===================== Product Identification =====================
MSDS NAME:IRON CALIBRATOR, 790056901
NIIN:00N011797
MSDS Number: BJHYF
=== Responsible Party ===
Company:E I DU PONT DE NEMOURS, BIOMEDICAL PRODUCTS DEPT
Address:1007 MARKET ST
City:WILMINGTON
State:DE
ZIP:19898
Country:US
Info Phone Num:302-992-4132
Emergency Phone Num:800-441-3637
Preparer's Name:KEN WOODLIN
CAGE:B0589
=== Contractor Identification ===
Company:DUPONT E I DE NEMOURS AND CO INC, POLYMER PRODUCT-TEFLON
CO.
Address:1007 MARKET ST
Box:City:WILMINGTON
State:DE
ZIP:19898
Country:US
Phone:800-523-0372/346-4748
CAGE:9V583
Company:E I DU PONT DE NEMOURS & CO
Address:RAKETSTRAAT, 100, RUE DE LA FUSEE
City:BRUSSEL
Country:BE
Phone:32-(0)15-401.505
CAGE:B0589
============= Composition/Information on Ingredients =============
Name:HYDROGEN CHLORIDE (HYDROCHLORIC ACID) (SARA III)
CAS:7647-01-0
RTECS #:MW4025000
OSHA PEL:C 5 PPM
ACGIH TLV:C 5 PPM; 9192
EPA Rpt Qty:5000 LBS
DOT Rpt Qty:5000 LBS
Name:IRON (DISSOLVED WIRE); CAS AND RTECS ARE FOR IRON, ION
(FE2+).
CAS:15438-31-0
Name:NITRIC ACID (SARA III)
CAS:7697-37-2
RTECS #:QU5775000
OSHA PEL:2 PPM/4 STEL
ACGIH TLV:2 PPM/4 STEL; 9192
EPA Rpt Qty:1000 LBS
DOT Rpt Qty:1000 LBS
Name:MATLS TO AVOID/SUPP DATA:OR VINYL ACETATE.THE FOLLOWING
IGNITE W/HCL:FLUORINE,CESIUM CARBIDE,CESIUM ACETYLIDE,URANIUM
RTECS #:9999999ZZ
RTECS #:9999999ZZ
Name:ALUMINUM,CALCIUM PHOSPHIDE.REACTS W/METALS TO PRODUCE
HYDROGEN GAS.DECOMPOSES DOWCIL 100.NITRIC ACID IS INCOMPATIBLE W/
RTECS #:9999999ZZ
Name:METALLIC POWDERS,CARBIDES,SULFIDES,TURPENTINE,AND CYANIDES.
RTECS #:9999999ZZ
===================== Hazards Identification =====================
LD50 LC50 Mixture:LD50:(ORAL)900 MG/KG (RABBIT)
Routes of Entry: Inhalation:YES Skin:NO Ingestion:NO
Reports of Carcinogenicity:NTP:NO IARC:NO OSHA:NO
Health Hazards Acute and Chronic:INHAL:SOLUTION VAPORS MAY CAUSE
IRRITATION.SKIN:NO ADVERSE EFFECTS EXPECTED.EYE:VAPORS MAY BE
IRRITATING TO EYES.LIQUID IN EYE MAY CAUSE IRRITATION WITH
CORROSION IF NOT RINSED IMMEDIATELY.INGEST:SOLU TION MAY CAUSE
IRRITATION OF MOUTH,THROAT AND ESOPHAGUS.MAY CAUSE GASTRIC DISTRESS
UPON INGEST.TARGET ORGAN:EYES.
Explanation of Carcinogenicity:NOT RELEVANT.
Effects of Overexposure:SEE HEALTH HAZARDS.
Medical Cond Aggravated by Exposure:NO INFORMATION FOUND FOR THIS
CONCENTRATION.
======================= First Aid Measures =======================
First Aid:INHAL:REMOVE TO FRESH AIR.IF NOT BREATHING,GIVE ARTF
RESP,PREFERABLY MOUTH-TO-MOUTH.IF BREATHING IS DIFFICULT,GIVE
OXYGEN.CALL MD.SKIN:COMPOUND IS NOT LIKELY TO BE HAZ,BUT CLEANSING
THE SKIN AFTER USE IS ADVISABLE.EYE:IMMED FLUSH WITH PLENTY OF
WATER FOR AT LEAST 15 MINUTES.CALL MD.INGEST:DO NOT INDUCE
VOMIT.GIVE LARGE QUANTITIES OF WATER.NEVER GIVE ANYTHING BY MOUTH
TO UNCON PERSON.CALL MD.
===================== Fire Fighting Measures =====================
Extinguishing Media:WATER, WATER SPRAY, WATER FOG, CHEMICAL FOAM,
"ALCOHOL" FOAM, DRY POWDER (SAND OR MET-L-X), DRY CHEMICAL, C0*2.
Fire Fighting Procedures:EVACUATE PERSONNEL TO A SAFE AREA. KEEP
PERSONNEL REMOVED & UPWIND OF FIRE. WEAR NIOSH/MSHA APPROVED
PRESSURE DEMAND SCBA AND FULL PROTECTIVE EQUIPMENT.
Unusual Fire/Explosion Hazard:HAZ GASES PROD IN FIRE ARE HYDROGEN
CHLORIDE.CONT W/COMMON METALS PROD HYDROGEN GAS WHICH MAY FORM
EXPLO MIX W/AIR.THERMAL DECOMP MAY INCL HCL&PHOSGENE.
================== Accidental Release Measures ==================
Spill Release Procedures:REVIEW FIRE&EXPLOSION HAZARDS&SAFETY
PRECAUTIONS BEFORE CLEAN UP.USE APPROPRIATE PERSONAL PROTECTIVE
EQUIPMENT DURING CLEAN UP.ABSORB ON HAZORB(R)PILLOWS OR OTHER
ABSORBENT;SEAL IN PLASTIC BAG;LABEL.D ISPOSE PER LOCAL GUIDELINES.
Neutralizing Agent:NONE SPECIFIED BY MANUFACTURER.
====================== Handling and Storage ======================
Handling and Storage Precautions:AVOID BRTH VAP/MIST.AVOID CONT
W/EYES.WASH THOROUGHLY AFTER HNDL.USE ONLY W/ADEQ VENT.DO NOT MIX
W/COMMON METALS,ETC.FOR MORE INFO,REFER TO INSERT SHT
Other Precautions:SEE HAZARDOUS REACTIVITY SECTION.NO SMOKING IN AREA
OF USE.DO NOT USE IN THE GENERAL VICINITY OF ARC WELDING,OPEN
FLAMES OR HOT SURFACES.HEAT&/OR UV RADIATION MAY CAUSE THE
FORMATION OF HCL&/OR PHOSGE NE .
============= Exposure Controls/Personal Protection =============
Respiratory Protection:NIOSH/MSHA APPROVED RESPIRATOR APPROPRIATE FOR
EXPOSURE OF CONCERN .
Ventilation:USE ADEQUATE VENTILATION.CONSULT LOCAL SAFETY/HEALTH
AUTHORITIES IF ADDITIONAL GUIDANCE IS NECESSARY .
Protective Gloves:IMPERVIOUS GLOVES .
Eye Protection:CHEM WORK GOGGLES,FULL LENGTH FACESHIELD
Other Protective Equipment:RUBBER APRON.
Work Hygienic Practices:WASH THOROUGHLY AFTER HANDLING.
Supplemental Safety and Health
MATLS TO AVOID:TETRANITRIDE,SODIUM,POTASSIUM PERMANGANATE,SULFURIC
ACID,PERCHLORIC ACID.FOLLOWING CAUSE INCREASED TEMP&PRESSURE W/HCL
IN CLOSED CONT:ACETIC ANHYDRIDE,2-AMINOETHANOL,28% AMMONIA,CHLOROS
ULFONIC
ACID,ETHYLENEDIAMINE,ETHYLENEIMINE,OLEUM,PROPIOLACTONE(BETA-),PROPY
LENE OXIDE,SODIUM HYDROXIDE, (SEE INGRED 4)
================== Physical/Chemical Properties ==================
Boiling Pt:B.P. Text:212F,100C
Melt/Freeze Pt:M.P/F.P Text:32.0F,0.0C
Vapor Pres: 20 @ 25C
Vapor Density:1.27
Spec Gravity:1.00
pH:1.45
Evaporation Rate & Reference:>1 (BUTYL ACETATE = 1.0)
Solubility in Water:AQUEOUS
Appearance and Odor:CLEAR COLORLESS LIQUID, PUNGENT ODOR.
================= Stability and Reactivity Data =================
Stability Indicator/Materials to Avoid:NO
MAY REACT W/COMBUST/FLAMM MATL.THE FOLLOWING REACT EXPLO
W/HCL:ALCOHOLIC HYDROGEN CYANIDE,TETRASELENIUM (SEE SUPP DATA)
Stability Condition to Avoid:UNSTABLE WITH HEAT.
Hazardous Decomposition Products:DECOMP BY RXN W/MOST METALS. HAZARDOUS
GASES PRODUCED ARE HYDROGEN CHLORIDE GAS AND OXIDES OF NITROGEN.
PHOSGENE .
==================== Disposal Considerations ====================
Waste Disposal Methods:WEAR CHEM GOGGLES, RUBBER APRON & RUBBER GLOVES.
ADJUST PH TO 6-9 WITH SODIUM CARBONATE OR SODIUM BICARBONATE. FLUSH
TO ACID DRAIN WITH PLENTY OF WATER. DISPOSE PER LOCAL GUIDELINES.
Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.
*** END OF RECORD *** |
|