===================== Product Identification =====================
MSDS NAME:H160S HYDROCHLORIC ACID 6.0N
NIIN:00F056470
MSDS Number: CHNCZ
=== Responsible Party ===
Company:SPECTRUM CHEMICAL MFG CORP
Address:14422 S SAN PEDRO STREET
City:GARDENA
State:CA
ZIP:90248-9985
Country:US
Info Phone Num:310-516-8000
Emergency Phone Num:310-516-8000
Preparer's Name:E BRULL
CAGE:63415
=== Contractor Identification ===
Company:SPECTRUM LABORATORY PRODUCTS INC
Address:14422 S SAN PEDRO ST
Box:City:GARDENA
State:CA
ZIP:90248-2027
Country:US
Phone:310-516-8000/FAX: 310-516-9843
CAGE:63415
============= Composition/Information on Ingredients =============
Name:HYDROCHLORIC ACID, HYDROGEN CHLORIDE, MURIATIC ACID
HYDROCHLORIDE
CAS:7647-01-0
RTECS #:MW4025000
Fraction by Wt: 8.1%
Other REC Limits:7 PPM
OSHA PEL:5 PPM
ACGIH TLV:C 11 MG/CUM
EPA Rpt Qty:5000 LBS
DOT Rpt Qty:5000 LBS
Name:WATER
CAS:7732-18-5
RTECS #:ZC0110000
Fraction by Wt: 92.9%
===================== Hazards Identification =====================
Routes of Entry: Inhalation:YES Skin:YES Ingestion:NO
Reports of Carcinogenicity:NTP:NO IARC:NO OSHA:NO
Health Hazards Acute and Chronic:CORROSIVE TO EYES & SKIN. LIQUID/SPRAY
MIST MAY PRODUCE TISSUE DAMAGE TO MUCOUS MEMBRANES OF EYES, MOUTH &
RESPIRATORY TRACT. INHALATION: MAY CAUSE BURNS, RESPIRATORY TRACT
IRRITATION. REPEATED/PROLON GED EXPOSURE CAN PRODUCE TARGET ORGANS
DAMAGE & SEVERE EYE/SKIN IRRITATION.
Explanation of Carcinogenicity:NONE
Effects of Overexposure:IRRITATION, BURNS, COUGHING, CHOKING, SHORTNESS
OF BREATH, ATTACKS OF BRONCHIAL INFECTION
======================= First Aid Measures =======================
Eyes: REMOVE CONTACT LENSES. FLUSH W/RUNNING WATER FOR 15
MINS. KEEP EYELIDS OPEN. DON'T USE AN OINTMENT. SKIN: PLACE UNDER A
DELUGE SHOWER/NEUTRALIZE W/A DILUTE SOLUTION OF SODIUM CARBONATE.
WASH W/R UNNING WATER & NON-ABRASIVE SOAP. INHALATION: REMOVE TO
SAFE AREA, GIVE OXYGEN/CPR IF NEEDED. INGESTION: DON'T INDUCE
VOMITING. IF CONSCIOUS, GIVE WATER/MILK. OBTAIN MEDICAL ATTENTION
IN ALL CASES.
===================== Fire Fighting Measures =====================
Extinguishing Media:NON-FLAMMABLE
================== Accidental Release Measures ==================
Spill Release Procedures:SMALL: DILUTE W/WATER, MOP UP/ABSORB W/INERT
MATERIAL, PLACE IN WASTE DISPOSAL CONTAINER. LARGE: STOP LEAK W/O
RISK. ABSORB W/DRY EARTH/SAND. DON'T GET WATER INSIDE CONTAINER.
DON'T TOUCH MATERIAL. US E WATERSPRAY TO DIVERT VAPOR DRIFT.
(SEE SUPP)
Neutralizing Agent:NEUTRALIZE RESIDUE W/A DILUTE SOLUTION OF SODIUM
CARBONATE
====================== Handling and Storage ======================
Handling and Storage Precautions:STORE IN A METALLIC/COATED FIBREBOARD
DRUM USING A STRONG POLYETHYLENE INNER PACKAGE. KEEP DRY. NEVER ADD
WATER TO THIS PRODUCT. DON'T INGEST.
Other Precautions:KEEP AWAY FROM INCOMPATIBLES AS METALS, ALKALIS &
MOISTURE. DON'T BREATHE GAS, FUMES, VAPOR/GAS. AVOID CONTACT W/SKIN
& EYES. MAY CORRODE METALLIC SURFACES. CORROSIVE MATERIALS SHOULD
BE STORED IN SEP ARATE SAFETY STORAGE CABINET/ROOM.
============= Exposure Controls/Personal Protection =============
Respiratory Protection:USE VAPOR RESPIRATOR, MSHA/NIOSH APPROVED WHEN
VENTILATION IS INADEQUATE. SELF CONTAINED BREATHING APPARATUS.
Ventilation:EXHAUST VENTILATION/OTHER ENGINEERING CONTROLS TO KEEP
AIRBORNE CONCENTRATIONS OF VAPORS
| |