===================== Product Identification =====================
MSDS NAME:CA-200SL CATALYST
NIIN:00N073606
MSDS Number: CCNYG
=== Responsible Party ===
Company:JP TECHNOLOGIES INC
Address:1430 COOLEY COURT
City:SAN BERNARDINO
State:CA
ZIP:92408
Country:US
Info Phone Num:909-799-8000
Emergency Phone Num:800-535-5053
CAGE:JO205
=== Contractor Identification ===
Company:JP TECHNOLOGIES INC
Box:UNKNOW
CAGE:02YS5
Company:JP TECHNOLOGIES INC
Address:42 NORTH BENSON AVENUE
Box:City:UPLAND
State:CA
ZIP:91786
Country:US
Phone:909-946-1000
CAGE:JO205
============= Composition/Information on Ingredients =============
Name:ACETONE (SARA 313) (CERCLA)
CAS:67-64-1
RTECS #:AL3150000
Fraction by Wt: 20%
OSHA PEL:1000 PPM
ACGIH TLV:750PPM/1000STEL
EPA Rpt Qty:5000 LBS
DOT Rpt Qty:5000 LBS
Name:HYDROQUINONE (SARA 302/313) (CERCLA)
CAS:123-31-9
RTECS #:MX3500000
Fraction by Wt: 0.10%
OSHA PEL:2 MG/M3
ACGIH TLV:2 MG/M3
EPA Rpt Qty:1 LB
DOT Rpt Qty:1 LB
Name:ETHANE,1,1,2-TRICHLORO-1,2,2-TRIFLUORO-; (FREON 113) (SARA
313)
CAS:76-13-1
RTECS #:KJ4000000
Fraction by Wt: 80%
OSHA PEL:1000 PPM
ACGIH TLV:1000PPM/1250STEL
Ozone Depleting Chemical:1
Name:NON-HAZARDOUS INGREDIENTS (CONSISTING OF INGREDIENT 5)
Fraction by Wt: 0.01%
OSHA PEL:N/K
ACGIH TLV:N/K
Name:BLUE DYE COMPONENT; (BLUE DYE)
CAS:17354-14-2
OSHA PEL:N/K
ACGIH TLV:N/K
===================== Hazards Identification =====================
LD50 LC50 Mixture:NONE SPECIFIED BY MANUFACTURER.
Routes of Entry: Inhalation:YES Skin:YES Ingestion:YES
Reports of Carcinogenicity:NTP:NO IARC:NO OSHA:NO
Health Hazards Acute and Chronic:ACUTE & CHRONIC:NO DATA AVAIL. SKIN &
EYE CONT:MAY CAUSE IRRIT ON PRLNGD/RPTD CONT. SIGNS &
SYMPS:EXCESSIVE INHAL CAN CAUSE RESP IRRIT, DIZZ, NAUS, POSS
UNCON/ASPHY. OTHER INFO:IN MFR'S BEST TECHNICAL JUDGEMENT,
W/PROPER PRECS, DESIGNATED END USE OF PROD TO PREMOTE BONDING USING
CYANOACRYLATE "INSTANT"(EFTS OF OVEREXP)
Explanation of Carcinogenicity:NOT RELEVANT
Effects of Overexposure:HLTH HAZS:GLUES DOES NOT POSE CONCERNED HAZ AS
IN BULK MFRING. CHLOROFLUOROCARBON (CFC) MATLS HAVE PRDCED SENSIT
OF MYOCARDIUM TO EPINEPHRNE IN LAB ANIMALS & COULD HAVE SIMILAR EFT
IN HUMANS. ADRENOMI METICS (I.E., EPINEPHRINE) MAY BE
CONTRA-INDICATED EXCEPT FOR LIFE-SUSTAINING USES IN HUMANS
ACUTELY/CHRONICALLY(SUPDAT)
Medical Cond Aggravated by Exposure:PROLONGED EXPOSURE ON SKIN WILL
REMOVE FATTY OIL OF THE SKIN CREATING SKIN DRYNESS THAT CAN LEAD TO
MILD IRRITATION.
======================= First Aid Measures =======================
First Aid:SEEK MEDICAL ASSISTANCE FOR FURTHER TREATMENT, OBSERVATION
AND SUPPORT IF NECESSARY. EYE CONTACT:FLUSH THOROUGHLY W/WATER FOR
AT LST 15 MIN. NON IRRIT. CALL MD IF NEC. SKIN CONT:WASH W/SOAP &
WATER. R EMOVE CONTAM CLTHG & WASH BEFORE REUSE.INHAL:MOVE TO FRESH
AIR. IF SYMPTOMS PERSIST, CALL MD. INGEST:DO NOT INDUCE VOMIT. GIVE
LG QTY OF WATER/MILK. DO NOT GIVE FLUIDS TO AN UNCON PERSON. CALL
MD.
===================== Fire Fighting Measures =====================
Flash Point:54.0F,12.2C
Extinguishing Media:WATER SPRAY, CO*2, FOAM, DRY CHEMICAL.
Fire Fighting Procedures:WEAR NIOSH APPROVED PRESSURE DEMAND SCBA &
FULL PROTECTIVE EQUIPMENT .
Unusual Fire/Explosion Hazard:MAY PRODUCE HAZARDOUS FUMES OR HAZARDOUS
DECOMPOSITION PRODUCTS. THERMAL DECOMPOSITION PRODUCTS MAY INCLUDE
FLUORIDES, CHLORIDES AND PHOSGENE .
================== Accidental Release Measures ==================
Spill Release Procedures:ADD DRY MATERIAL TO ABSORB SPILL, USING
RECOMMENDED PROTECTIVE EQUIPMENT.
Neutralizing Agent:NONE SPECIFIED BY MANUFACTURER.
====================== Handling and Storage ======================
Handling and Storage Precautions:KEEP CONTAINERS TIGHTLY CLOSED WHEN
NOT IN USE. STORE IN A DRY LOCATION.
Other Precautions:STORE AWAY FROM HEAT AND DIRECT SUNLIGHT. NO SMOKING
IN AREA OF USE. DO NOT USE IN GENERAL VICINITY OF ARC WELDING, OPEN
FLAMES OR HOT SURFACES. HEAT AND/OR UV RADIATION MAY CAUSE THE
FORMATION OF CHL ORIDES, FLUORIDES OR PHOSGENE .
============= Exposure Controls/Personal Protection =============
Respiratory Protection:NONE NEEDED USING LOCAL EXHAUST (NIOSH APPROVED
ORGANIC RESPIRATOR).
Ventilation:LOCAL EXHAUST.
Protective Gloves:POLYETHYLENE GLOVES.
Eye Protection:ANSI APPROVED CHEM WORKERS GOGGS .
Other Protective Equipment:ANSI APPROVED EMERGENCY EYE WASH AND DELUGE
SHOWER . LAB COAT AND/OR APRON.
Work Hygienic Practices:USE GOOD INDUSTRIAL HYGIENE PRACTICES.
Supplemental Safety and Health
% VOLAT:100 @ 70F. EFTS OF OVEREXP:EXPOSED TO CFCS .
================== Physical/Chemical Properties ==================
Boiling Pt:B.P. Text:110F,43C
Vapor Pres:HVR/AIR
Vapor Density:2.6
Spec Gravity:1.4 (H*2O=1)
Solubility in Water:SLIGHT-0.1-1%
Appearance and Odor:CLEAR LIQUID WITH BLUE TINT. SLIGHT ETHER ODOR.
Percent Volatiles by Volume:SUPDAT
================= Stability and Reactivity Data =================
Stability Indicator/Materials to Avoid:YES
DO NOT MIX WITH OTHER CHEMICALS OR STRONG OXIDIZERS.
Stability Condition to Avoid:NONE SPECIFIED BY MANUFACTURER.
Hazardous Decomposition Products:CARBON MONOXIDE. CHLORIDES, FLUORIDES
AND PHOSGENE .
==================== Disposal Considerations ====================
Waste Disposal Methods:DISPOSAL MUST BE I/A/W FEDERAL, STATE & LOCAL
REGULATIONS . THIS PRODUCT, IF DISPOSED AS SHIPPED, IS NOT A
HAZARDOUS WASTE AS SPECIFIED IN 40 CFR 261. CONSULT STATE OR LOCAL
OFFICIALS FOR PROPER DISPOSAL METHOD.
Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.
*** END OF RECORD *** |
|