===================== Product Identification =====================
MSDS NAME:CSA,CHLOROSULFURIC ACID
NIIN:00-281-8532
MSDS Number: BDTDG
=== Responsible Party ===
Company:E. I. DUPONT DE NEMOURS & CO,INC.
Address:1007 MARKET STREET
Box:1635
City:WILMINGTON
State:DE
ZIP:19899
Country:US
Info Phone Num:800-441-7515
Emergency Phone Num:800-441-7515
CAGE:73925
=== Contractor Identification ===
Company:DU PONT E I DE NEMOURS AND CO INC PETROCHEMICALS DEPT
Address:1251 BRANDYWINE BLDG
Box:City:WILMINGTON
State:DE
ZIP:19898
Phone:302-773-5676
CAGE:73925
Company:E.I. DUPONT DE NEMOURS & CO
Address:1007 MARKET STREET
Box:City:WILMINGTON
State:DE
ZIP:19898
Country:US
Phone:800-441-7515;800-441-9442
CAGE:18873
============= Composition/Information on Ingredients =============
Name:CHLOROSULFONIC ACID (SARA III)
CAS:7790-94-5
RTECS #:FX5730000
Fraction by Wt: 99.4%
===================== Hazards Identification =====================
Effects of Overexposure:EYES/SKIN:CAUSES SEVERE BURNS.HARMFUL IF
INHALED.CHRONIC EXPOSURE TO VAP/MIST MAY DAMAG TEETH,RESPIR
======================= First Aid Measures =======================
First Aid:SKIN:WASH W.SOAP & H*2O. EYES:FLUSH W. H*2O. INGESTED:DON'T
INDUCE VOMITING. INHALED:REMOVE TO FRESH AIR. GIVE CPR/OXYGEN IF
NEED. KEEP WARM & QUIET. REMOVE CONTAMINATED CLOTHING. NEVER GIVE
ANYTHING BY MOUTH TO UNCONSCIOUS PERSON.
===================== Fire Fighting Measures =====================
Extinguishing Media:CO*2, FOAM, DRY CHEM.
Fire Fighting Procedures:USE H*20 TO COOL EXPD CONTRS. USE SCBA & FULL
PROT.CLTHG.
Unusual Fire/Explosion Hazard:REACTS VIOLENTLY W WATER.NO WATER INSIDE
CONTAINER.COOL CONTAINERS EXPOSED TO FIRE WITH WATER.
================== Accidental Release Measures ==================
Spill Release Procedures:ELIMINATE IGNITION SOURCES. STOP LEAK W/O
RISK. EVACUATE AREA. SM SPILL:ABSORB WITH INERT ABSORBENT,FLUSH
AREA WITH WATER. LG SPILL:NEUTRALIZE WITH SODA ASH. FLUSH
NEUTRALIZED SOLUTION TO SEWER IN ACC ORDANCE WITH INTERNATIONAL
FED,STA, & LOCAL REGS.
====================== Handling and Storage ======================
Handling and Storage Precautions:KEEP IN WELL-VENTED AREA,AVOID
IGNITION SOURCES.KEEP CONTR CLOSED.NO WATER INSIDE CONTR.NO PRESS
TO EMPTY.DO NOT RINSE/REUSE CONTAINER.
Other Precautions:USE ACID SUIT WITH BRTHNG AIR SUPPLY.
============= Exposure Controls/Personal Protection =============
Respiratory Protection:SCBA IN FIRE,OTHERWISE CHEM CARTR RESPIR.
Ventilation:PROVIDE MECHAN(GEN/LOCAL EXHAUST)VENT TO MAINTN
| |