 NON-FLAMMABLE GAS MIXTURE
CAS  
:
 132259-10-0
1333-74-0
NAME  
:
 air (79% nitrogen, 21% oxygen)
hydrogen
=====================  Product Identification  =====================

MSDS NAME:NON-FLAMMABLE GAS MIXTURE
NIIN:01-456-6319
Status Code:A
MSDS Number: CLBFX
=== Responsible Party ===
Company:AIR LIQUIDE AMERICA CORP
Address:821 CHESAPEAKE DRIVE
City:CAMBRIDGE
State:MD
ZIP:21613
Country:US
Info Phone Num:410-228-6400;713-868-0440
Emergency Phone Num:713-868-0440
Resp. Party Other MSDS Num.:MSDS - 50009
Preparer's Name:CHEMICAL SAFETY ASSOCIATE
Chemtrec Ind/Phone:(800)424-9300
CAGE:04AA7
=== Contractor Identification ===
Company:AIR LIQUIDE AMERICA CORP
Address:821 CHESAPEAKE DRIVE
Box:City:CAMBRIDGE
State:MD
ZIP:21613
Country:US
Phone:410-228-6400;713-868-0440
CAGE:04AA7
Company:BACHARACH INC
Address:625 ALPHA DRIVE
Box:City:PITTSBURGH
State:PA
ZIP:15238
Country:US
Phone:412-963-2130
Contract Num:SP0450-01-M-D845
CAGE:05083

=============  Composition/Information on Ingredients  =============

Name:AIR (79% NITROGEN, 21% OXYGEN)
CAS:132259-10-0
= Wt:99.89
Code:F
= Vol:98.4
Code:F

Name:HYDROGEN
CAS:1333-74-0
RTECS #:MW8900000
= Wt:.11
Code:F
= Vol:1.6
Code:F

=====================  Hazards Identification  =====================

Routes of Entry: Inhalation:YES  Skin:NO  Ingestion:NO
Reports of Carcinogenicity:NTP:NO    IARC:NO	OSHA:NO
Health Hazards Acute and Chronic:ACUTE: DUE TO THE SMALL SIZE OF THE
    INDIVIDUAL CYLINDER OF THIS PRODUCT, NO UNUSUAL HEALTH EFFECTS FROM
    EXPOSURE TO THE PRODUCT ARE ANTICIPATED UNDER ROUTINE CIRCUMSTANCES
    OF USE. THE MOST SIGNIFICANT  HAZARD ASSOCIATED WITH THIS GAS
    MIXTURE WHEN IT CONTAINS LESS THAN 19.5% OXYGEN IS	THE POTENTIAL
    FOR EXPOSURE TO OXYGEN-DEFICIENT ATMOSPHERES. CHRONIC: THERE ARE
    CURRENTLY NO KNOWN ADVERSE HEALTH EF FECTS ASSOCIATED WITH CHRONIC
    EXPOSURE TO THIS GAS. TARGET ORGANS: RESPIRATORY SYSTEM.
Explanation of Carcinogenicity:THE COMPONENTS OF THIS GAS MIXTURE ARE
    NOT FOUND ON THE FOLLOWING LISTS: FEDERAL OSHA Z LIST, NTP,
    CAL/OSHA, AND IARC., THEREFORE, THEY ARE NOT CONSIDERED TO BE, NOR
    SUSPECTED TO BE, CANCER-CAUSING AG ENTS BY THESE AGENCIES.
Effects of Overexposure:NONE PROVIDED FOR THIS GAS MIXTURE  (1.6 VOL.%
    HYDROGEN  IN AIR).
Medical Cond Aggravated by Exposure:PRE-EXISTING RESPIRATORY CONDITIONS
    MAY BE AGGRAVATED BY OVER-EXPOSURE TO THIS PRODUCT.

=======================  First Aid Measures  =======================

First Aid:NO UNUSUAL HEALTH EFFECTS ARE ANTICIPATED AFTER EXPOSURE TO
    PRODUCT DUE TO SMALL CYLINDER SIZE AND PRODUCTS LOW CONCENTRATION
    OF HYDROGEN (1.6 VOL. % IN AIR).

=====================  Fire Fighting Measures  =====================

Flash Point:NON-FLAMMABLE
Lower Limits:NOT APPLICAB
Upper Limits:NOT APPLICAB
Extinguishing Media:NON-FLAMMABLE GAS MIXTURE. USE EXTINGUISHING MEDIA
    APPROPRIATE FOR SURROUNDING FIRE.
Fire Fighting Procedures:STRUCTURAL FIREFIGHTERS MUST WEAR SELF
    CONTAINED BREATHING APPARATUS AND FULL PROTECTIVE EQUIPMENT.
Unusual Fire/Explosion Hazard:THIS GAS MIXTURE IS NOT FLAMMABLE;
    HOWEVER, CONTAINERS, WHEN INVOLVED IN FIRE, MAY RUPTURE OR BURST IN
    THE HEAT OF THE FIRE. PRODUCT IS NOT EXPLOSION SENSITIVE TO
    MECHANICAL IMPACT NOR TO STATIC DISCH ARGE.

==================  Accidental Release Measures  ==================

Spill Release Procedures:IN  EVENT OF RELEASE IN WHICH ATMOSPHERE IS
    UNKNOWN, AND IN WHICH OTHER CHEMICALS ARE POTENTIALLY INVOLVED,
    EVACUATE IMMEDIATE AREA. SUCH RELEASES SHOULD BE RESPONDED TO BY
    TRAINED PERSONNEL USING PRE -PLANNED PROCEDURES. PROPER PROTECTIVE
    EQUIPMENT SHOULD BE USED. IN CASE OF LEAK , CLEAR AREA, PROTECT
    PEOPLE, AND RESPOND WITH TRAINED PERSONNEL. IF LEAKING FROM
    CYLINDER, CONTACT YOUR SUPPLIER.

======================	Handling and Storage  ======================

Handling and Storage Precautions:FIRMLY SECURE CYLINDERS TO PREVENT
    FALLING OR BEING KNOCKED OVER. PROTECT CYLINDERS FROM ENVIRONMENT.
    STORE AT ROOM TEMPERATURE 70F) INDRY, WELL-VENTILATED AREA, AWAY
    FROM SOURCES OF HEAT, IGNITION, A ND DIRECT SUNLIGHT. PROTECT
    CYLINDERS AGAINST PHYSICAL DAMAGE. SEGREGATE FULL AND EMPTY
    CYLINDERS.
Other Precautions:USE FIRST IN, FIRST OUT INVENTORY. THESE CYLINDERS
    ARE NOT REFILLABLE. WARNING! DO NOT REFILL DOT 39 CYLINDERS, MAY
    CAUSEL INJURY OR PROPERTY DAMAGE. USE EQUIPMENT DESIGNED FOR THESE 
    CYLINDERS. ENSUR E LINES AND EQUIPMENT ARE RATED FOR PROPER SERVICE
    PRESSURE. ALWAYS USE PRODUCT IN AREAS WITH	ADEQU ATE VENTILATION.

=============  Exposure Controls/Personal Protection  =============

Respiratory Protection:NO SPECIAL RESPIRATORY PROTECTION REQUIRED UNDER
    NORMAL USE FOR AIR BASED GAS MIXTURE WITH 1.6% (VOLUME) OF HYDROGEN
    IN AIR.
Ventilation:NO SPECIAL VENTILATION SYSTEMS OR ENGINEERING CONTROLS ARE
    NEEDED UNDER NORMAL USE.
Protective Gloves:NO SPECIAL PROTECTION IS NEEDED UNDER NORMAL
    CIRCUMSTANCES OF USE.
Eye Protection:SAFETY GLASSES.
Other Protective Equipment:NONE REQUIRED FOR  AIR BASED GAS MIXTURE
    WITH 1.6% (VOLUME) OF HYDOGEN IN AIR.
Work Hygienic Practices:NONE PROVIDED BY MFR.
Supplemental Safety and Health
BACHARACH INC (CAGE 05083) PART NUMBER: 51-2576. MANUFACTURER'S MSDS
    COVERS PRODUCTS IN NITROGEN. THIS NSN PRODUCT IS 1.6% (VOLUME)
    HYDROGEN IN AIR.

==================  Physical/Chemical Properties  ==================

HCC:G3
Boiling Pt:=-195.6C, -320.4F
B.P. Text:FOR N2 BASED MIXTURE.
Melt/Freeze Pt:=-209.7C, -345.8F
M.P/F.P Text:@ 10 PSIG(FOR N2 BASED)
Spec Gravity:1 FOR AIR BASED MIX.
Solubility in Water:0.023 @ 32F,1 ATM (N2)
Appearance and Odor:COLORLESS, ODORLESS GAS.

=================  Stability and Reactivity Data  =================

Stability Indicator/Materials to Avoid:YES
HYDROGEN IS INCOMPATABLE WITH STRONG OXIDIZERS (I.E. CHLORINE,
    BROMEINE, PENTAFLUORIDE, OXYGEN DISULFIDE, AND NITROGEN
    TRIFLUORIDE).
Stability Condition to Avoid:NORMALLY STABLE IN GASEOUS STATE. AVOID
    CONTACT WITH INCOMPATIBLE MATERIALS. CYLINDERS EXPOSED TO HIGH
    TEMPERATURES OR DIRECT FLAME CAN RUPTURE OR BURST.
Hazardous Decomposition Products:HYDROGEN DOES NOT DECOMPOSE, PER SE,
    BUT CAN REACT WITH OTHER COMPOUNDS IN THE HEAT OF A FIRE.
Conditions to Avoid Polymerization:WILL NOT OCCUR.

===================  Toxicological Information	===================

Toxicological Information:THERE ARE NO TOXICOLOGY DATA FOR HYDROGEN.
    HYDROGEN IS A SIMPLE ASPHYXIANT (SA), WHICH ACTS TO DISPLACE OXYGEN
    IN THE ENVIRONMENT. COMPONENTS OF THIS GAS ARE NOT FOUND ON THE
    FEDERAL OSHA Z LIST, NTP,  CAL/OSHA, AND IARC; THEREFORE, THEY ARE
    NOT CONSIDERED TO BE, NOR SUSPECTED TO BE, CANCER-CAUSING AGENTS.
    NO MUTAGENICITY, NO EMBRYOTOXIC, NO TERATOGENICITY, AND NO
    REPRODUCTIVE TOXICITY EFFECTS HAVE	BEEN DESCRIBED FOR THIS GAS
    MIXTURE. ACUTE OR CHRONIC RESPIRATORY CONDITIONS MAY BE AGGRAVATED
    BY OVER-EXPOSURE TO COMPONENTS OF PRODUCT.

=====================  Ecological Information  =====================

Ecological:ENVIRONMENTAL STABILITY: THE COMPONENTS OF THIS GAS MIXTURE
    OCCUR NATURALLY IN THE ATMOSPHERE. THE GAS WILL BE DISSIPATED
    RAPIDLY IN WELL-VENTILATED AREAS. EFFECTS OF MATERIAL ON PLANTS OR
    ANIMALS: NO  EVIDENCE IS CURRENTLY AVAILABLE ON THIS PRODUCT'S
    EFFECTS ON PLANT AND ANIMAL LIFE. EFFECTS OF CHEMICAL ON AQUATIC
    LIFE: NO EVIDENCE IS CURRENTLY AVAILABLE ON THIS PRODUCT'S EFFECTS
    ON AQUATIC LIFE.  THIS GAS MIXTURE DOES NOT CONTAIN ANY CLASS I OR
    CLASS I I OZONE DEPLETING CHEMICALS (40 CFR PART 82).

====================  Disposal Considerations  ====================

Waste Disposal Methods:WASTE DISPOSAL MUST BE IN ACCORDANCE WITH
    APPROPRIATE FEDERAL, STATE, AND LOCAL REGULATIONS. CYLINDERS WITH
    UNDESIRED RESIDUAL PRODUCT MAY BE SAFELY VENTED OUTDOORS WITH
    PROPER REGULATOR. CYLINDERS RE LEAVED OF PRESSURE (EMPTY)  ARE NOT
    CONSIDERED HAZARDOUS MATERIAL OR WASTE AND CAN BE DISPOSED IN A 
    LANDFILL IF LOCAL LAWS PERMIT.

===================  MSDS Transport Information  ===================

Transport Information:THIS MATERIAL IS HAZARDOUS AS DEFINED BY 49 CFR
    172.101 BY THE U.S. DEPARTMENT OF TRANSPORTATION: PROPER SHIPPING
    NAME: COMPRESSED GASES, N.O.S., (HYDROGEN, AIR);  HAZARD CLASS 2.2,
    (NON-FLAMMABLE GAS ); UN 1956; PKG, NOT APPLICABLE; DOT LABEL
    REQUIRED: NON-FLAMMABLE GAS; NORTH AMERICAN EMERGENCY RESPONSE
    GUIDEBOOK NUMBER (1996): 126. MARINE POLLUTANT: THE COMPONENTS OF
    THIS GAS MIXTURE ARE NOT CLA SSIFIED AS MARINE POLLUTANTS (AS
    DEFINED BY 49 CFR 172.101, APPENDIX B). CANADA TRANSPORTATION:
    PRODUCT IS CONSIDERED AS DANGEROUS GOODS. USE SAME DOT INFORMATION
    FOR PREPARATION OF CANADIAN SHIPMENTS .

=====================  Regulatory Information  =====================

SARA Title III Information:THIS PRODUCT IS NOT SUBJECT TO THE REPORTING
    REQUIREMENTS OF SECTIONS 302, 304, AND 313. SARA THRESHOLD PLANNING
    QUANTITY: NOT APPLICABLE. U.S. FEDERAL REGULATION: HYDROGEN IS
    LISTED AS REGULATED SUBS TANCE, PER 40 CFR PART 68 OF THE RISK
    MANAGEMENT FOR CHEMICAL RELEASES IN TABLE 3 AS REGULATED SUBSTANCE
    (FLAMMABLE SUBSTANCES), IN QUANTITIES OF 10,000 LBS (4,553 KG) OR
    GREATER, SO THIS MIXTURE WILL  NOT BE AFFECTED BY THE REGULATION..
Federal Regulatory Information:TSCA INVENTORY STATUS: THE COMPONENTS OF
    THIS GAS MIXTURE ARE LISTED ON THE TSCA INVENTORY. CERCLA
    REPORTABLE QUANTITY (RQ): NOT APPLICIABLE. NO COMPONENT OF THIS GAS
    MIXTURE IS SUBJECT TO THE REQUIRE MENTS OF CFR 29 1910.1000. THE
    REGULATIONS OF THE PROCESS SAFETY MANAGEMENT OF HIGHLY HAZARDOUS
    CHEMICALS (29 CFR 1910. 119) ARE NOT APPLICABLE TO THIS GAS
    MIXTURE. HYDROGEN IS SUBJECT TO THE REPORTIN G REQUIREMENTS OF
    SECTION 112(R) OF THE CLEAN AIR ACT. THE THRESHOLD QUANTITY  IS
    10,000 POUNDS SOTH IS MIXTURE WILL NOT BE AFFECTED BY THIS
    REGULATION..
State Regulatory Information:THE HYDROGEN COMPONENT OF THIS GAS MIXTURE
    IS COVERED UNDER FOLLOWING SPECIFIC STATE REGULATIONS: ALASKA:
    DESIGNATED TOXIC AND HAZARDOUS SUBSTANCE; CA: PERMISSIBLE EXPOSURE
    LIMITS FOR CHEMICAL CONTAMI NANTS; FL: SUBSTANCE LIST; IL:TOXIC
    SUBSTANCE LIST;MA: SUBSTANCE LIST; MN: LIST OF HAZARDOUS
    SUBSTANCES; MO: EMPLOYER INFORMATION/TOXIC SUBSTANCE LIST; NJ:
    RIGHT-TO-KNOW HAZARDOUS SUBSTANCE LIST; PA:  HAZARDOUS SUBSTANCE
    LIST; RI: HAZARDOUS SUBSTANCE LIST; CALIFORNIA PROPOSITION 65: NO
    COMPONENT OF T HIS PRODUCT IS ON THE CALIFORNIA PROPOSITION 65
    LIST.

=======================  Other Information  =======================

 Disclaimer (provided with this information by the compiling agencies):
 This information is formulated for use by elements of the Department
 of Defense.  The United States of America in no manner whatsoever,
 expressly or implied, warrants this information to be accurate and
 disclaims all liability for its use.  Any person utilizing this
 document should seek competent professional advice to verify and
 assume responsibility for the suitability of this information to their
 particular situation.

*** END OF RECORD ***
Search More   
ALL PAGES On Chemical Property IN THIS GROUP
NAMECAS
BLACK QUICK DRY MIMEO INK 8012-95-1
1333-86-4
INK, BLACK DRAWING OR LETTERBOX F#6474 67-63-0
1333-86-4
122-99-6
104-68-7
CRYSTALLINE SILICA (QUARTZ) 14808-60-7
UNIVERSAL BLACK TYPE M STENCIL INK 64-17-5
111-76-2
142-82-5
71-23-8
141-78-6
108-88-3
KAULO 10TH AF INSULATION 13983-17-0
FIBERGLASS INSULATION, KRAFT FACED INSULATION, FOIL FACED IN 65997-17-3
F-100 INK 64-17-5
947-19-3
O-D-825C TYPE II 64-17-5
67-56-1
111-76-2
3068 RAPIDOOZE PEN CLEANER 1310-58-3
102-71-6
7732-18-5
291 KOH=I-LAR LIQUID ERASER 71-36-3
1336-21-6
7732-18-5
SODIUM CARBONATE, MONOHYDRATE 6132-02-1
KIMTEX WIPERS #33560 AND #33570 9003-07-0
MERCURY 7439-97-6
SCOTCH BRAND ALUMINUM FOIL TAPE NO 425 7429-90-5
79-10-7
LITHOGRAPHIC INK 1333-86-4
25085-50-1
64741-59-9
8042-47-5
68956-68-3
61788-66-7
67746-08-1
INK-LINGS 9016-45-9
7705-14-8
9002-93-1
7732-18-5
ABM SPRAY INK 8000-41-7
123-86-4
108-88-3
1330-20-7
67-64-1
74-98-6
75-28-5
106-97-8
ABM SPRAY INK 8000-41-7
123-86-4
108-88-3
1330-20-7
67-64-1
74-98-6
75-28-5
106-97-8
ABM SPRAY INK 8000-41-7
123-86-4
108-88-3
1330-20-7
67-64-1
74-98-6
75-28-5
106-97-8
METHYL ALCOHOL, PART A, (SEE SUPPLEMENTAL DATA) 67-56-1
7432802, TECTYL 802 A 64742-52-5
8020-84-6
AEROSHELL GREASE 14 (MIL-G-25537; MIL-G-25537C) 64742-46-7
64742-53-6
64742-56-9
3159-62-4
NAPHTHOL GREEN B, (SEE SUPPLEMENTARY DATA) 19381-50-1
HYDROCHLORIC ACID, 30-40% 7647-01-0
7732-18-5
2,2,4-TRIMETHYLPENTANE, (SEE SUPPLEMENTAL DATA) 540-84-1
METHANE IN AIR 74-82-8
132259-10-0
BATTERY ELECTRIC STORAGE, DRY CHARGED
PST-525 63148-62-9
112945-52-5
CESIUM FLUORIDE, PART C, (SEE SUPPLEMENTAL DATA) 13400-13-0
SI12-500, BROMOPHENOL BLUE SOLUTION 0.04% 62625-28-9
7732-18-5
ETHYL ACETATE 141-78-6
LUMOR 3X (AEROSOL), CODE 2385 124-38-9
NON-FLAMMABLE GAS MIXTURE 74-82-8
132259-10-0
MIL-C-846B
ROYCO 560 67762-53-2
67762-52-1
68259-36-9
68411-46-1
1330-78-5
TBN CALIBRATION OIL STANDARD 64742-65-0
NON-FLAMMABLE GAS MIXTURE 132259-10-0
1333-74-0
DOW CORNING (R) 3451 CHEMICAL RESISTANT BEARING GREASE
57055A, 570A INHIBITOR PART A 7664-38-2
AI 8493-3K AIR FORCE TYPE I I I, CLEANING COMPOUND
897 9668, YELLOW TONER Y1 39382-25-7
72869-85-3
ALCOHOL, DENATURED 64-17-5
67-56-1
DITHI VER METALS REAGENT POWDER PILLOWS, 12616 7681-57-4
GUM MASTIC SOLUTION, ALCOHOLIC HT101-3, COMPONENT OF HT101-2 61789-92-2
64-17-5
SINTEC, VERDUGO, 7537 1330-20-7
64742-88-7
01596 HAVOLINE OUTBOARD 2-CYCLE ENGINE OIL 64742-53-6
72623-83-7
SHEET FED OIL BASE INK 8002-05-9
8052-41-3
SHEET FOIL OIL BASE OFFSET INK 3-5110 8002-05-9
8052-41-3
SHEET FED OIL BASE OFFSET INK 8002-05-9
8052-41-3
TALCUM POWDER 14807-96-6

Free MSDS Search ( Providing 250,000+ Material Properties )
Chemcas.com| Ads link:todaystock.net