===================== Product Identification =====================
MSDS NAME:21950 HACH ONE REFERENCE ELECTRODE SOLUTION
NIIN:00F004025
MSDS Number: BBPHZ
=== Responsible Party ===
Company:HACH CO.
Address:100 DAYTON RD.
Box:907
City:AMES
State:IA
ZIP:50010-6402
Country:US
Info Phone Num:800-227-4224
Emergency Phone Num:303-623-5716(MEDICAL) 515-232-2533
CAGE:4T252
=== Contractor Identification ===
Company:HACH CO
Address:5600 LINDBERGH DR
Box:389
City:LOVELAND
State:CO
ZIP:80539
Country:US
Phone:970-669-3050/ 303-623-5716
CAGE:91224
Company:HACH COMPANY
Address:100 DAYTON RD.
Box:907
City:AMES
State:IA
ZIP:50010
Country:US
Phone:800-227-4224
CAGE:4T252
============= Composition/Information on Ingredients =============
Name:GLYCERIN
CAS:56-81-5
RTECS #:MA8050000
Fraction by Wt: <45%
OSHA PEL:15 MG/M3 TDUST
ACGIH TLV:10 MG/M3 (MIST) 9293
Name:POTASSIUM CHLORIDE
CAS:7447-40-7
RTECS #:TS8050000
Fraction by Wt: <20%
Name:OTHER COMPONENTS (TYPE NOT SPECIFIED)
Fraction by Wt: <0.1% EA
Other REC Limits:NOT REPORTED
Name:WATER
CAS:7732-18-5
RTECS #:ZC0110000
Fraction by Wt: TO 100%
Name:WATER
CAS:7732-18-5
RTECS #:ZC0110000
Fraction by Wt: <100%
===================== Hazards Identification =====================
Routes of Entry: Inhalation:YES Skin:YES Ingestion:YES
Reports of Carcinogenicity:NTP:NO IARC:NO OSHA:NO
Health Hazards Acute and Chronic:PRODUCT IS MILDLY IRRITATING TO BODY
TISSUES AND IS ONLY SLIGHTLY TOXIC.
Explanation of Carcinogenicity:NO INGREDIENT IS LISTED AS A CARCINOGEN
BY THE ABOVE AGENCIES.
Effects of Overexposure:EYE:IRRITATION. SKIN:IRRITATION WITH
PROLONGER/REPEATED CONTACT. INHALED:A VERY UNLIKELY EXPOSURE.
INGESTED:SLIGHTLY TOXIC. EXPECT G/I IRRITATION, NALUSEA.
Medical Cond Aggravated by Exposure:LIVER & KIDNEY DISFUNCTION NAY BE
ENHANCED.
======================= First Aid Measures =======================
First Aid:EYE:FLUSH W/WATER 15 MIN, HOLD LIDS OPEN. SKIN:WASH WITH
SOAP & WATER. INHALED:UNLIKELY EXPOSURE. REMOVE TO FRESH AIR IF
MIST IS INHALED. INGESTED:GIVE 2 GLASSES OF MILK OR WATER, AND GET
IMMEDIATE MEDICAL CARE.
===================== Fire Fighting Measures =====================
Flash Point:NON-FLAMMABLE
Extinguishing Media:USE CARBON DIOXIDE, FOAM, DRY CHEMICAL, OR WATER
FOG.
Fire Fighting Procedures:FIRE FIGHTERS SHOULD USE NIOSH APPROVED SCBA &
FULL PROTECTIVE EQUIPMENT WHEN FIGHTING CHEMICAL FIRE. USE WATER
SPRAY TO COOL NEARBY CONTAINERS EXPOSED TO FIRE.
Unusual Fire/Explosion Hazard:FIRE OR EXCESSIVE HEAT MAY CAUSE
PRODUCTION OF HAZARDOUS DECOMPOSITION PRODUCTS.
================== Accidental Release Measures ==================
Spill Release Procedures:MOP UP WITH CLOTH, PAPER, ETC.
Neutralizing Agent:NONE
====================== Handling and Storage ======================
Handling and Storage Precautions:STORE TIGHTLY CLOSED.
Other Precautions:NONE
============= Exposure Controls/Personal Protection =============
Respiratory Protection:NOT NORMALLY REQUIRED. USE NIOSH/MSHA APPROVED
RESPIRATOR IF PEL/TLV IS EXCEEDED.
Ventilation:NORMAL ROOM VENTILATION IS USUALLY SUFFICIENT.
Protective Gloves:NOT NORMALLY REQUIRED.
Eye Protection:SAFETY GLASSES OR SPLASH GOGGLES
Other Protective Equipment:EYE WASH STATION & SAFETY SHOWER. LAB HOOD
Work Hygienic Practices:USE GOOD CHEMICAL HYGIENE PRACTICES. AVOID ANY
UNNECESSARY CONTACT.
Supplemental Safety and Health
CHANGE NUMBER 8170.
================== Physical/Chemical Properties ==================
HCC:N1
Boiling Pt:B.P. Text:210F,99C
Spec Gravity:1.21
pH:6.16
Solubility in Water:MISCIBLE
Appearance and Odor:CLEAR, COLORLESS LIQUID, ODOR NOT REPORTED
Percent Volatiles by Volume:UNKNON
================= Stability and Reactivity Data =================
Stability Indicator/Materials to Avoid:YES
STRONG OXIDIZING AGENTS
Stability Condition to Avoid:HIGH TEMPERATURES, SPARKS, AND OPEN FLAMES
Hazardous Decomposition Products:NONE REPORTED. EXPECT CARBON MONOXIDE
AND CARBON DIOXIDE.
==================== Disposal Considerations ====================
Waste Disposal Methods:I/A/W FEDERAL, STATE, LOCAL REGULATIONS. MFR
SUGGESTS DILUTE AND FLUSH TO DRAIN.
Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.
*** END OF RECORD *** |
|