iron; (steel powder) (carrier) toner (consisting of ings 3 - 6) styrene/acrylate polymer carbon black pyridinium, 1-hexadecyl-, chloride; (quaternary ammonium dimethyldioctadecylammonium methyl sulfate; (quaternary supp data:functionally suitable for xerox equipment.
===================== Product Identification =====================
MSDS NAME:5R327, DEVELOPER DOCUPRINT 390, 1075, 1090, (SUPDAT)
NIIN:00N085936
MSDS Number: CHDFH
=== Responsible Party ===
Company:XEROX CORP
Address:100 CLINTON AVE S
City:ROCHESTER
State:NY
ZIP:14644
Country:US
Info Phone Num:800-828-6571
Emergency Phone Num:716-422-2177; 716-422-1230
CAGE:0E6G9
=== Contractor Identification ===
Company:XEROX CORP
Address:300 MAIN ST NO 27C
City:EAST ROCHESTER
State:NY
ZIP:14645
Country:US
Phone:800-828-6571; 800-351-2024
CAGE:0E6G9
Company:XEROX CORPORATION
Address:100 CLINTON AVE SOUTH
Box:City:ROCHESTER
State:NY
ZIP:14644-1877
Country:US
Phone:800-828-6571/716-422-2177
CAGE:26921
============= Composition/Information on Ingredients =============
Name:IRON; (STEEL POWDER) (CARRIER)
CAS:7439-89-6
RTECS #:NO4565500
Fraction by Wt: 95-100%
OSHA PEL:N/K
ACGIH TLV:N/K
Name:TONER (CONSISTING OF INGS 3 - 6)
RTECS #:9999999ZZ
Fraction by Wt: <5%
OSHA PEL:N/K
ACGIH TLV:N/K
Name:STYRENE/ACRYLATE POLYMER
CAS:25213-39-2
Fraction by Wt: >90%
OSHA PEL:N/K
ACGIH TLV:N/K
Name:CARBON BLACK
CAS:1333-86-4
RTECS #:FF5800000
Fraction by Wt: 5-10%
OSHA PEL:3.5 MG/M3
ACGIH TLV:3.5 MG/M3
Name:PYRIDINIUM, 1-HEXADECYL-, CHLORIDE; (QUATERNARY AMMONIUM
SALT)
CAS:123-03-5
RTECS #:UU4900000
Fraction by Wt: <2%
OSHA PEL:3.5 MG/M3
ACGIH TLV:3.5 MG/M3
Name:DIMETHYLDIOCTADECYLAMMONIUM METHYL SULFATE; (QUATERNARY
AMMONIUM SALT)
CAS:3843-16-1
Fraction by Wt: <2%
OSHA PEL:N/K
ACGIH TLV:N/K
Name:SUPP DATA:FUNCTIONALLY SUITABLE FOR XEROX EQUIPMENT.
RTECS #:9999999ZZ
===================== Hazards Identification =====================
LD50 LC50 Mixture:LD50:(ORAL,RAT) >10 G/KG.
Routes of Entry: Inhalation:YES Skin:NO Ingestion:NO
Reports of Carcinogenicity:NTP:NO IARC:YES OSHA:NO
Health Hazards Acute and Chronic:MINIMAL RESPIRATORY TRACT IRRITATION
MAY OCCUR AS WITH EXPOSURE TO LARGE AMOUNTS OF ANY NON-TOXIC DUST.
TOXICOLOGY INFORMATION:RSLTS OBTAINED FROM XEROX SPONSORED CHRONIC
TONER INHAL STUDY, DEMONSTRAT ED NO LUNG CHANGE IN RATS FOR LOWEST
(1MG/M3) EXPOS LEVEL (I.E., LEVEL MOST RELEVANT TO POTNTL HUMAN
(EFTS OF OVEREXP)
Explanation of Carcinogenicity:CARBON BLACK:IARC MONOGRAPHS, VOL 65, PG
149, 1996:GROUP 2B.
Effects of Overexposure:HLTH HAZ:EXPOS). A VERY SLIGHT DEGREE OF
FIBROSIS WAS NOTED IN 25% OF ANIMALS AT MIDDLE (4 MG/M3) EXPOS
LEVEL, WHILE A SLIGHT DEGREE OF FIBROSIS WAS NOTED IN ALL ANIMALS
AT HIGHEST (16 MG/M3) EXPOS LE VEL. THESE FINDINGS ARE ATTRIBUTED
TO "LUNG OVERLOADING", A GENERIC RESPONSE TO EXCESSIVE AMTS OF ANY
DUST (SUPP DATA)
Medical Cond Aggravated by Exposure:NONE WHEN USED AS DESCRIBED BY
PRODUCT LITERATURE.
======================= First Aid Measures =======================
Eyes:FLUSH W/WATER FOR AT LEAST 15 MINUTES. SKIN:WASH W/SOAP
& WATER. INHAL:REMOVE FROM EXPOSURE. INGEST:DILUTE STOMACH CONTENTS
W/SEVERAL GLASSES OF WATER.
===================== Fire Fighting Measures =====================
Extinguishing Media:WATER, FOAM, DRY CHEMICAL.
Fire Fighting Procedures:USE NIOSH APPROVED SCBA & FULL PROTECTIVE
EQUIPMENT . AVOID INHALATION OF SMOKE.
Unusual Fire/Explosion Hazard:NONE.
================== Accidental Release Measures ==================
Spill Release Procedures:IF SPILLED, SWEEP UP OR VACUUM.
Neutralizing Agent:NONE SPECIFIED BY MANUFACTURER.
====================== Handling and Storage ======================
Handling and Storage Precautions:NONE.
Other Precautions:AVOID PROLONGED INHALATION OF EXCESSIVE DUST.
============= Exposure Controls/Personal Protection =============
Respiratory Protection:FOR USE OTHER THAN NORMAL CUSTOMER-OPERATING
PROCEDURES (SUCH AS IN BULK TONER PROCESSING FACILITIES), NIOSH
APPROVED RESPIRATORS MAY BE REQUIRED. FOR MORE INFORMATION, CONTACT
XEROX.
Ventilation:NONE SPECIFIED BY MANUFACTURER.
Protective Gloves:IMPERVIOUS GLOVES .
Eye Protection:ANSI APPROVED CHEM WORKERS GOGGS .
Other Protective Equipment:EYE WASH FOUNTAIN & DELUGE SHOWER WHICH MEET
ANSI DESIGN CRITERIA .
Work Hygienic Practices:NONE SPECIFIED BY MANUFACTURER.
Supplemental Safety and Health
MFR'S TRADE NAME/PART NO:4050, 4090, 4450, 4530, 4650, 5388, 5892
DOCUTECH MODE 90. EFTS OF OVEREXP:RETAINED IN LUNGS FOR PRLNG
PERIOD. THIS STUDY WAS CONDUCTED USING A SPECIAL TEST TONER TO
COMPLY W/ EPA TESTING PROTOCOL. TEST TONER WAS 10TIMES MORE
RESPIRABLE THAN COMMERCIALLY AVAIL XEROX TONER & WOULD NOT BE (ING
7)
================== Physical/Chemical Properties ==================
Spec Gravity:7 (H*2O=1)
Solubility in Water:NEGLIGIBLE
Appearance and Odor:BLACK GRANULAR; FAINT ODOR.
================= Stability and Reactivity Data =================
Stability Indicator/Materials to Avoid:YES
NONE.
Stability Condition to Avoid:NONE SPECIFIED BY MANUFACTURER.
Hazardous Decomposition Products:PRODUCTS OF COMBUSTION MAY BE TOXIC.
AVOID BREATHING SMOKE.
==================== Disposal Considerations ====================
Waste Disposal Methods:DISP MUST BE I/A/W FED, STATE & LOC REGS . THIS
MATL IS NOT HAZ WASTE ACCORDING TO FED REG 40 CFR 261 WHEN
DISPOSED. STATE & LOC WASTE DISP REQUIREMENTS MAY HOWEVER, BE MORE
RESTRICTIVE. CONSULT W/APPROP STATE & LOC AUTHS FOR SPECIFIC INFO.
Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.
*** END OF RECORD ***