===================== Product Identification =====================
MSDS NAME:GENESOLV 2000
NIIN:00D005707
MSDS Number: CCVNF
=== Responsible Party ===
Company:ALLIED-SIGNAL INC
Address:101 COLUMBIA RD
Box:1053
City:MORRISTOWN
State:NJ
ZIP:07962
Country:US
Info Phone Num:800-631-8138
Emergency Phone Num:800-631-8138
Preparer's Name:PRODUCT SAFETY DEPARTMENT
CAGE:0B7T5
=== Contractor Identification ===
Company:ALLIED-SIGNAL INC
Address:101 COLUMBIA RD
Box:1053
City:MORRISTOWN
State:NJ
ZIP:07962-1053
Country:US
Phone:201-455-4157/201-455-2000
CAGE:05VM8
Company:BALKAMP INC
Address:2601 S HOLT ROAD
Box:City:INDIANAPOLIS
State:IN
ZIP:46241
Country:US
Phone:317-244-7241
CAGE:70842
Company:HONEYWELL INTL INC
Address:101 COLUMBIA RD
Box:City:MORRISTOWN
State:NJ
ZIP:07960
Country:US
Phone:201-455-2000/800-707-4555
CAGE:0B7T5
Company:NAPA, A DIVISION OF LINCOLN AUTOMOTIVE
Address:ONE LINCOLN WAY
Box:City:ST. LOUIS
State:MO
ZIP:63120-1578
Country:US
Phone:414-255-5520
CAGE:050Q3
============= Composition/Information on Ingredients =============
Name:1,1-DICHLORO-1-FLUOROETHANE (SARA 313)
CAS:1717-00-6
RTECS #:KI0997000
Fraction by Wt: 100%
Other REC Limits:NONE RECOMMENDED
Ozone Depleting Chemical:2
===================== Hazards Identification =====================
LD50 LC50 Mixture:ORAL LD50 (RAT) IS >5000 MG/KG
Routes of Entry: Inhalation:YES Skin:NO Ingestion:NO
Reports of Carcinogenicity:NTP:NO IARC:NO OSHA:NO
Health Hazards Acute and Chronic:ACUTE: EYE CONTACT MAY CAUSE
IRRITATION, CONJUNCTIVITIS. PROLONGED SKIN CONTACT MAY CAUSE
IRRITATION/DEFATTING. INHALATION MAY CAUSE CNS EFFECTS INCLUDING
CNS DEPRESSION & CARDIAC ARRYTHMIAS; SUFFOCAT ION. INGESTION MAY
CAUSE GI DISCOMFORT;SOME OF THE SAME EFFECTS AS INHALATION.
CHRONIC: UNKNOWN.
Explanation of Carcinogenicity:NO INGREDIENT OF A CONCENTRATION OF 0.1%
OR GREATER IS LISTED AS A CARCINOGEN OR SUSPECTED CARCINOGEN.
Effects of Overexposure:EYES-IRRITATION, CONJUNCTIVITIS. SKIN-
DEFATTING, IRRITATION. INHALED-CNS DEPRESSION, CARDIAC ARRYTHMIAS.
INGESTED-GI DISCOMFORT.
Medical Cond Aggravated by Exposure:NONE SPECIFIED BY MANUFACTURER.
======================= First Aid Measures =======================
First Aid:IN ALL CASES GET MEDICAL ATTN.EYES-FLUSH WITH WATER FOR 15
MINUTES,LIFT LIDS.SKIN-REMOVE CONTAMINATED CLOTHES.WASH W/MILD SOAP
& WATER.INHALED-REMOVE TO FRESH AIR.GIVE OXYGEN OR ARTIFICIAL
RESPIRATION AS NEEDED.INGESTED-DO NOT INDUCE VOMITING!DO NOT GIVE
STIMULANTS!TAKE IMMEDIATELY TO HOSPITAL.NOTE:BECAUSE OF CARDIAC
ARRYTHMIAS, GIVE CATECHOLAMINES ONLY IF NEEDED FOR EMERGENCY LIFE
SUPPORT.
===================== Fire Fighting Measures =====================
Flash Point Method:TOC
Flash Point:NONE
Autoignition Temp:Autoignition Temp Text:550C
Lower Limits:17.7
Upper Limits:7.6
Extinguishing Media:USE MEDIA APPROPRIATE FOR SURROUNDING FIRE.
Fire Fighting Procedures:WEAR SELF-CONTAINED BREATHING APPARATUS AND
FULL FIRE FIGHTER'S PROTECTIVE GEAR. USE WATER TO COOL FIRE EXPOSED
CONTAINERS.
Unusual Fire/Explosion Hazard:PRODUCT WILL DEOMPOSE AT TEMPERATURES
ABOVE 250C. SOLVENT VAPORS WHEN PRESENT IN THE FLAMMABLE RANGE MAY
CAUSE EXOTHERMIC REACTIONS/EXPLOSIONS IF FLAMES PRESENT
================== Accidental Release Measures ==================
Spill Release Procedures:WEAR PROPER PERSONAL PROTECTIVE GEAR. EVACUATE
& VENTILATE AREA. ELIMINATE ALL SOURCES OF IGNITION. KEEP UPWIND.
DIKE TO CONTAIN. PREVENT CONTAMINATION OF GROUND & SURFACE WATERS.
RECOVER/ ABSORB MATE RIAL, PLACE IN CONTAINER FOR LATER DISPSOAL.
Neutralizing Agent:NONE SPECIFIED BY MANUFACTURER.
====================== Handling and Storage ======================
Handling and Storage Precautions:KEEP CONTAINER CLOSED WHEN NOT IN USE.
DO NOT STORE IN OPEN, UNLABELED OR MISLABELED CONTAINERS. STORE IN
A COOL, DRY PLACE OF LOW FIRE RISK.
Other Precautions:STORAGE IN SUBSURFACE LOCATIONS SHOULD BE AVOIDED.
PROTECT CONTAINER FROM PHYSICAL DAMAGE.IF DRUM TEMPERATURE EXCEEDS
BOILING POINT, COOL DRUM BEFORE OPENING.
============= Exposure Controls/Personal Protection =============
Respiratory Protection:NONE NORMALLY REQUIRED. USE NIOSH APPROVED SELF-
CONTAINED BREATHING APPARATUS FOR EMERGENCIES & IN SITUATIONS WHERE
AIR MAY BE DISPLACED BY VAPORS.
Ventilation:LOCAL EXHAUST AT FILLING ZONES & WHERE LEAKAGE LIKELY.
GENERAL/MECHANICAL VENTILATION IN STORAGE AREAS.
Protective Gloves:MYLAR COATED DURAFAB, PVA OR NEOPRENE.
Eye Protection:SAFETY GLASSES/CHEMICAL SPLASH GOGGLES.
Other Protective Equipment:FULL PROTECTIVE CLOTHING IF THERE IS
PROLONGED OR REPEATED CONTACT OF LIQUID WITH SKIN. EYE WASH/SAFETY
SHOWER.
Work Hygienic Practices:WASH HANDS AFTER HANDLING AND BEFORE EATING,
DRINKING, OR SMOKING. LAUNDER CONTAMINATED CLOTHES BEFORE REUSE.
Supplemental Safety and Health
================== Physical/Chemical Properties ==================
HCC:T6
Boiling Pt:B.P. Text:89.6F,32.0C
Decomp Temp:Decomp Text:482F,250C
Vapor Pres:518
Vapor Density:4.1
Spec Gravity:1.24
pH:7
Evaporation Rate & Reference:>1 (ETHER=1)
Solubility in Water:SLIGHT
Appearance and Odor:COLORLESS LIQUID; ETHEREAL & FAINT SWEETISH ODOR.
Percent Volatiles by Volume:100
================= Stability and Reactivity Data =================
Stability Indicator/Materials to Avoid:YES
STRONG ACIDS & ALKALIS, REACTIVE METALS, STRONG OXIDIZING AGENTS; SOME
DESSICANTS.
Stability Condition to Avoid:AVOID SOURCES OF IGNITION SUCH AS SPARKS,
HOT SPOTS, WELDING, FLAMES, & CIGARETTES.
Hazardous Decomposition Products:HYDROCHLORIC & HYDROFLUORIC ACIDS,
CARBONYL HALIDES SUCH AS PHOSGENE.
Conditions to Avoid Polymerization:WILL NOT OCCUR.
==================== Disposal Considerations ====================
Waste Disposal Methods:DO NOT FLUSH TO SEWER! UNUSED PRODUCT IS NOT
CONSIDERED A RCRA WASTE; HOWEVER PRODUCT SHOULD BE PROPERLY
DISPOSED OF. SPENT SOLVENT IS HAZWASTE CODE F002 FOR SOLVENT
APPLICATIONS; F001 FOR DEGREASING APPLICATIONS.
Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.
*** END OF RECORD *** |
|