===================== Product Identification =====================
MSDS NAME:OXYGEN IN ARGON (1 PPM TO 50%), G-155
NIIN:00N071232
MSDS Number: CBNKG
=== Responsible Party ===
Company:AIRCO GASES DIV BOC GROUP INC
Address:575 MOUNTAIN AVE
City:MURRAY HILL
State:NJ
ZIP:07974
Country:US
Info Phone Num:908-464-8100
Emergency Phone Num:800-424-9300 (CHEMTREC)
CAGE:HO800
=== Contractor Identification ===
Company:AIRCO GASES DIV BOC GROUP INC
Address:575 MOUNTAIN AVE
Box:City:MURRAY HILL
State:NJ
ZIP:07974
Country:US
Phone:908-464-8100
CAGE:HO800
Company:AIRCO INC, AIRCO INDUSTRIAL GASES DIV.
Address:575 MOUNTAIN AVE
Box:City:MURRAY HILL
State:NJ
ZIP:07974-2006
Country:US
Phone:800-424-9300(CHEMTREC)
CAGE:00741
============= Composition/Information on Ingredients =============
Name:ARGON
CAS:7440-37-1
RTECS #:CF2300000
Fraction by Wt: 50-99.9%
OSHA PEL:N/K
ACGIH TLV:ASPHYXIANT
Name:OXYGEN
CAS:7782-44-7
RTECS #:RS2060000
Fraction by Wt: <50%
OSHA PEL:N/K
ACGIH TLV:N/K
Name:SUP DAT: SYS TO PVNT FULL CYLS BEING STORED FOR EXCESS
PERIODS OF TIME. PROT CYLS FROM PHYSICAL DMG. STORE IN (ING 4)
RTECS #:9999999ZZ
Name:ING 3: COOL, DRY, WELL-VENTD AREA AWAY FROM HEAVILY
TRAFFICKED AREAS & EMER EXITS. DO NOT ALLOW TEMP WHERE CYLS (ING 5)
RTECS #:9999999ZZ
Name:ING 4: ARE STORED TO EXCEED 125F. CYLS SHOULD BE STORED
UPRIGHT & FIRMLY SECURED TO PVNT FALLING/BEING KNOCKED (ING 6)
RTECS #:9999999ZZ
Name:ING 5: OVER. FULL & EMPTY CYLS SHOULD BE SEGREGATED. FOR
ADDNL STOR REC, CONSULT COMPRESSED GAS ASSOCIATION (ING 7)
RTECS #:9999999ZZ
Name:ING 6: PAMPHLET P-1. NEVER CARRY COMPRESSED GAS CYL/CONTR
OF GAS CYL IN CRYOGENIC LIQ FORM IN ENCLSD SPACE SUCH (ING 8)
RTECS #:9999999ZZ
Name:ING 7: AS A CAR TRUNK, VAN/STATION WAGON. LEAK CAN RSLT IN
FIRE, EXPLO, ASPHY/TOX EXPOS. THESE MIX ARE NONCORR (ING 9)
RTECS #:9999999ZZ
Name:ING 8: & MAY BE USED W/ANY COMMON STRUCTURAL MATL.
COMPRESSED GAS CYLS SHOULD NOT BE REFILLED EXCEPT BY (ING 10)
RTECS #:9999999ZZ
Name:ING 9: QUALIFIED PRODUCERS OF COMPRESSED GAS. SHIPMENT OF
COMPRESSED GAS CYL WHICH HAS NOT BEEN FILLED BY THE (ING 11)
RTECS #:9999999ZZ
Name:ING 10: OWNER OR WITH ITS (WRITTEN) CONSENT IS A VIOLATION
OF FEDERAL LAW (49 CFR).
RTECS #:9999999ZZ
===================== Hazards Identification =====================
LD50 LC50 Mixture:NONE SPECIFIED BY MANUFACTURER.
Routes of Entry: Inhalation:YES Skin:YES Ingestion:YES
Reports of Carcinogenicity:NTP:NO IARC:NO OSHA:NO
Health Hazards Acute and Chronic:ACUTE: INHAL: EFTS OF EXPOS TO HIGH
CONCS OF ARGON SO FAR AS TO DISPLACE OXYGEN CONTENT IN AIR NEC FOR
LIFE ARE HDCH, DIZZ, LABORED BRTHG & EVENTUAL UNCON. MAINTAIN
OXYGEN LEVELS ABOVE 19.5% AT SEA LE VEL. TOX INFO: MIX W/LESS THAN
19.5% OXYGEN ARE INACTIVE BIOLOGICALLY & ESSENTIALLY NONTOX.
THEREFORE, (EFTS OF OVEREXP)
Explanation of Carcinogenicity:NOT RELEVANT.
Effects of Overexposure:HLTH HAZ: THE MAJOR HAZ IS THAT OF OXYGEN
DEFICIENCY DUE TO DISPLACEMENT. CHRONIC: NONE SPECIFIED BY
MANUFACTURER.
Medical Cond Aggravated by Exposure:NONE SPECIFIED BY MANUFACTURER.
======================= First Aid Measures =======================
First Aid:PROMPT MED ATTN IS MANDATORY IN ALL CASES OF OVEREXP. RESCUE
PERS SHOULD BE EQUIPPED W/NIOSH/MSHA APPRVD SCBA. INHAL: VICTIMS
SHOULD BE ASSISTED TO UNCON AREA & INHALE FRESH AIR. QUICK REMOVAL
FROM CO NTAM AREA IS MOST IMPORTANT. IF BRTHG HAS STOPPED ADMIN
ARTF RESUSCITATION & SUPPLEMENTAL OXYGEN. FURTHER TREATMENT SHOULD
BE SYMPTOMATIC & SUPPORTIVE. SKIN: FLUSH W/COPIOUS AMTS OF WATER.
(SUP DAT)
===================== Fire Fighting Measures =====================
Flash Point:NONE
Lower Limits:NONE
Upper Limits:NONE
Extinguishing Media:NON-FLAMMABLE, INERT GAS. USE ANY MEDIA SUITABLE
FOR SURROUNDING FIRE. USE WATER SPRAY TO COOL FIRE EXPOSED
CONTAINERS.
Fire Fighting Procedures:WEAR NIOSH/MSHA APPROVED SCBA & FULL
PROTECTIVE EQUIPMENT . NO SPECIAL REQUIREMENTS. USE PRECAUTIONS FOR
SURROUNDING FIRE.
Unusual Fire/Explosion Hazard:ELECTRICAL CLASSIFICIATION:
NON-HAZARDOUS. HIGH CONCENTRATIONS OF OXYGEN MAY ACCELERATE FIRES.
================== Accidental Release Measures ==================
Spill Release Procedures:EVACUATE ALL PERSONNEL FROM AFFECTED AREA. USE
APPROPRIATE PROTECTIVE EQUIPMENT INCLUDING NIOSH/MSHA APPROVED
SCBA. IF LEAK IS IN CONTAINER OR CONTAINER VALVE, CONTACT CHEMTREC
FOR EMERGENCY ASSISTANC E OR YOUR CLOSEST AIRCO LOCATION.
Neutralizing Agent:NONE SPECIFIED BY MANUFACTURER.
====================== Handling and Storage ======================
Handling and Storage Precautions:USE ONLY IN WELL-VENTD AREAS. VALVE
PROT CAPS MUST REMAIN IN PLACE UNLESS CONTR IS SECURED W/VALVE
OUTLET PIPED TO USE POINT.
Other Precautions:DO NOT DRAG, SLIDE/ROLL CYLS. USE SUITABLE HAND TRUCK
FOR CYL MOVEMENT. USE PRESS REDUCING REGULATOR WHEN CONNECTING CYL
TO LOWER PRESS (<3000 PSIG) PIPING/SYS. DO NOT HEAT CYL BY ANY
MEANS TO INCR DI SCHARGE RATE OF PROD FROM CYL. (SUP DAT)
============= Exposure Controls/Personal Protection =============
Respiratory Protection:A TYPE C NIOSH/MSHA APPROVED RESPIRATOR WITH
FULL FACEPIECE OR NIOSH/MSHA APPROVED SCBA SHOULD BE AVAILABLE FOR
EMERGENCY USE.
Ventilation:USE LOC EXHAUST/GEN VENT TO PVNT ACCUM OF HIGH CONCS WHICH
MAY REDUCE OXYGEN LEVEL IN AIR TO LESS THAN 18 MOLAR PERCENT.
Protective Gloves:IMPERVIOUS GLOVES .
Eye Protection:ANSI APPRVD CHEM WORKERS GOGGS .
Other Protective Equipment:EMERGENCY EYEWASH & DELUGE SHOWER MEETING
ANSI DESIGN CRITERIA . SAFETY SHOES.
Work Hygienic Practices:NONE SPECIFIED BY MANUFACTURER.
Supplemental Safety and Health
FIRS AID PROC: SEE MD . EYES: IF IRRIT DEVELOPS, WASH W/WATER FOR AT
LEAST 15 MIN & CONSULT MD. INGEST: CALL MD IMMED . WASTE DISP METH:
DISP OF I/A/W LOC, STATE & FED REGS . OTHER P REC: USE CHECK
VALVE/TRAP IN DISCHARGE LINE TO PVNT HAZ BACK FLOW INTO SYS. USE
"FIRST IN-FIRST OUT" INVENTORY (ING 3)
================== Physical/Chemical Properties ==================
Melt/Freeze Pt:M.P/F.P Text:-309F,-189C
Vapor Density:1.38
Solubility in Water:VERY SLIGHT
Appearance and Odor:COLORLESS GAS, ODORLESS
================= Stability and Reactivity Data =================
Stability Indicator/Materials to Avoid:YES
NONE KNOWN.
Stability Condition to Avoid:NONE SPECIFIED BY MANUFACTURER.
Hazardous Decomposition Products:NONE KNOWN.
==================== Disposal Considerations ====================
Waste Disposal Methods:DO NOT ATTEMPT TO DISPOSE OF WASTE/UNUSED QTYS.
RETURN IN SHIPPING CONTR PROPERLY LABELED, W/ANY VALVE OUTLET
PLUGS/CAPS SECURE & VALVE PROT CAP IN PLACE TO AIRCO FOR PROPER
DISP. SARA HAZ CLASSES: FI RE HAZ. SUDDEN RELEASE OF PRESS HAZ.
(SUP DAT)
Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.
*** END OF RECORD *** |
|