===================== Product Identification =====================
MSDS NAME:DELTA-LITE FIBREGLASS CASTING TAPE
NIIN:01-196-6204
MSDS Number: BHYDR
=== Responsible Party ===
Company:JOHNSON & JOHNSON HOSPITAL SERVICES INC
Address:501 GEORGE STREET
City:NEW BRUNSWICK
State:NJ
ZIP:08903
Country:US
Info Phone Num:800-526-2459
Emergency Phone Num:800-526-2459
CAGE:79717
=== Contractor Identification ===
Company:JOHNSON & JOHNSON HOSPITAL SERVICES INC.
Address:501 GEORGE STREET
Box:4000
City:NEW BRUNSWICK
State:NJ
ZIP:08903
Country:US
Phone:800-255-2500
CAGE:79717
============= Composition/Information on Ingredients =============
Name:POLYPROPYLENE POLYOL DIPHENYL METHANE DIISOCYANATE
PREPOLYMER
CAS:9048-57-1
Fraction by Wt: 31-34%
Other REC Limits:NONE SPECIFIED
Name:METHYLENE BISPHENYL ISOCYANATE (MDI) (SARA III)
CAS:101-68-8
RTECS #:NQ9350000
Fraction by Wt: 5-8%
Other REC Limits:NONE SPECIFIED
OSHA PEL:C, 0.02 PPM
ACGIH TLV:0.005 PPM; 9192
EPA Rpt Qty:1 LB
DOT Rpt Qty:1 LB
Name:ALUMINUM (SARA III)
CAS:7429-90-5
RTECS #:BD0330000
Fraction by Wt: 5%
Other REC Limits:NONE SPECIFIED
OSHA PEL:15MG/M3 DUST/5 FUME
ACGIH TLV:10MG/M3 DUST; 9192
Name:FIBERGLASS
Fraction by Wt: 54%
Other REC Limits:NONE SPECIFIED
OSHA PEL:15 MG/M3(TOTAL DUST)
ACGIH TLV:10 MG/M3 (DUST)
Name:POLYETHYLENE AS A COPOLYMER
Fraction by Wt: 2%
Other REC Limits:NONE SPECIFIED
===================== Hazards Identification =====================
LD50 LC50 Mixture:ORAL LD50 (RAT) IS UNKNOWN.
Routes of Entry: Inhalation:NO Skin:YES Ingestion:NO
Reports of Carcinogenicity:NTP:NO IARC:NO OSHA:NO
Health Hazards Acute and Chronic:EYES: CURING OF PREPOLYMER AND CAST
REMOV MAY CAUSE EYE AND SKIN IRRITATION. HEATING BEFORE CURING MAY
RELEASE ISOCYANAT VAPORS WHICH MAY CAUSE RESPIRATORY TRACT
IRRITATION. INGESTION MAY CAUSE IRRITA TION WITH POSSIBLE CORROSIVE
ACTION. EXCESSIVE EXPOSURE TO VAPORS MAY CAUSE PULMONARY EDEMA AND
MAY BE DELAYED.
Effects of Overexposure:REDNESS, SMARTING, TEARING & SWELLING OF THE
EYE. DRYNESS & CRACKING OF THE SKIN. VOMITING FROM INGESTION.
INGESTION OF THE CAST MATERIAL MAY CAUSE PHYSICAL BLOCKAGE OF THE
GI TRACT.
Medical Cond Aggravated by Exposure:PEOPLE WITH CHRONIC DISEASES OF THE
SKIN MAY BE AT INCREASED RISK WHEN EXPOSED TO THIS MATERIAL.
======================= First Aid Measures =======================
First Aid:INHALATION: MOVE PERSON TO FRESH AIR.RESTORE BREATHING. TREAT
SYMPTOMATICALLY. GET MEDICAL HELP. EYES: FLUSH IMMEDIATELY WITH
LARGE AMOUNTS OF WATER FOR AT LEAST 15 MINUTES. GET MEDICAL
TREATMENT. SKI N: WASH AFFECTED SKIN AREAS WITH SOAP AND WATER.
REMOVE CONTAMINATED CLOTHING. CONSULT A PHYSICIAN FOR ALLERGIC SKIN
REACTION.INGESTION: DO NOT INDUCE VOMITING: GET IMMEDIATE MEDICAL
ATTENTION.
===================== Fire Fighting Measures =====================
Flash Point Method:PMCC
Flash Point:>350F,>177C
Autoignition Temp:Autoignition Temp Text:NONE
Extinguishing Media:USE WATER FOG, CARBON DIOXIDE, FOAM, OR DRY
CHEMICAL.
Fire Fighting Procedures:FIRE FIGHTERS SHOULD USE NIOSH APPROVED SCB &
FULL PROTECTIVE EQUIPMENT WHEN FIGHTING CHEMICAL FIRE.
Unusual Fire/Explosion Hazard:FIRES CAN RELEASE NITROGEN OXIDES AND
ISOCYANATE VAPORS.
================== Accidental Release Measures ==================
Spill Release Procedures:EXPOSED PREPOLYMER WILL REACT WITH AMBIENT
MOISTURE AND POLYMERIZE (HARDEN). A DILUTE AMMONIA SOLUTION (10%)
WILL NEUTRALIZE UNREACTED PREPOLYMER.
Neutralizing Agent:10% AMMONIA SOLUTION
====================== Handling and Storage ======================
Handling and Storage Precautions:STORAGE TEMPERATURES SHOULD NOT EXCEED
75F TO PREVENT PREMATURE POLYMERIZATION OF THE PRODUCT.
Other Precautions:AVOID CONTACT WITH SKIN AND EYES.
============= Exposure Controls/Personal Protection =============
Respiratory Protection:NONE REQUIRED DURING CAST APPLICATION. DURING
CAST REMOVAL USE NIOSH/MSHA APPROVED RESPIRATORS FOR DUST IF
CONCENTRATION EXCEEDS THE TLV FOR NUISANCE DUST.
Ventilation:NORMAL MECHANICAL VENTILATION DURING CAST APPLICATION.
RECOMMEND LOCAL EXHAUST DURING CAST REMOVAL.
Protective Gloves:VINYL OR RUBBER GLOVES
Eye Protection:SAFETY GOGGLES WITH SIDE SHIELD.
Other Protective Equipment:NONE SPECIFIED BY MANUFACTURER.
Work Hygienic Practices:WASH HANDS BEFORE EATING OR SMOKING OR USING
THE WAS ROOM. LAUNDER CONTAMINATED CLOTHING BEFORE REUSE.
Supplemental Safety and Health
THE FIBERGLASS SUBSTRATE IS A LOW DUST/FIBER RELEASING MATERIAL. FREE
FIBERGLASS DUST PARTICLES ARE NOT EXPECTED TO BE RELEASED AS THE
SUBSTRATE IS BOUND BY THE PREPOLYMER.
================== Physical/Chemical Properties ==================
HCC:N1
Boiling Pt:B.P. Text:392F,200C
Vapor Pres:NIL
Spec Gravity:1.23-PREPOLYMER
Solubility in Water:REACTS
Appearance and Odor:4 YDX3 IN BANDAGE (FIBERGLASS SUBSTRATE COATED WITH
A POLYURETHANE RESIN.
Percent Volatiles by Volume:NIL
================= Stability and Reactivity Data =================
Stability Indicator/Materials to Avoid:NO
WATER, STRONG ALKALI, ALCOHOLS, METAL COMPOUNDS, SURFACE ACTIVE AGENTS.
Stability Condition to Avoid:HIGH TEMPERATURES, SPARKS, AND OPEN FLAMES
Hazardous Decomposition Products:CARBON DIOXIDE & CARBON DIOXIDE,
NITROGEN OXIDES AND ISOCYANATE VAPORS.
Conditions to Avoid Polymerization:POLYMERIZATION MAY OCCUR IF MATERIAL
IS HEATED FOR LONG PERIODS.
==================== Disposal Considerations ====================
Waste Disposal Methods:DISPOSAL SHOULD BE DONE IN ACCORDANCE WITH
FEDERAL,STATE AND LOCAL REGULATIONS.HARDENED CAST MATERIAL IS NOT
CLASSIFIED AS A HAZARDOUS WASTE AND MAY BE DISPOSED OF IN AN
ORDINARY LANDFILL.
Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.
*** END OF RECORD *** |
|