===================== Product Identification =====================
MSDS NAME:26R253, VERSATEC CLEAR DISPERSANT FOR V-80, (SUPDAT)
NIIN:00N085890
MSDS Number: CHDCJ
=== Responsible Party ===
Company:XEROX CORP
Address:100 CLINTON AVE S
City:ROCHESTER
State:NY
ZIP:14644
Country:US
Info Phone Num:800-828-6571
Emergency Phone Num:716-422-2177; 716-422-1230
CAGE:0E6G9
=== Contractor Identification ===
Company:XEROX CORP
Address:300 MAIN ST NO 27C
City:EAST ROCHESTER
State:NY
ZIP:14645
Country:US
Phone:800-828-6571; 800-351-2024
CAGE:0E6G9
Company:XEROX CORPORATION
Address:100 CLINTON AVE SOUTH
Box:City:ROCHESTER
State:NY
ZIP:14644-1877
Country:US
Phone:800-828-6571/716-422-2177
CAGE:26921
============= Composition/Information on Ingredients =============
Name:NAPHTHOL SPIRITS; (ISOPARAFFINIC HYDROCARBON SOLVENT)
CAS:64742-48-9
Fraction by Wt: 100%
OSHA PEL:N/K
ACGIH TLV:N/K
===================== Hazards Identification =====================
LD50 LC50 Mixture:LD50: (ORAL, RAT) >10 G/KG
Routes of Entry: Inhalation:YES Skin:YES Ingestion:YES
Reports of Carcinogenicity:NTP:NO IARC:NO OSHA:NO
Health Hazards Acute and Chronic:HIGH VAPOR CONCENTRATIONS (>1000 PPM)
ARE IRRITATING TO THE EYES AND RESPIRATORY TRACT AND MAY CAUSE
HEADACHES, DIZZINESS, ANESTHESIA, DROWSINESS, UNCONSCIOUSNESS AND
OTHER CENTRAL NERVOUS SYSTEM EFFE CTS, INCLUDING FATALITY.
ADDITIONAL INFO: ISOPARAFFINIC HYDROCARBON SOLVENT HAS A LOW ORDER
OF ACUTE (EFTS OF OVEREXP)
Explanation of Carcinogenicity:NOT RELEVANT
Effects of Overexposure:HLTH HAZ: ORAL AND DERMAL TOXICITY, BUT MINUTE
AMOUNTS ASPIRATED INTO THE LUNGS DURING INGESTION OR VOMITING MAY
CAUSE MILD TO SEVERE PULMONARY INJURY, INCLUDING FATALITY.
Medical Cond Aggravated by Exposure:SKIN CONTACT MAY AGGRAVATE AN
EXISTING DERMATITIS.
======================= First Aid Measures =======================
Eyes: FLUSH WITH WATER FOR AT LEAST 15 MINUTES. IF IRRITATION
PERSISTS, CALL MD. SKIN: WASH WITH SOAP AND WATER. IF SKIN IS
BROKEN, CALL MD. INHALATION: REMOVE FROM EXPOSURE. INGESTION: DO
NOT INDUCE VOMITING. CALL MD IMMEDIATELY.
===================== Fire Fighting Measures =====================
Flash Point Method:TCC
Flash Point:105F,41C
Lower Limits:0.8%
Upper Limits:7.0%
Extinguishing Media:FOAM, DRY CHEMICAL, CARBON DIOXIDE, WATER FOG OR
SPRAY.
Fire Fighting Procedures:USE NIOSH APPROVED SCBA AND FULL PROTECTIVE
EQUIPMENT . COOL EXPOSED CONTAINERS WITH WATER SPRAY. AVOID
BREATHING VAPOR OR FUMES.
Unusual Fire/Explosion Hazard:DO NOT MIX OR STORE WITH STRONG OXIDANTS
LIKE LIQUID CHLORINE OR CONCENTRATED OXYGEN.
================== Accidental Release Measures ==================
Spill Release Procedures:REMOVE IGNITION SOURCES. RECOVER FREE LIQUID,
USING AN ABSORBENT MATERIAL (VERMICULITE, FIRE RETARDANT, SAWDUST,
ETC).
Neutralizing Agent:NONE SPECIFIED BY MANUFACTURER.
====================== Handling and Storage ======================
Handling and Storage Precautions:KEEP CONTAINERS CLOSED WHEN NOT IN
USE. DO NOT HANDLE OR STORE NEAR HEAT, SPARKS, FLAME OR STRONG
OXIDANTS.
Other Precautions:ADEQUATE VENTILATION REQUIRED (EQUIVALENT TO
OUTDOORS).
============= Exposure Controls/Personal Protection =============
Respiratory Protection:NONE REQUIRED WHEN USED AS INTENDED IN XEROX
PRODUCTS. USE NIOSH APPROVED RESPIRATOR APPROPRIATE FOR EXPOSURE OF
CONCERN .
Ventilation:NONE SPECIFIED BY MANUFACTURER.
Protective Gloves:IMPERVIOUS GLOVES .
Eye Protection:ANSI APPRVD CHEM WORKERS GOGGLES .
Other Protective Equipment:ANSI APPRVD EYE WASH & DELUGE SHOWER . CHEM
RESIST APRON/OTHER CLTHG IF NEEDED TO AVOID RPTD & PRLNGD SKIN
CNTCT.
Work Hygienic Practices:NONE SPECIFIED BY MANUFACTURER.
Supplemental Safety and Health
MFR'S TRADE NAME/PART NO: 8000 SERIES, 800, 900, 1100, 1200, 1600,
2000, 3000, 7000, 8500.
================== Physical/Chemical Properties ==================
Boiling Pt:B.P. Text:>320F,>160C
Vapor Pres:<10 @ 25C
Vapor Density:5.0
Spec Gravity:0.77 (H*2O=1)
VOC Pounds/Gallon:750
Evaporation Rate & Reference:0.3 (N-BUTYL ACETATE=1)
Solubility in Water:NEGLIGIBLE
Appearance and Odor:WATER WHITE LIQUID; MILD ODOR.
================= Stability and Reactivity Data =================
Stability Indicator/Materials to Avoid:YES
STRONG OXIDANTS LIKE LIQUID CHLORINE, CONCENTRATED OXYGEN, SODIUM OR
CALCIUM HYPOCHLORITE.
Stability Condition to Avoid:NONE SPECIFIED BY MANUFACTURER.
Hazardous Decomposition Products:FUMES, SMOKE AND CARBON MONOXIDE IN
THE CASE OF INCOMPLETE COMBUSTION.
==================== Disposal Considerations ====================
Waste Disposal Methods:THE RESIDUAL CLEAR DISPERSANT MAY BE CLASSIFIED
AS AN IGNITABLE HAZARDOUS WASTE UNDER FEDERAL AND/OR STATE
REGULATIONS AND SHOULD BE DISPOSED OF AT AN APPROVED DISPOSAL SITE
OR FACILITY IN ACCORDANCE WITH FEDERAL, STATE AND LOCAL
REGULATIONS.
======================= Other Information =======================
Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.
*** END OF RECORD *** |
|