===================== Product Identification =====================
MSDS NAME:STOP SLIP HDV, 20011, 20012, NON-SLIP SAFETY COATING
Status Code:A
MSDS Number: CKSXD
=== Responsible Party ===
Company:GARON PROD INC
Box:1924
City:WALL
State:NJ
ZIP:07719-1924
Country:US
Info Phone Num:800-631-5380
Emergency Phone Num:(800) 424-9300
Resp. Party Other MSDS Num.:M 193
Chemtrec Ind/Phone:(800)424-9300
CAGE:JO535
=== Contractor Identification ===
Company:GARON PROD INC
Box:1924
City:WALL
State:NJ
ZIP:07719-1924
Country:US
Phone:800-631-5380
CAGE:JO535
============= Composition/Information on Ingredients =============
Name:EPOXY RESIN
CAS:25068-38-6
RTECS #:CE6880000
Minumum % Wt:20.
Maxumum % Wt:40.
OSHA PEL:N.E.
ACGIH TLV:N.E.
Name:ALUMINO-SILICATE MINERAL
CAS:37244-96-5
Minumum % Wt:20.
Maxumum % Wt:30.
OSHA PEL:10 MG/M3
ACGIH TLV:3.5 MG/M3
Name:SILICON DIOXIDE (CRYSTALLINE SILICA - QUARTZ).
(NON-RESPIRABLE SIZE)
CAS:14808-60-7
RTECS #:VV7330000
Minumum % Wt:20.
Maxumum % Wt:30.
OSHA PEL:0.1 MG/M3
ACGIH TLV:0.1 MG/M3
Name:ALUMINUM OXIDE
CAS:1344-28-1
RTECS #:BD1200000
Minumum % Wt:20.
Maxumum % Wt:30.
OSHA PEL:15 MG/M3
ACGIH TLV:10 MG/M3
Name:TITANIUM DIOXIDE
CAS:13463-67-7
RTECS #:XR2275000
< Wt:5.
OSHA PEL:10 MG/M3
ACGIH TLV:10 MG/M3
===================== Hazards Identification =====================
Routes of Entry: Inhalation:YES Skin:YES Ingestion:YES
Reports of Carcinogenicity:NTP:YES IARC:YES OSHA:NO
Health Hazards Acute and Chronic:INHALATION: MAY CAUSE HEADACHES,
NAUSEA, DIZZINESS & RESPIRATORY IRRITATION IF INHALED. MAY CAUSE
ALLERGIC RESPIRATORY REACTION. SKIN: CONTAINS MATERIAL THAT MAY BE
MODERATELY TOXIC BY ABSORPTION. MAY CAUSE CHEMICAL BURNS AND
ALLERGIC SKIN REACTION WHICH CAN BE SEVERE IN CERTAIN INDIVIDUALS.
EYES: SEVERE IRRITANT. AGGREGATE MAY CAUSE INJURY. INGESTION: NO
SPECIFIC INFORMATION AVAILABLE. CONTAINS M ATERIALS THAT MAY BE
SLIGHTLY TOXIC.
Explanation of Carcinogenicity:SILICON DIOXIDE (CRYSTALLINE SILICA -
QUARTZ): IARC GROUP 1 CARCINOGEN, IARC MONOGRAPHS VOL 68, P 41,
1997; KNOWN HUMAN CARCINOGEN, NTP 9TH ANNUAL REPORT ON CARCINOGENS,
1998.
Effects of Overexposure:OVEREXPOSURE EFFECTS: IRRITATION, SENSITIZATION
& DERMATITIS.
Medical Cond Aggravated by Exposure:ALLERGY, ECZEMA AND OTHER SKIN
CONDITIONS.
======================= First Aid Measures =======================
Eyes: FLUSH WITH LARGE QUANTITIES OF WATER FOR AT LEAST 15
MINUTES. GET MEDICAL ATTENTION. SKIN: WASH CONTACT AREA WITH SOAP &
WATER FOR 15 MINUTES. REMOVE AND WASH CONTAMINATED CLOTHING BEFORE
REUSE. INHALATION: REMOVE TO FRESH AIR. GIVE OXYGEN IF BREATHING
IS DIFFICULT. GET MEDICAL ATTENTION. INGESTION: DO NOT INDUCE
VOMITING (CONTAINS SOLVENT). GET MEDICAL ATTENTION.
===================== Fire Fighting Measures =====================
Flash Point:>204.4C, 400.F
>400F/205C
Lower Limits:N.A.
Upper Limits:N.A.
Extinguishing Media:USE CARBON DIOXIDE OR DRY CHEMICAL FOR SMALL FIRES;
AQUEOUS FOAM OR WATER FOR LARGE FIRES.
Fire Fighting Procedures:REMOVE ALL IGNITION SOURCES. WEAR (NIOSH
APPROVED - ) SELF-CONTAINED BREATHING APPARATUS & COMPLETE PERSONAL
PROTECTIVE EQUIPMENT WHERE POTENTIAL FOR EXPOSURE TO VAPORS OR
PRODUCTS OF COMBUSTION E XISTS.
Unusual Fire/Explosion Hazard:CLOSED CONTAINERS MAY RUPTURE (DUE TO
BUILD UP OF PRESSURE) WHEN EXPOSED TO EXTREME HEAT. DECOMPOSITION &
COMBUSTION PRODUCTS MAY BE TOXIC.
================== Accidental Release Measures ==================
Spill Release Procedures:ELIMINATE ALL IGNITION SOURCES. DIKE SPILL.
ABSORB WITH INERT MATERIALS & COLLECT FOR DISPOSAL. FLUSH
CONTAMINATED AREA WITH WATER; PREVENT WASHINGS FROM ENTERING
WATERWAYS.
====================== Handling and Storage ======================
Handling and Storage Precautions:AVOID ALL PERSONAL CONTACT. DO NOT
EXCEED 110F/43C IN STORAGE AREA. GROUND & BOND METAL CONTAINERS FOR
LIQUID TRANSFER TO AVOID STATIC SPARKS.
Other Precautions:KEEP OUT OF REACH OF CHILDREN.
============= Exposure Controls/Personal Protection =============
Respiratory Protection:NIOSH APPROVED RESPIRATOR WITH ORGANIC VAPOR
CARTRIDGE IF REQUIRED.
Ventilation:EXPLOSION-PROOF MECHANICAL VENT & LOCAL EXHAUST
RECOMMENDED. MECHANICAL EXHAUST NOT RECOMMENDED AS THE SOLE MEANS
OF CONTROLLING EMPLOYEE EXPOSURE.
Protective Gloves:IMPERVIOUS GLOVES.
Eye Protection:ANSI APPROVED CHEMICAL SAFETY GOGGLES & FULL FACESHIELD
.
Other Protective Equipment:IN OPERATIONS WHERE CONTACT MAY OCCUR,
COVERALLS, APRON AND IMPERVIOUS FOOT COVERING ARE RECOMMENDED.
Work Hygienic Practices:A SAFETY SHOWER AND EYE WASH FACILITY SHOULD BE
AVIALABLE TO EMPLOYEES. IMMEDIATELY REMOVE AND THOROUGHLY LAUNDER
CONTAMINATED CLOTHING BEFORE REUSE.
Supplemental Safety and Health
================== Physical/Chemical Properties ==================
Boiling Pt:>148.9C, 300.F
B.P. Text:>300F/149C
Vapor Pres:<1MMGH@68F/20C
Vapor Density:> AIR
Spec Gravity:2.14
Evaporation Rate & Reference:SLOWER THAN BUTYL ACETATE
Solubility in Water:PRACTICALLY INSOLUBLE
Appearance and Odor:PIGMENTED VISCOUS LIQUID, MILD ODOR.
================= Stability and Reactivity Data =================
Stability Indicator/Materials to Avoid:YES
STRONG OXIDIZING AGENTS.
Stability Condition to Avoid:EXCESSIVE HEAT.
Hazardous Decomposition Products:CARBON MONOXIDE, CARBON DIOXIDE AND
ALDEGUDES.
=================== Toxicological Information ===================
Toxicological Information:LD50/LC50 (EPOXY RESIN, ALUMINO-SILICATE
MINERAL, SILICON DIOXIDE (NON-RESPIRABLE SIZE), ALUMINUM OXIDE,
TITANIUM DIOXIDE): N/A. CARCINOGENIC DATA: THIS PRODUCT MAY
CONTAIN INGREDIENTS CONSIDERED POT ENTIAL CARCINOGENS BY ACGIH,
FEDERAL OSHA, NTP, IARC OR CAL/OSHA. (SILICON DIOXIDE IS LISTED
WITH IARC AS A CLASS 2A: "PROBABLY CARCINOGENIC TO HUMANS"). SINCE
ALL SILICON DIOXIDE IS OF NON-RESPIRABLE SIZE AND ENCAPSULATED IN
THE COATING NO OVEREXPOSURE TO AIRBORNE DUSTS IS TO BE EXPECTED.
HOWEVER, DURING REMOVAL BY MECHANICAL ABRASION, APPROPRIATE SAFETY
PRACTICES SHOULD BE FOLLOWED TO PREVENT IN HALATION OF AIRBORNE
DUSTS.
==================== Disposal Considerations ====================
Waste Disposal Methods:THIS PRODUCT, IF DISPOSED AS SHIPPED, MEETS EPA
CRITERIA OF HAZARDOUS WASTE AS SPECIFIED IN 40 CFR 261 ON THE
BASIS OF ITS IGNITABILITY. DISPOSE OF IN A LICENSED HAZARDOUS
WASTE FACILITY IN ACCORDAN CE WITH APPLICABLE LAWS.
======================= Other Information =======================
Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.
*** END OF RECORD *** |
|