===================== Product Identification =====================
MSDS NAME:THERMOMETER, MIL-T-15942; 415F-ROOL-C25Y
NIIN:00-254-6610
MSDS Number: BDPBP
=== Responsible Party ===
Company:WEKSLER INSTRUMENTS CORP.
Address:80 MILL RD
City:FREEPORT,LONG ISLAND
State:NY
ZIP:11520-4616
Country:US
Info Phone Num:516-623-0100
Emergency Phone Num:516-623-0100
CAGE:64467
=== Contractor Identification ===
Company:WEKSLERIGLASS THERMOMETER CORP
Address:80 MILL ROAD
Box:City:FREEPORT
State:NY
ZIP:11520
Country:US
Phone:516-623-0100
CAGE:64467
============= Composition/Information on Ingredients =============
Name:MERCURY (SARA III)
CAS:7439-97-6
RTECS #:OV4550000
Fraction by Wt: 100%
OSHA PEL:S, C, 0.1 MG/M3
ACGIH TLV:S, 0.05 MG/M3; 9192
EPA Rpt Qty:1 LB
DOT Rpt Qty:1 LB
===================== Hazards Identification =====================
LD50 LC50 Mixture:TCLO-MAN 4430 UG/CUM 8HR
Routes of Entry: Inhalation:YES Skin:YES Ingestion:YES
Reports of Carcinogenicity:NTP:NO IARC:NO OSHA:NO
Health Hazards Acute and Chronic:ACUTE MERCURY POISONING IS RARE. MOST
OFTEN IT IS THE RESULT OF CHRONIC INHALATION. MERCURY MAY ALSO BE
ABSORBED THROUGH THE SKIN.
Effects of Overexposure:SIGNS OF MERCURY POISONING ARE METALLIC
TASTE,EXCESSIVE SALIVATION,IRRITABILITY AND TREMORS. SKIN CONTACT
MAY CAUSE DERMATITIS AND/OR ALLERGIC SENSITIZATION.
Medical Cond Aggravated by Exposure:TUBERCULOSIS,KIDNEY
DISEASE,ALCOHOLISM
======================= First Aid Measures =======================
First Aid:REMOVE FROM EXPOSURE. CONSULT A PHYSICIAN.
===================== Fire Fighting Measures =====================
Flash Point:NONE
Extinguishing Media:USE MEDIA TO EXTINGUISH SURROUNDING FIRE
Fire Fighting Procedures:USE SELF CONTAINED BREATHING APPARATUS.
Unusual Fire/Explosion Hazard:IS NON-FLAMMABLE BUT EVAPORATES RAPIDLY
WHEN HEATED CREATING TOXIC FUMES.
================== Accidental Release Measures ==================
Spill Release Procedures:VACUUM SPILLS WITH VACUUM HAVING A FILTERED
EXHAUST. DO NOT SWEEP. WASH AREA WITH SOAP AND WATER.
Neutralizing Agent:NONE
====================== Handling and Storage ======================
Handling and Storage Precautions:HANDLE AND STORE THERMOMETERS
CAREFULLY. AVOID BREAKAGE AND RELEASE OF MERCURY.
============= Exposure Controls/Personal Protection =============
Respiratory Protection:NIOSH APPROVED RESPIRATOR. TYPE DEPENDS ON LEVEL
OF EXPOSURE.
Ventilation:SUFFICIENT TO MAINTAIN EXPOSURE BELOW TLV.
Protective Gloves:RUBBER/PLASTIC
Eye Protection:SAFETY GLASSES
Other Protective Equipment:CLOTHING NECESSARY TO PREVENT SKIN CONTACT.
Work Hygienic Practices:KEEP FOOD STUFF STORED AWAY FROM MERCURY.
Supplemental Safety and Health
THERMOMETER CONTAINS APPROXIMATELY 1 ML OF MERCURY. THERE IS NO HAZARD
AS LONG AS THE UNIT IS INTACT.
================== Physical/Chemical Properties ==================
HCC:Z2
Boiling Pt:=357.8C, 676.F
Melt/Freeze Pt:=-38.7C, -38.F
Vapor Pres:0.0019
Vapor Density:1.015
Spec Gravity:13.59
Evaporation Rate & Reference:<1 BUAC
Appearance and Odor:SILVER METALLIC LIQUID, NO ODOR
================= Stability and Reactivity Data =================
Stability Indicator/Materials to Avoid:YES
GOLD,SILVER,AMMONIA
Stability Condition to Avoid:MERCURY READILY FORMS AMALGAMS AND REACTS
TO FORM SOME UNSTABLE COMPOUNDS.
Hazardous Decomposition Products:NONE
==================== Disposal Considerations ====================
Waste Disposal Methods:DO NOT PLACE IN GARBAGE OR INCINERATOR OR FLUSH
TO SEWER. REMOVE MERCURY OR MERCURY CONTAMINATED MATERIALS TO
DISPOSAL SITE I/A/W FEDERAL, STATE, LOCAL REGULATIONS.
Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.
*** END OF RECORD *** |
|