phenol red gentamicin sulfate human serum albumin (albumin colloid)
===================== Product Identification =====================
MSDS NAME:1011 QUINNS SPERM WASHING MEDIUM
NIIN:00F056366
MSDS Number: CHPMP
=== Responsible Party ===
Company:ADVANCED REPRODUCTIVE TECHNOLOGIES INC
Address:944 CALLE AMANECER SUITE L
City:SAN CLEMENTE
State:CA
ZIP:92673
Country:US
Info Phone Num:714-498-7804
Emergency Phone Num:714-498-7804
CAGE:AASDV
=== Contractor Identification ===
Company:ADVANCED REPRODUCTIVE TECHNOLOGIES INC
Address:944 CALLE AMANECER SUITE L
City:SAN CLEMENTE
State:CA
ZIP:92673
Country:US
Phone:714-498-7804
CAGE:AASDV
============= Composition/Information on Ingredients =============
Name:PHENOL RED
CAS:34487-61-1
Name:GENTAMICIN SULFATE
CAS:1405-41-0
RTECS #:LY2625000
Name:HUMAN SERUM ALBUMIN (ALBUMIN COLLOID)
===================== Hazards Identification =====================
Routes of Entry: Inhalation:NO Skin:NO Ingestion:NO
Reports of Carcinogenicity:NTP:NO IARC:NO OSHA:NO
Health Hazards Acute and Chronic:CONTAINS A HUMAN SOURCE MATERIAL.
Explanation of Carcinogenicity:NONE
Effects of Overexposure:CONTAINS A HUMAN SOURCE MATERIAL.
======================= First Aid Measures =======================
Eyes: FLUSH W/COPIOUS AMOUNTS OF WATER. INGESTION: WASH OUT
MOUTH W/WATER IF CONSCIOUS. OBTAIN MEDICAL ATTENTION IN ALL CASES.
===================== Fire Fighting Measures =====================
Extinguishing Media:WATER, CO2/ANY OTHER MEDIA SUITABLE FOR
EXTINGUISHING FIRE.
Fire Fighting Procedures:NONE
Unusual Fire/Explosion Hazard:NON-FLAMMABLE.
================== Accidental Release Measures ==================
Spill Release Procedures:USE ABSORBENT MATERIAL TO MOP UP. WASH AREA
W/WATER.
====================== Handling and Storage ======================
Handling and Storage Precautions:STORE IN COLD ROOM AT 35.6-46.4F.
STORE PRODUCT AT 35.6-46.4F WHEN NOT BEING USED.
Other Precautions:DON'T MOUTH PIPETE. AVOID ANY UNNECESARRY CONTACT
W/SKIN, EYES/MUCOUS MEMBRANES. INDIVIDUALS W/PREVIOUS HISTORY OF
ALLERGY TO ANTIBIOTICS &/ASTHMA, SHOULD AVOID EXPOSURE.
============= Exposure Controls/Personal Protection =============
Respiratory Protection:USE NIOSH/MSHA APPROVED MECHANICAL DUST/MIST
CARTRIDGE RESPIRATOR.
Ventilation:LOCAL EXHAUST: ADEQUATE. MECHANICAL: RECOMMENDED.
Protective Gloves:RUBBER
Eye Protection:CHEMICAL SAFETY GOGGLES
Other Protective Equipment:OVERALLS.
Supplemental Safety and Health
================== Physical/Chemical Properties ==================
Spec Gravity:1
Appearance and Odor:PINK COLOR CLEAR LIQUID
================= Stability and Reactivity Data =================
Stability Indicator/Materials to Avoid:YES
Stability Condition to Avoid:ELEVATED TEMPS >104F
==================== Disposal Considerations ====================
Waste Disposal Methods:DISPOSE OF IN AN APPROVED LANDFILL/INCINERATOR,
IAW/FEDERAL, STATE & LOCAL REGULATIONS.
Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.
*** END OF RECORD ***