ARTF RESP. INGEST:DO NOT INDUCE VOMIT. SEEK MED ATTN
IMMED.
===================== Fire Fighting Measures =====================
Flash Point:NONE
Extinguishing Media:FOAM, CO*2, DRY MEDIA.
Fire Fighting Procedures:WEAR NIOSH/MSHA APPROVED PRESSURE DEMAND SCBA
& FULL PROTECTIVE EQUIPMENT .
Unusual Fire/Explosion Hazard:THERMAL DECOMPOSITION PRODUCTS MAY
INCLUDE FLUORIDES, CHLORIDES, AND PHOSGENE . EXPOSURE TO
TEMPERATURES ABOVE 120F MAY CAUSE BURSTING.
================== Accidental Release Measures ==================
Spill Release Procedures:ALLOW PROPELLANT TO EVAP. MAINTAIN LOCAL
EXHAUST & ADEQ VENT. NO SMKNG. KEEP SPKS, HEAT SOURCES & OPEN FLAME
FAR AWAY FROM SPILL/LEAK. COVER W/ABSORB MATL & SWEEP UP. WASH AREA
TO PVNT SLIPPING. DISPO SE OF SOAKED ABSORB MATL I/A/W
FEDERAL,(SUPDAT)
Neutralizing Agent:NONE SPECIFIED BY MANUFACTURER.
====================== Handling and Storage ======================
Handling and Storage Precautions:INDUST & INSTITUTIONAL USE ONLY. STORE
IN COOL, DRY AREA AWAY FROM HEAT/OPEN FLAME. DO NOT STORE @ TEMPS
>120F. NFPA CODE 30B RATING:LEV 1 AEROSOL.
Other Precautions:NO SMOKING IN AREA OF USE. DO NOT USE IN GENERAL
VICINITY OF ARC WELDING, OPEN FLAMES OR HOT SURFACES. HEAT AND/OR
UV RADIATION MAY CAUSE THE FORMATION OF CHLORIDES, FLUORIDES OR
PHOSGENE .
============= Exposure Controls/Personal Protection =============
Respiratory Protection:NONE NEEDED FOR PROPER USE I/A/W LABEL
DIRECTIONS. NIOSH/MSHA APPROVED RESPIRATORY APPROPRIATE FOR
EXPOSURE OF CONCERN .
Ventilation:PROVIDE LOCAL EXHAUST TO KEEP TLV OF INGRED SECTION BELOW
ACCEPTABLE LIMITS.
Protective Gloves:CHEMICAL RESISTANT GLOVES.
Eye Protection:ANSI APPRVD CHEM WORKERS GOGGLES .
Other Protective Equipment:ANSI APPRVD EMER EYE WASH & DELUGE SHOWER .
Work Hygienic Practices:NONE SPECIFIED BY MANUFACTURER.
Supplemental Safety and Health
SPEC GRAV:1.220 @ 75F (H*2O=1). EFTS OF OVEREXP:CHRONICALLY EXPOSED TO
CFCS . SPILL RELEASE:STATE AND LOCAL LAWS.
================== Physical/Chemical Properties ==================
Boiling Pt:B.P. Text:90.0F,32.2C
Vapor Pres:80 PSIG
Vapor Density:>1
Spec Gravity:SUPDAT
Evaporation Rate & Reference:NOT KNOWN
Solubility in Water:SLIGHT
Appearance and Odor:CLEAR COLORLESS LIQUID, FAINT ETHER-LIKE ODOR.
================= Stability and Reactivity Data =================
Stability Indicator/Materials to Avoid:YES
AVOID CONT WITH STRONG OXIDIZING AGENTS, ZINC, REACTIVE METALS,
ALUMINUM, MAGNESIUM.
Stability Condition to Avoid:NONE SPECIFIED BY MANUFACTURER.
Hazardous Decomposition Products:CHLORIDES, FLUORIDES & PHOSGENE.
CARBON DIOXIDE, CARBON MONOXIDE, HYDROGEN CHLORIDE, HYDROGEN
FLUORIDE & CHLORINE.
==================== Disposal Considerations ====================
Waste Disposal Methods:AEROSOL CANS, WHEN EMPTIED & DEPRESSURIZED THRU
NORM USE, POSE NO DISPOSAL HAZARD & SHOULD BE RECYCLED. CONSULT
FEDERAL, STATE AND LOCAL AUTHORITIES FOR APPROVED PROCEDURES.
Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.
*** END OF RECORD *** |
|