Search   
MSDS  
:
 BARIUM CYANIDE
CAS  
:
 542-62-1
NAME  
:
 barium cyanide  (sara iii)
inert ients.
=====================  Product Identification  =====================

MSDS NAME:BARIUM CYANIDE
NIIN:00-241-8420
MSDS Number: BDMPB
=== Responsible Party ===
Company:SPECTRUM CHEMICAL MFG CORP(MFR),CHEMICAL COMM.(DIS
Address:14422 SOUTH SAN PEDRO STREET
City:GARDENA
State:CA
ZIP:90248-2027
Country:US
Info Phone Num:213-516-8000
Emergency Phone Num:213-516-8000
CAGE:63415
=== Contractor Identification ===
Company:SPECTRUM LABORATORY PRODUCTS INC
Address:14422 S SAN PEDRO ST
Box:City:GARDENA
State:CA
ZIP:90248-2027
Country:US
Phone:310-516-8000/FAX: 310-516-9843
CAGE:63415

=============  Composition/Information on Ingredients  =============

Name:BARIUM CYANIDE  (SARA III)
CAS:542-62-1
RTECS #:CQ8785000
Fraction by Wt: 99.0%
OSHA PEL:0.5 MG SOLUBLE BA/M3
ACGIH TLV:0.5 MG BA/M3; 9192

Name:INERT INGREDIENTS.
Fraction by Wt: 1.0%

=====================  Hazards Identification  =====================

Effects of Overexposure:HIGHLY TOXIC;MAY BE RAPIDLY FATAL IF SWALLOWED
    OR INHALED.CAUSES EYE BURNS,MAY IRRITATE SKIN.

=======================  First Aid Measures  =======================

First Aid:CALL A DOCTOR AT ONCE.STUDY AND PLAN FIRST AID & ACTION PRIOR
    TO WORKING WITH CYANIDE.INHAL:USE AMYL NITRITE PEARL IN CLOTH &
    HOLD UNDER NOSE FOR 15 SEC.REPEAT 5 TIMES AT ABOUT 15 SECS
    INTERVALS.USE A RTIFICIAL RESPIRATION IF BREATHING STOPS(SEE PREC)

=====================  Fire Fighting Measures  =====================

Extinguishing Media:AIRFOAM OR WATER FOG PREFERRED
Fire Fighting Procedures:DO NOT ALLOW H*2O CONTAINING CYANIDE TO ENTER
    H*2O COURSE
Unusual Fire/Explosion Hazard:CONTACT WITH ACID MAY RELEASE POISONOUS &
    FLAMMABLE HCN GAS.

==================  Accidental Release Measures  ==================

Spill Release Procedures:SWEEP UP SPILLAGE & RETAIN IN COVERED
    CONTAINER FOR DISPOSAL.DECONTAMINATE SPILL AREA WITH SODIUM OR
    CALCIUM HYPOCHLORITE SOLUTION

======================	Handling and Storage  ======================

Handling and Storage Precautions:STOR IN DRY,WELL VENTILATED AREA;KEEP
    CONT.CLOSED.USE ONLY DRY,CLEAR UTENSILS IN HANDLING.DO NOT STORE
    W/ACIDS,WEAK ALKALIES OR OXIDIZERS.KEEP FR FOOD
Other Precautions:FIRST AID(CONTD):INGESTION:USE AMYL NITRITE PEAL IN
    CLOTH UNDER NOSE FOR 15 SECS.IF CONSCIOUS GIVE PATIENT 1 PT OF 1 %
    SODIUM THIOSULFATE SOLU,INDUCE VOMIT.EYES/SKIN:FLUSH W/WATER FOR 15
    MINS.

=============  Exposure Controls/Personal Protection  =============

Respiratory Protection:DUST FILTER RESPIRATOR >TLVS;AIR SUPPLIED MASK
    OR SELF-CONT.BRTHG.
Ventilation:LOCAL EXHAUST OR MECHANICAL
Protective Gloves:RUBBER;DRY CTN.
Eye Protection:SPLASH GOGGLES
Other Protective Equipment:RUBBER OVERSHOES.HAT & LONG SLEEVE SHIRT
Supplemental Safety and Health
SPECIAL FIRE FIGHTING PROCEDURES (CONTD):OR INTO SEWER WHICH MAY
    CONTAIN ACID,CONTACT WITH ACID MAY RELEASE POISONOUS & FLAMMABLE
    GAS.

==================  Physical/Chemical Properties  ==================

HCC:T2
Solubility in Water:APPRECIABLE
Appearance and Odor:CRYSTALS,CYANIDE ODOR.

=================  Stability and Reactivity Data  =================

Stability Indicator/Materials to Avoid:YES
CONTACT W/ACIDS OR WEAK ALKALIES-RELEASES POIS.&FLAM.HCN(G)
Hazardous Decomposition Products:CONTACT W/ACIDS OR WEAK
    ALKALIES-RELEASES POIS.&FLAM.HCN(G)

====================  Disposal Considerations  ====================

Waste Disposal Methods:COMPLY WITH FEDERAL,STATE & LOCAL REGULATIONS.DO
    NOT FLUSH BARIUM CYANIDE INTO SEWERS.IF APPROVED NEUTRALIZE
    W/SODIUM OR CALCIUM HYPOCHLORITE OR WITH HYDROGEN PEROXIDE & DRAIN
    TO WASTE TREATMENT PLANT  OR CALL DISPOSAL CONTRACTOR.

 Disclaimer (provided with this information by the compiling agencies):
 This information is formulated for use by elements of the Department
 of Defense.  The United States of America in no manner whatsoever,
 expressly or implied, warrants this information to be accurate and
 disclaims all liability for its use.  Any person utilizing this
 document should seek competent professional advice to verify and
 assume responsibility for the suitability of this information to their
 particular situation.

*** END OF RECORD ***
Search More   
ALL PAGES On Chemical Property IN THIS GROUP
NAMECAS
COPPER SULFATE, BLE VITROL 7758-99-8
BLUE VITRIOL 7758-99-8
COPPER SULFATE.5H*2O
AMMONIUM THIOCYANATE 1762-95-4
POTASSIUM NITRATE 7757-79-1
DRY MOLY LUBRICANT 6080 75-28-5
74-98-6
75-09-2
7704-34-9
1317-33-5
D173417A
F-152,5430 WHITE TOPCOAT,MFR CODE W-187 71-36-3
13463-67-7
PR-1561 PART A 28182-81-2
822-06-0
1330-20-7
123-86-4
PR-1561 PART B 110-43-0
1330-20-7
123-54-6
P104F318 1336-36-3
DENATURED ALCOHOL 64-17-5
67-56-1
O-E-760,TYPE III 64-17-5
67-56-1
SPECIAL DENATURED ALCOHOL SD-3A 64-17-5
67-56-1
380963 SPRAY A DAY PLUS
N-BUTYL ALCOHOL, ACS 71-36-3
BUTYL ALCOHOL,NORMAL 71-36-3
N-BUTYL ALCOHOL 71-36-3
BUTYL ALCOHOL,NORMAL 71-36-3
W-120 SILICONE PASTE 9016-00-6
1314-13-2
21F408G102 1336-36-3
22F408G102 1336-36-3
TJ6080 1336-36-3
ACRYL 60 7664-41-7
BALAN 2.5G 1861-40-1
00211 DRY FILM VYDAX MOLD REL 116-14-3
76-13-1
75-69-4
75-71-8
T-O-56A,OAKUM,MARINE CLASS 1
BARIUM CYANIDE,TECHNICAL 542-62-1
BARIUM CYANIDE, TECHNICAL 542-62-1
BARIUM CYANIDE 542-62-1
BARIUM CYANIDE 542-62-1
BARIUM CYANIDE 542-62-1
POTASSIUM CHROMATE 7789-00-6
S-410 16893-85-9
SODIUM CARBONATE,MONOHYDRATE
SODIUM CARBONATE MONOHYDRATE 497-19-8
SILVER CYANIDE 506-64-9
SILVER CYANIDE REAGENT 506-64-9
ARGENTOUS CYANIDE 506-64-9
SILVER CYANIDE 506-64-9
SILVER CYANIDE 506-64-9
SILVER CYANIDE 506-64-9
SP99 1336-36-3
DXX-290,DYKEM LAYOUT RED 123-86-4
64-17-5
71-36-3
1103-39-5
9004-70-0
67-63-0
SP-DR670
PC 29-M,PART A 1330-20-7
PC 29-M,PART B 108-65-6
1330-20-7
CONATHANE CE-1155, PART A 1330-20-7
108-65-6
584-84-9
CONATHANE CE-1155,PART B 108-88-3
108-65-6
HUMISEAL 2A64 PART A 108-88-3
108-65-6
141-78-6

Free MSDS Search ( Providing 250,000+ Material Properties )
Chemcas.com| Ads link:todaystock.net