===================== Product Identification =====================
MSDS NAME:FP-95A(M) PENETRANT
NIIN:01-268-6705
MSDS Number: BGXDY
=== Responsible Party ===
Company:MET-L-CHEK COMPANY
Address:1639 EUCLID STREET
City:SANTA MONICA
State:CA
ZIP:90404-3770
Country:US
Info Phone Num:213-450-1111
Emergency Phone Num:213-450-1111
CAGE:98733
=== Contractor Identification ===
Company:MET-L-CHEK COMPANY
Address:1639 EUCLID ST
Box:00000
City:SANTA MONICA
State:CA
ZIP:90404
Country:US
Phone:310-450-1111/FAX 310452-4046
CAGE:98733
============= Composition/Information on Ingredients =============
Name:DISTILLATE (PETROLEUM),HYDROTREATED MIDDLE; ON MSDS MFR
SIMPLY NOTED AS "PETROLEUM HYDROCARBON" FOR ABOVE CAS NO.
CAS:64742-46-7
RTECS #:JN9379645
OSHA PEL:5MG/CUM
ACGIH TLV:5MG/CUM
===================== Hazards Identification =====================
Routes of Entry: Inhalation:YES Skin:YES Ingestion:YES
Reports of Carcinogenicity:NTP:NO IARC:NO OSHA:NO
Health Hazards Acute and Chronic:MAY CAUSE SLIGHT SKIN
IRRITATION;VAPORS OR OIL MIST MAY CAUSE MILD IRRITATION OF UPPER
RESPIRATORY TRACT.
Effects of Overexposure:EYES:PRESUMED NON-IRRITATING+SKIN: SLIGHT
IRRITATION ON LIQUID CONTACT;INHALATION:VAPORS OR OIL MIST MAY
CAUSE MILD IRRITATION OF UPPER RESPIRATORY TRACT;INGESTION:MAY
RESULT IN VOMITING.
Medical Cond Aggravated by Exposure:PRE-EXISTING SKIN AND RESPIRATORY
DISORDERS MAY BE AGGRAVATED BY EXPOSURE TO THIS PRODUCT.
======================= First Aid Measures =======================
Eyes:FLUSH WITH WATER.GET MEDICAL HELP IF IRRITATION OCCURS
OR PERSISTS; SKIN:FLUSH WITH WATER.WASH WITH WATER & SOAP.GET MED
ATTN FOR PERSISTING IRRITATION;INHALATION:REMOVE TO FRESH
AIR,PROVIDE OXYG EN IF BREATHING IS DIFFICULT GET MED ATTN IF
NEEDED; INGESTION: DO NOT INDUCE VOMITING.GET MEDICAL ATTENTION.
===================== Fire Fighting Measures =====================
Flash Point Method:COC
Flash Point:210F(98.9C)
Extinguishing Media:WATER FOG,DRY CHEMICAL,CARBON DIOXIDE OR FOAM; DO
NOT USE DIRECT STREAM OF WATER.
Fire Fighting Procedures:IN CONFINED AREA,DO NOT ENTER WITHOUT A FULL
BUNKER GEAR INCLUDING A POSITIVE PRESSURE NIOSH APPROVED
SELF-CONTAINED BREATHING APPARATUS.
Unusual Fire/Explosion Hazard:NOT KNOWN
================== Accidental Release Measures ==================
Spill Release Procedures:ELIM IGNITION SOURCES.WEAR APPROPRIATE
PROTECTIVE CLOTHING & RESPIRATOR.DIKE & TRANSFER LIQ TO SALVAGE
TANK.SOAK UP RESIDUE WITH ABSORBENT CLAY,SAND OR OTHR MATL.PLACE
RAGS & ABSORBED WASTE MATERL IN COVERED NON-LEAKING CONTAINERS.
====================== Handling and Storage ======================
Handling and Storage Precautions:KEEP AWAY FROM HEAT/IGNITION SOURCES.
STORE IN DRY,COOL,& VENTILATED LOCATION. DO NOT STORE NEAR
OXIDIZING MATERIAL. AVOID PHYSICAL DAMAGE TO CANS.
Other Precautions:MINIMIZE SKIN CONTACT.
============= Exposure Controls/Personal Protection =============
Respiratory Protection:IF EXPOSURE EXCEEDS TLV,USE NIOSH APPRVD
RESPIRATOR TO PREVENT OVEREXPOSURE.
Ventilation:PER MANUFACTUER,PROVIDE LOCAL EXHAUST, OR
MECHANICAL(GENERAL) VENTOLATION TO MAINTAIN TLV.
Protective Gloves:CHEMICAL RESISTANT
Eye Protection:GOGGLES
Other Protective Equipment:EYE WASH FOUNTAINS AND SAFETY SHOWERS.
Work Hygienic Practices:WASH WITH SOAP AND WATER BEFORE
EATING,DRINKING,SMOKING OR USING TIOLET FACILITIES.
Supplemental Safety and Health
PER QPL-25135-15,FP-95A(M)PENETRANT,AND E-58 EMULSFIER ARE QUALIFIED
ITEMS FOR AN NSN OF A KIT OR A SINGLE PRODUCT UNDR TYPE I,METHOD
D,LEVEL 3 OF MIL-I-25135D.THIS ENTRY DESCRIBES FP-95A(M) PENETRANT
UNDER THIS NSN WHICH IS SINGLE PRODUCTNSN OF TYPE I,METHOD D,LEVEL
3.E-58A/58D EMULSIFIER IS COVERED UNDER SEPRATE NSN
================== Physical/Chemical Properties ==================
HCC:N1
Boiling Pt:B.P. Text:>400F/>204C
Spec Gravity:0.86
Solubility in Water:NEGLIGIBLE
Appearance and Odor:YELLOW-GREEN LIQUID.SLIGHT HYDROCARBON ODOR.
================= Stability and Reactivity Data =================
Stability Indicator/Materials to Avoid:YES
OXIDIZING MATERIAL
Stability Condition to Avoid:HEAT & IGNITION SOURCES.
Hazardous Decomposition Products:CARBON MONOXIDE & OTHER UNIDENTIFIED
ORGANIC COMPOUNDS.
==================== Disposal Considerations ====================
Waste Disposal Methods:DISPOSE OF AS EPA HAZARDOUS WASTE
#D001,IGNITABLE WASTE.PLACE WASTE MATERIAL IN AN APPROPRIATE
DISPOSAL FACILITY,OR DISPOSE OF IN COMPLIANCE WITH FEDERAL,STATE &
LOCAL REGULATIONS.
Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.
*** END OF RECORD *** |
|