===================== Product Identification =====================
MSDS NAME:PHOTORECEPTOR, 13R70, RX: 13R71, XCI: 13R521
Status Code:A
MSDS Number: CKSWN
=== Responsible Party ===
Company:XEROX CORPORATION
City:ROCHESTER
State:NY
ZIP:14644
Country:US
Info Phone Num:800-828-6571
Emergency Phone Num:716-422-2177; 716-422-1230
Resp. Party Other MSDS Num.:C-0360
CAGE:26921
=== Contractor Identification ===
Company:XEROX CORPORATION
Address:100 CLINTON AVE SOUTH
Box:City:ROCHESTER
State:NY
ZIP:14644-1877
Country:US
Phone:800-828-6571/716-422-2177
CAGE:26921
============= Composition/Information on Ingredients =============
Name:POLYCARBONATE (MFR CAS #25134-45-6)
CAS:24936-68-3
Minumum % Wt:50.
Maxumum % Wt:70.
Name:TERTIARY DIAMINE (MFR CAS #65181-78-4)
Minumum % Wt:35.
Maxumum % Wt:45.
Name:SELENIUM
CAS:7782-49-2
RTECS #:VS7700000
< Wt:1.
Other REC Limits:XEL2: 50G/M3
OSHA PEL:0.2 MG/M3
ACGIH TLV:0.2 MG/M3
ACGIH STEL:0.2 PPM
EPA Rpt Qty:1 LB
DOT Rpt Qty:1 LB
Name:VINYL CHLORIDE/VINYL ACETATE/MALEIC ACID TERPOLYMER
CAS:9005-09-8
< Wt:1.
Name:ORGANOZIRCONIUM COMPOUND (MFR CAS #85626-36-4)
< Wt:1.
===================== Hazards Identification =====================
LD50 LC50 Mixture:> 5 G/KG (RATS). BASED ON CONSTITUENTS.
Routes of Entry: Inhalation:NO Skin:YES Ingestion:NO
Reports of Carcinogenicity:NTP:YES IARC:YES OSHA:YES
Health Hazards Acute and Chronic:SYMPTOMS OF OVEREXPOSURE: NONE.
PRIMARY ROUTE OF ENTRY: SKIN.
Explanation of Carcinogenicity:VINYL CHLORIDE: IARC GROUP 1, VOL. 19,
SUPPL. 7; 1987. OSHA REGULATED 29CFR. 1910.1017. LISTED ON NTP
NINTH REPORT ON CARCINOGENS, KNOWN TO BE HUMAN CARCINOGENS LIST.
CHEMINFO: ISSUE : 2000-1 (FEBR UARY, 2000): VINYL CHLORIDE EXPOSURE
MAY FORM LIVER, LUNG, LYMPH AND BLOOD FORMING SYSTEM, AND BRAIN AND
CENTRAL NERVOUS SYSTEM CANCER.
Medical Cond Aggravated by Exposure:NONE WHEN USED AS DESCRIBED BY
PRODUCT LITERATURE.
======================= First Aid Measures =======================
First Aid:SKIN: WASH WITH SOAP AND WATER. EYES: IMMEDIATELY FLUSH EYES
WITH POTABLE WATER FOR A MINIMUM OF 15 MIN. CONTACT PHYSICIAN .
INHALATION: REMOVE TO FRESH AIR. SUPPORT BREATHING. CONTACT
PHYSICIAN . INGESTION: CONTACT PHYSICIAN IMMEDIATELY . ADDITIONAL
INFORMATION: NONE.
===================== Fire Fighting Measures =====================
Flash Point:N.A.
Lower Limits:N.A.
Upper Limits:N.A.
Extinguishing Media:WATER, CARBON DIOXIDE, FOAM.
Fire Fighting Procedures:USE NIOSH-APPROVED SCBA AND FULL PROTECTIVE
EQUIPMENT . WHEN IN A MACHINE, TREAT AS AN ELECTRICAL FIRE.
Unusual Fire/Explosion Hazard:EXPOSURE TO HIGH TEMPERATURES CAN RESULT
IN MELTING AND PYROLYSIS. FUMES MAY CAUSE RESPIRATORY SYMPTOMS.
DELAYED EFFECTS MAY OCCUR UP TO 72 HOURS.
================== Accidental Release Measures ==================
Spill Release Procedures:NONE.
====================== Handling and Storage ======================
Handling and Storage Precautions:UNDER NO CIRCUMSTANCES SHOULD PUMICING
COMPOUNDS OR MECHANICAL ABRASION BE USED ON THIS PHOTORECEPTOR.
Other Precautions:AVOID EXPOSURE TO HIGH TEMPERATURES.
============= Exposure Controls/Personal Protection =============
Respiratory Protection:A NIOSH-APPROVED RESPIRATOR APPROPRIATE FOR THE
EXPOSURE OF CONCERN . NONE REQUIRED WHEN USED AS INTENDED IN XEROX
EQUIPMENT (MFR).
Protective Gloves:IMPERVIOUS GLOVES . NONE REQ'D WHEN USED AS INTENDED
IN XEROX EQUIP(MFR).
Eye Protection:ANSI-APPROVED SAFETY GLASSES . NONE REQUIRED WHEN USED
AS (SUP DAT)
Other Protective Equipment:EYEWASH MEETING ANSI DESIGN CRITERIA . NONE
REQUIRED WHEN USED AS INTENDED IN XEROX EQUIPMENT (MFR).
Supplemental Safety and Health
EYE PROTECTION: INTENDED IN XEROX EQUIPMENT (MFR).
================== Physical/Chemical Properties ==================
Boiling Pt:B.P. Text:N.A.
Melt/Freeze Pt:M.P/F.P Text:N.A.
Vapor Pres:N.A.
Vapor Density:N.A.
Spec Gravity:N.A.
pH:N.A.
Evaporation Rate & Reference:N.A.
Solubility in Water:INSOLUBLE
Appearance and Odor:SOLID/ODORLESS.
Percent Volatiles by Volume:N.A.
================= Stability and Reactivity Data =================
Stability Indicator/Materials to Avoid:YES
ORGANIC SOLVENTS; STRONG ACIDS/BASES.
Hazardous Decomposition Products:NONE.
=================== Toxicological Information ===================
Toxicological Information:THIS MATERIAL HAS BEEN EVALUATED BY XEROX
CORPORATION. ORAL LD50: >5 G/KG (RATS) PRACTICALLY NON-TOXIC (1).
DERMAL LD50: >2 G/KG (RABBITS) PRACTICALLY NON-TOXIC (1).
INHALATION LC50: N.A. EYE IRRITAT ION: NOT AN IRRITANT (1). SKIN
SENSITIZATION: NOT A SENSITIZER (1). SKIN IRRITATION: NOT AN
IRRITANT(1). HUMAN PATCH: NON-IRRITATING, NON-SENSITIZING (1).
MUTAGENICITY: NON-MUTAGENIC IN AMES ASSAY(1). CARCINOGENS: NONE
PRESENT. AQUATIC LC50: NOT DETERMINED. TLV: 0.2 MG/M3 (SELENIUM).
PEL: 0.2 MG/M3 (SELENIUM). STEL: NONE ESTABLISHED. CEILING: NONE
ESTABLISHED. XEL (2): 50MG/M3 (SELENIUM). (ECOLOG ICAL)
===================== Ecological Information =====================
Ecological:(TOXICOLOGICAL CONT) ADDITIONAL INFORMATION: NONE. (1) =
BASED ON TOXICITY DATA OF CONSTITUENTS. (2) = XEL - XEROX EXPOSURE
LIMIT.
==================== Disposal Considerations ====================
Waste Disposal Methods:DISPOSE OF IN ACCORDANCE WITH FEDERAL, STATE &
LOCAL REGULATIONS.
=================== MSDS Transport Information ===================
Transport Information:TRANSPORTATION EMERGENCY NO. (716) 422-1230.
D.O.T. PROPER SHIPPING NAME: NOT REGULATED. HAZARD CLASSIFICATION:
N.A. ID NUMBER: N.A.
======================= Other Information =======================
Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.
*** END OF RECORD *** |
|